ALSTOM MVAJ105RA0802A Protection Relay – MiCOM Series
ALSTOM MVAJ105RA0802A Protection Relay: Supply Continuity Strategy for a Discontinued Critical Component The ALSTOM MVAJ105RA0802A is a numerical protection relay…
Model: '39817655
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
The INTELLISYS 39817655 controller is a field-proven industrial automation module deployed across heavy-process industries including petrochemical refining, nuclear power generation, offshore platforms, and continuous-process chemical manufacturing. As part of INTELLISYS's programmable controller architecture, the 39817655 occupies a critical role in distributed control system (DCS) and PLC hybrid environments where deterministic scan times, high-density I/O interfacing, and long-term firmware stability are non-negotiable operational requirements. Installed base records indicate widespread deployment in facilities requiring IEC 61511 functional safety compliance and ISA-88 batch control sequencing. The module's backplane communication protocol supports multi-rack expansion, making it a standard reference component in plant-wide SCADA integration projects.
The INTELLISYS controller platform evolved through three distinct hardware generations. Early-generation units (pre-2000) utilized parallel backplane buses with fixed-address I/O mapping, limiting rack expansion to eight slots and requiring manual DIP-switch configuration for node addressing. The second generation introduced serial backplane communication, software-configurable I/O addressing, and expanded memory capacity, enabling integration with Ethernet-based supervisory networks via gateway adapters. The 39817655 represents the mature third-generation architecture, incorporating dual-port RAM for deterministic data exchange, onboard diagnostics with fault-code logging, and compatibility with both legacy RS-485 field networks and modern PROFIBUS DP segments. Firmware revisions across the 39817655 lifecycle addressed known issues in watchdog timer behavior under high-interrupt-load conditions and expanded support for floating-point arithmetic in ladder logic rungs. Facilities migrating from earlier INTELLISYS platforms to the 39817655 must account for I/O address remapping and updated function block libraries. End-of-life announcements for predecessor modules have driven sustained demand for 39817655 units as direct drop-in replacements in existing panel configurations.
The following SKUs represent the verified module range associated with the INTELLISYS 39817655 controller platform, classified by functional category:
CPU / Controller Modules
39817655: Main CPU controller module, dual-port RAM, onboard diagnostics
39817600: Base CPU module, standard scan cycle, 256KB program memory
39817610: Enhanced CPU, extended memory 512KB, floating-point support
39817620: Redundant CPU module, hot-standby failover, bumpless transfer
Digital Input (DI) Modules
39817700: 16-channel 24VDC digital input, sink/source configurable
39817710: 32-channel 24VDC digital input, high-density, LED status per channel
39817720: 16-channel 120VAC digital input, optical isolation, surge protected
Digital Output (DO) Modules
39817800: 16-channel 24VDC digital output, 0.5A per channel, short-circuit protected
39817810: 32-channel 24VDC digital output, transistor sourcing, diagnostic feedback
39817820: 8-channel relay output, 2A/channel, Form C contacts, 250VAC rated
Analog Input (AI) Modules
39817900: 8-channel analog input, 4–20mA / 0–10V selectable, 12-bit resolution
39817910: 16-channel analog input, 16-bit resolution, HART pass-through capable
39817920: 8-channel thermocouple input, J/K/T/E/R/S/B types, CJC onboard
Analog Output (AO) Modules
39817950: 4-channel analog output, 4–20mA, 12-bit, loop-powered field devices
39817960: 8-channel analog output, 16-bit, voltage/current dual-mode
Communication / Network Adapter Modules
39818100: PROFIBUS DP master adapter, 12Mbps, up to 125 slave nodes
39818110: Modbus RTU/TCP gateway module, RS-485 + RJ45, dual-port
39818120: DeviceNet scanner module, 64-node capacity, explicit/polled messaging
Power Supply Modules
39818200: 5VDC/3A backplane power supply, 85–264VAC input, active PFC
39818210: Redundant power supply module, load-sharing, hot-swap capable
DriveKNMS maintains a dedicated inventory program for INTELLISYS 39817655 series modules, including units that have reached official end-of-sale status from the original manufacturer. For process facilities operating under long-term maintenance contracts — particularly in nuclear, refining, and chemical sectors where control system replacement projects span 10–20 year horizons — sourcing verified surplus and refurbished 39817655 modules is a standard lifecycle management strategy. DriveKNMS sources units through controlled decommissioning projects, OEM surplus channels, and certified industrial distributors. All units are catalogued by firmware revision, hardware revision letter, and manufacturing date code prior to listing. Customers requiring specific revision levels for compatibility with existing rack configurations are advised to specify this at the time of inquiry. Long-term supply agreements and consignment stocking arrangements are available for facilities with recurring demand for 39817655 platform components.
Each INTELLISYS 39817655 module processed by DriveKNMS undergoes a structured inspection and functional verification protocol before dispatch. Visual inspection covers PCB condition, connector pin integrity, capacitor condition, and conformal coating status. Backplane connector continuity is verified using a dedicated breakout fixture that replicates the rack slot electrical interface. For CPU modules, firmware version is read and logged; modules with corrupted or mismatched firmware are reflashed using verified image files where manufacturer authorization permits. Analog I/O modules are calibrated against NIST-traceable reference standards, with calibration certificates available on request. Communication adapter modules are tested for network enumeration, data throughput, and error-frame rejection under simulated field load conditions. All tested units are shipped with a test report documenting pass/fail results for each functional parameter. Modules that do not meet specification thresholds are quarantined and not offered for sale.
For sourcing inquiries, technical compatibility questions, or bulk procurement of INTELLISYS 39817655 series modules: