Products / Rosemount Analytical (Emerson) / SoluComp II Process Analyzer
Rosemount Analytical (Emerson) SoluComp II Process Analyzer

Rosemount 1055-01-10-20-30 Dual-Input Analytical Transmitter – SoluComp II Process Analyzer

Model: 1055-01-10-20-30

Brand Rosemount Analytical (Emerson)
Series SoluComp II Process Analyzer
Model 1055-01-10-20-30
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Rosemount 1055-01-10-20-30 Dual-Input Analytical Transmitter – SoluComp II Process Analyzer

When a process analyzer fails mid-production, the cost is rarely just the hardware. For facilities running continuous pH, conductivity, or dissolved oxygen monitoring, an unplanned transmitter outage can trigger batch rejection, regulatory non-compliance, and unscheduled line shutdowns. The Rosemount 1055-01-10-20-30 SoluComp II is a field-proven dual-input analytical transmitter widely deployed across water treatment, chemical processing, pharmaceutical manufacturing, and power generation. Sourcing a verified replacement unit on short notice is not straightforward. DriveKNMS maintains physical inventory of this model to support facilities that cannot afford extended lead times from standard distribution channels.

Technical Specifications

Parameter Detail
Manufacturer Rosemount Analytical (Emerson)
Model / Part Number 1055-01-10-20-30
Series SoluComp II (1055)
Instrument Type Dual-Input Analytical Transmitter
Measurement Parameters pH, ORP, Conductivity, Dissolved Oxygen (configuration-dependent per option codes)
Output Signal 4–20 mA HART (configuration-dependent)
Display Backlit LCD, dual-channel readout
Enclosure Rating IP65 / NEMA 4X
Power Supply 100–240 VAC, 50/60 Hz
Country of Origin United States
Current Production Status Active – Critical spare availability may vary by region and distributor lead time

Note: Option codes embedded in the part number (01-10-20-30) define specific hardware configurations. Verify compatibility with your existing sensor and control system before ordering. DriveKNMS technical staff can assist with cross-referencing.

Protecting Process Continuity: Why Stocking the 1055-01-10-20-30 Matters

The Rosemount SoluComp II platform has been a standard in analytical measurement for over two decades. Many facilities that commissioned their process control infrastructure in the 2000s and early 2010s built their sensor networks around this transmitter family. While Emerson continues to support the 1055 series, regional distributor stock levels fluctuate, and standard lead times from authorized channels can run 8–16 weeks for specific option-code configurations.

For a water treatment plant running continuous effluent monitoring, or a pharmaceutical facility under FDA 21 CFR Part 11 compliance requirements, a 16-week wait for a replacement transmitter is operationally unacceptable. The practical answer is not to wait for a failure event — it is to hold a verified spare on-site or with a reliable third-party supplier who can ship within days.

Facilities managing aging DCS infrastructure — including systems built around Emerson DeltaV, Honeywell Experion, or ABB 800xA — frequently rely on the 1055 series as a front-end measurement node. Replacing the transmitter with a newer-generation model often requires reconfiguration of HART device descriptors, loop calibration, and in some cases, DCS database updates. The cost of that engineering work routinely exceeds the cost of the transmitter itself by a factor of three to five. Maintaining like-for-like spares eliminates that overhead entirely.

A structured spare parts strategy for analytical instrumentation should account for: mean time between failures for transmitters in your specific process environment; the number of identical units deployed across the facility; and the realistic lead time from your current supply chain. For high-criticality loops — effluent discharge, boiler feedwater chemistry, sterile process monitoring — a minimum of one on-hand spare per five deployed units is a defensible starting position.

Condition and Reliability Assurance

Every Rosemount 1055-01-10-20-30 unit shipped by DriveKNMS passes a structured five-stage inspection protocol before dispatch:

  • Visual and mechanical inspection: Enclosure integrity, terminal block condition, display glass, and connector seating are checked against OEM acceptance criteria.
  • Electrolytic capacitor assessment: Internal capacitors are inspected for signs of bulging, electrolyte leakage, or ESR drift — a primary failure mode in transmitters that have been in storage or light-duty service for extended periods.
  • Firmware version verification: Installed firmware is documented and compared against known stable releases for the 1055 platform. Units with corrupted or non-standard firmware are quarantined.
  • Terminal and pin corrosion check: All I/O terminals, HART communication pins, and power input contacts are inspected under magnification and cleaned where necessary.
  • Functional power-on test: Units are powered and verified to reach normal operating state, with display output and analog output loop confirmed active.

Units that do not pass all five stages are not offered for sale. Condition grade is documented and disclosed at the time of quotation.

Key Features for System Maintenance

  • Drop-in replacement: The 1055-01-10-20-30 installs directly into existing panel cutouts and conduit entries designed for the SoluComp II form factor. No mechanical modification required.
  • No reprogramming required: HART device configuration is retained in the transmitter. When replacing a failed unit with an identical part number, sensor calibration data and alarm setpoints can be transferred via HART communicator without DCS engineering involvement.
  • Avoids engineering rework costs: Substituting a different transmitter model — even within the Emerson portfolio — typically triggers a management of change (MOC) process, loop documentation updates, and functional safety review. Like-for-like replacement with the same part number bypasses all of that.
  • Supports long-term asset life extension: Facilities that maintain a verified spare inventory for their analytical transmitter fleet can realistically extend the operational life of their measurement infrastructure by 7–10 years beyond what would otherwise be forced by parts unavailability.

Frequently Asked Questions

What warranty applies to units purchased from DriveKNMS?
All units carry a 90-day functional warranty covering failure under normal operating conditions. Extended warranty terms are available on request for volume orders.

How do I confirm the unit is new or in acceptable refurbished condition?
Condition grade (new surplus, tested refurbished, or used-tested) is stated explicitly in the quotation. We do not ship units without a documented inspection record. If you require a new-in-box unit specifically, confirm this requirement at the time of inquiry and we will advise on availability.

Can DriveKNMS supply multiple units for a long-term spare parts program?
Yes. We work with maintenance and reliability teams to structure multi-unit procurement for critical spare inventories. Contact us to discuss quantity, lead time, and pricing for program-based purchasing.

Is the part number configuration compatible with my existing sensors?
The option codes in the part number (1055-01-10-20-30) define the input configuration. Our technical team can cross-reference your existing sensor types and loop documentation to confirm compatibility before you commit to a purchase.

WhatsApp Prefilled Inquiry Email [email protected] Phone +86 18359293191 Top Back To Top