Allen-Bradley 1775 PLC-3 Modules: AB 1775-P3 Multi-Output Power Supply

Model: 1775-P3

Series Pending
Model 1775-P3
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley 1775 PLC-3 Series Technical Notes

The Allen-Bradley 1775 series, commercially designated as the PLC-3 platform, represents one of Rockwell Automation's foundational programmable logic controller architectures. Introduced in the late 1970s and deployed through the 1990s, the 1775/PLC-3 platform achieved deep penetration in continuous-process and batch-process industries including petrochemical refining, nuclear power generation, pulp and paper manufacturing, and large-scale chemical processing. Its modular backplane architecture, deterministic scan cycle, and robust I/O density made it the preferred controller for safety-critical and high-availability installations. Thousands of 1775-series chassis remain in active service globally, particularly in facilities where capital replacement cycles extend 20–30 years. Maintaining operational continuity for these installations requires access to verified spare parts, including the AB 1775-P3 Multi-Output Power Supply and the full range of associated CPU, I/O, communication, and memory modules.

The Evolution of 1775 Architecture

The 1775/PLC-3 architecture was designed around a parallel backplane bus that supported synchronous data transfer between the processor and I/O modules. Early deployments (circa 1979–1985) used the 1775-L1 processor with limited memory capacity and relied on discrete I/O modules for plant-floor interfacing. The introduction of the 1775-L2 and 1775-L3 processors expanded addressable memory and added support for structured text and function block programming constructs ahead of IEC 61131-3 standardization.

Communication capabilities evolved through the 1775-GA and 1775-KA adapters, enabling integration with Data Highway and Data Highway Plus networks — the precursors to modern EtherNet/IP architectures. By the mid-1990s, the 1775 platform was positioned as a legacy system, with Rockwell Automation directing new installations toward the ControlLogix (1756) and CompactLogix (1769) families. However, the installed base remained substantial, and Rockwell continued to supply spare parts through its authorized channel until the platform reached end-of-life (EOL) status. Post-EOL, third-party distributors and specialist suppliers such as DriveKNMS became the primary sourcing channel for 1775-series components. Compatibility between early and late 1775 revisions requires careful attention to firmware levels, backplane slot assignments, and power budget calculations — particularly when mixing module generations within a single chassis.

1775 Full Catalog & Functionalities (SKU List)

The following catalog covers verified Allen-Bradley 1775-series modules organized by functional category. Each entry reflects a distinct hardware SKU with a defined role within the PLC-3 platform architecture.

CPU / Processor Modules

  • 1775-L1: PLC-3 processor, 8K word user memory, early-generation baseline CPU.
  • 1775-L2: Enhanced PLC-3 processor, 16K word memory, expanded instruction set support.
  • 1775-L3: High-capacity PLC-3 processor, 32K word memory, structured data file support.

Power Supply Modules

  • 1775-P1: Single-output 5 VDC power supply for standard chassis configurations.
  • 1775-P2: Dual-output power supply, 5 VDC and 24 VDC, for mixed I/O chassis.
  • 1775-P3: Multi-output power supply; provides 5 VDC, ±15 VDC, and 24 VDC rails for high-density chassis.
  • 1775-P4: Redundant power supply module for high-availability chassis configurations.

Discrete I/O Modules

  • 1775-S4A: 16-point 120 VAC discrete input module, screw-terminal field wiring.
  • 1775-S4B: 16-point 120 VAC discrete output module, triac-switched, 0.5 A per point.
  • 1775-S4C: 16-point 24 VDC discrete input module, sinking/sourcing configurable.
  • 1775-S4D: 16-point 24 VDC discrete output module, transistor-switched.

Analog I/O Modules

  • 1775-A1: 4-channel analog input module, 4–20 mA / 0–10 VDC selectable range.
  • 1775-A2: 4-channel analog output module, 4–20 mA current loop output.

Communication Adapter Modules

  • 1775-GA: Data Highway adapter, enables PLC-3 integration with DH network at 57.6 kbps.
  • 1775-GAT: Data Highway Plus adapter, supports token-passing protocol at up to 230.4 kbps.
  • 1775-KA: Remote I/O adapter, links 1775 chassis to 1771 remote I/O scanner networks.

Memory Modules

  • 1775-MEA: 16K word EEPROM memory cartridge for program backup and transfer.
  • 1775-MED: 32K word EEPROM memory cartridge, compatible with 1775-L3 processor only.

Sourcing Hard-to-Find & Obsolete 1775 Parts

The Allen-Bradley 1775 series reached official end-of-life status, and Rockwell Automation no longer manufactures or provides factory repair services for these modules. For facilities operating PLC-3 installations, the sourcing of verified spare parts — including the 1775-P3, 1775-L3, and communication adapters — requires engagement with specialist distributors who maintain tested surplus inventory.

Quality Control for the 1775 Range

The 1775 platform uses a parallel backplane bus with strict timing requirements. Modules with degraded bus drivers or corrupted firmware can cause intermittent faults that are difficult to diagnose in the field. DriveKNMS applies a structured test protocol to all 1775-series modules prior to shipment:

  • Backplane bus signal integrity verification using oscilloscope measurement at defined test points.
  • Power rail output measurement for supply modules (1775-P1 through 1775-P4), confirming voltage regulation within ±2% of rated output under load.
  • Functional I/O scan test for discrete and analog modules using a dedicated 1775 test chassis.
  • Communication adapter handshake verification on live Data Highway and Data Highway Plus network segments.
  • Visual inspection for capacitor degradation, PCB corrosion, and connector pin integrity.
  • Firmware revision logging to confirm compatibility with target processor revision levels.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top