Product Details And Specifications

Allen-Bradley MicroLogix 1500 Series Technical Notes

The Allen-Bradley MicroLogix 1500 (catalog prefix: 1764) is a mid-range programmable logic controller platform developed by Rockwell Automation. It has achieved widespread deployment across global heavy industry sectors including petrochemical refining, water treatment facilities, pulp and paper manufacturing, automotive assembly lines, and nuclear auxiliary systems. Its modular architecture — separating the base unit, processor, and expansion I/O — made it a preferred choice for applications requiring deterministic scan times, compact panel footprint, and native integration with Rockwell's RSLogix 500 programming environment. Installed base estimates place the MicroLogix 1500 among the most widely maintained legacy PLC platforms in North America, Latin America, and Southeast Asia, with active spare parts demand continuing well into the 2020s despite the platform's end-of-life designation.

The Evolution of MicroLogix 1500 Architecture

The MicroLogix 1500 was introduced in the late 1990s as a successor to the MicroLogix 1000, addressing demand for higher I/O density and expanded memory in a compact form factor. The platform is built around two processor variants — the LRP (1764-LRP) and LSP (1764-LSP) — which differ in communication capability and instruction set depth. Early revisions supported only DH-485 and RS-232 communications; later hardware revisions added EtherNet/IP capability via the 1764-LRP processor, enabling integration with modern SCADA and MES architectures without replacing the base hardware.

Memory expansion was addressed through the 1764-MM1 (8 KB) and 1764-MM2 (16 KB) plug-in memory modules, allowing program storage to be extended beyond the processor's onboard capacity. The platform's expansion I/O system uses 1762-series modules (MicroLogix 1200 compatible), providing cross-platform I/O reuse. Rockwell Automation announced end-of-life for the MicroLogix 1500 series, with last-time-buy periods now closed, making third-party sourcing the primary procurement channel for maintenance and replacement units. Migration paths recommended by Rockwell include the Micro820 and Micro850 controllers under the Connected Components Workbench environment, though direct program conversion requires manual re-engineering.

MicroLogix 1500 Full Catalog & Functionalities (SKU List)

Processors

  • 1764-LRP: MicroLogix 1500 processor with EtherNet/IP, DH-485, RS-232; 14 KB user memory
  • 1764-LSP: MicroLogix 1500 processor with DH-485 and RS-232 only; 10 KB user memory

Memory Modules

  • 1764-MM1: 8 KB plug-in memory module for MicroLogix 1500 processor program backup and transfer
  • 1764-MM2: 16 KB plug-in memory module; doubles onboard storage for large ladder logic programs

Base Units

  • 1764-24BWA: 24-point base unit; 120/240V AC input; relay output; includes 12 DC inputs, 6 AC inputs, 6 relay outputs
  • 1764-28BXB: 28-point base unit; 24V DC input/output; sourcing transistor outputs
  • 1764-24AWA: 24-point base unit; AC power supply; relay outputs; standard density I/O

Discrete Input Modules (1762-series expansion)

  • 1762-IQ8: 8-point 24V DC sinking/sourcing digital input module
  • 1762-IQ16: 16-point 24V DC digital input module; high-density discrete input expansion
  • 1762-IA8: 8-point 120V AC digital input module
  • 1762-IQ8OW6I: Combination module; 8 DC inputs, 6 isolated relay outputs

Discrete Output Modules (1762-series expansion)

  • 1762-OW8: 8-point relay output module; 240V AC / 24V DC rated contacts
  • 1762-OB16: 16-point 24V DC sourcing transistor output module
  • 1762-OA8: 8-point 120/240V AC triac output module

Analog Modules (1762-series expansion)

  • 1762-IF4: 4-channel analog input module; 0–10V / 4–20 mA selectable per channel
  • 1762-OF4: 4-channel analog output module; voltage and current output selectable
  • 1762-IF2OF2: 2-channel analog input / 2-channel analog output combination module

Communication & Specialty Modules

  • 1761-NET-ENI: EtherNet/IP interface adapter for MicroLogix controllers without native Ethernet
  • 1761-NET-AIC: Advanced interface converter; RS-232 to DH-485 protocol bridge

Quality Control for the MicroLogix 1500 Range

MicroLogix 1500 modules present specific test challenges due to their integrated backplane communication bus and processor-dependent memory addressing. DriveKNMS applies the following inspection protocol to all 1764-series and associated 1762-series units prior to shipment:

  • Visual inspection: PCB examination for capacitor degradation, corrosion on edge connectors, and physical damage to DIN rail mounting tabs.
  • Firmware revision verification: Processor units are powered and interrogated via RSLinx Classic to confirm hardware series and firmware revision, documented on the test certificate.
  • Memory module read/write test: 1764-MM1 and 1764-MM2 modules are tested by writing a known program image and verifying successful read-back on a live 1764-LRP processor.
  • I/O channel functional test: All discrete and analog I/O channels on 1762-series modules are exercised at rated voltage/current with pass/fail logging per channel.
  • Communication port test: RS-232 and DH-485 ports verified for signal integrity using protocol analyzer; EtherNet/IP port tested for link establishment and MSG instruction response on LRP units.
  • Burn-in period: Processor and memory module assemblies are powered continuously for a minimum of 24 hours under ambient temperature cycling before final packaging.