Products / Integral Solutions / QPS-1050 Series
Integral Solutions QPS-1050 Series

Integral Solutions QPS-1050 Series Modules: QST-2002 Input Module —

Model: QPS-1050 QST-2002

Brand Integral Solutions
Series QPS-1050 Series
Model QPS-1050 QST-2002
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Integral Solutions QPS-1050 Series: Comprehensive Module Range and Technical Overview

The Integral Solutions QPS-1050 series represents a mature, field-proven distributed control system (DCS) platform with documented deployment across global heavy industry sectors including petrochemical refining, nuclear power generation, offshore oil & gas processing, and large-scale chemical manufacturing. Its modular backplane architecture allows mixed I/O configurations within a single rack, a design characteristic that made it a preferred platform for brownfield expansions throughout the 1990s and 2000s. Installed base density remains high in facilities operating under long capital replacement cycles, making spare parts availability a critical operational requirement for maintenance engineers and reliability teams worldwide.

The Evolution of QPS-1050 Architecture

The QPS-1050 platform was introduced as a rack-based modular controller system designed around a proprietary high-speed backplane bus. Early revisions (Rev A/B) used parallel bus communication between the CPU module and I/O cards, with a maximum rack capacity of 16 slots. Mid-generation revisions introduced redundant bus arbitration and hot-swap capability for select module types, significantly improving mean time to repair (MTTR) in continuous-process environments.

The QST-2xxx sub-series (Signal Termination / Input modules) was introduced to standardize field wiring termination, separating signal conditioning from the main I/O logic board. This two-board architecture — a termination assembly (TA) paired with an I/O module — became the defining structural characteristic of the QPS-1050 I/O subsystem. Compatibility between TA generations and I/O module firmware revisions is a known integration constraint; mismatched revisions can result in channel faults or loss of HART communication on analog inputs.

As the platform entered its end-of-active-production phase, Integral Solutions released migration guides toward the QPS-2100 and QPS-3000 series. However, the installed base of QPS-1050 systems in facilities with 20+ year operational horizons means that demand for original replacement modules — particularly CPU, analog I/O, and communication adapter cards — remains commercially significant.

QPS-1050 Full Catalog & Functionalities (SKU List)

The following SKUs represent verified components within the QPS-1050 platform. Modules are classified by functional category.

Controller / CPU Modules

  • QPS-1050-CPU1: Primary controller module, single-processor, 32MB RAM, RS-232/RS-485 comm ports
  • QPS-1050-CPU2: Redundant controller module, hot-standby capable, paired with CPU1 in fault-tolerant configurations
  • QPS-1050-CPU3: Enhanced CPU with expanded memory (64MB) and Ethernet port for DCS network integration

Analog Input Modules

  • QST-2001: 8-channel analog input, 4–20 mA, non-HART, single-ended configuration
  • QST-2002: 8-channel analog input module, 4–20 mA with HART pass-through, differential inputs
  • QST-2003: 16-channel analog input, 4–20 mA, multiplexed, high-density rack applications
  • QST-2004: 8-channel thermocouple input module, types J/K/T/E/R/S/B, cold junction compensated
  • QST-2005: 8-channel RTD input module, PT100/PT1000, 2/3/4-wire selectable per channel

Analog Output Modules

  • QST-2010: 8-channel analog output, 4–20 mA, 750-ohm max load, HART-capable
  • QST-2011: 4-channel analog output, high-accuracy (0.05% FS), for precision control loops

Digital Input Modules

  • QST-2020: 32-channel digital input, 24 VDC, sink/source configurable, group isolated
  • QST-2021: 16-channel digital input, 120 VAC, optically isolated, for field device interfacing
  • QST-2022: 32-channel digital input, 48 VDC, high-speed pulse counting capable

Digital Output Modules

  • QST-2030: 16-channel digital output, 24 VDC, 0.5A per channel, short-circuit protected
  • QST-2031: 8-channel relay output module, SPDT contacts, 5A/250VAC rated

Communication Adapter Modules

  • QPS-1050-COMM1: PROFIBUS DP adapter, slave mode, up to 12 Mbps, DIN rail mountable
  • QPS-1050-COMM2: Modbus RTU/TCP gateway module, dual-port Ethernet, configurable baud rates
  • QPS-1050-COMM3: Foundation Fieldbus H1 interface module, 31.25 kbps, segment-powered

Power Supply Modules

  • QPS-1050-PS1: 24 VDC rack power supply, 10A output, 85–264 VAC input range
  • QPS-1050-PS2: Redundant power supply module, hot-swap, paired with PS1 for N+1 redundancy

Sourcing Hard-to-Find & Obsolete QPS-1050 Parts

The QPS-1050 series has been classified as end-of-active-production by Integral Solutions. Factory new stock is no longer available through standard distribution channels. DriveKNMS maintains a dedicated inventory program for QPS-1050 platform components, sourced through controlled decommissioning projects, authorized surplus channels, and long-term storage facilities.

Quality Control for the QPS-1050 Range

QPS-1050 modules present specific test challenges due to their proprietary backplane bus protocol and multi-board I/O architecture. DriveKNMS applies a structured test protocol for all QPS-1050 inventory:

  • Backplane Communication Verification: Each module is seated in a live QPS-1050 test rack and polled via the native backplane protocol to confirm register-level communication integrity.
  • Channel-Level I/O Functional Test: All analog input channels (including QST-2002) are stimulated with calibrated 4–20 mA signals across the full range; output accuracy is verified against factory tolerance (±0.1% FS).
  • HART Communication Test: For HART-capable modules (QST-2002, QST-2010), HART pass-through is verified using a HART communicator to confirm device descriptor read/write capability.
  • Firmware Revision Logging: Module firmware version is recorded and cross-referenced against known compatibility matrices for the target rack revision.
  • Visual and Component Inspection: PCB inspection for capacitor degradation, corrosion, and connector pin integrity — common failure modes in modules from long-term storage or high-humidity environments.
  • Burn-In Cycle: Modules are powered for a minimum 24-hour burn-in period under load to screen for latent component failures prior to shipment.
WhatsApp Prefilled Inquiry Email [email protected] Phone +86 18359293191 Top Back To Top