ABB TB842 3BSE022464R1 Modules - NDBU-95C 64008366D

Model: NDBU-95C 64008366D

Brand ABB
Model NDBU-95C 64008366D
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

ABB TB842 Series Technical Notes

The Evolution of TB842 Architecture

The S800 I/O system was introduced by ABB in the mid-1990s as the field I/O layer for the Advant OCS and later the AC800M DCS platform. The TB842 termination unit belongs to the first-generation S800 I/O hardware family, which established a standardized backplane bus (ModuleBus) for communication between I/O modules and the controller. Early S800 hardware (circa 1996–2002) used parallel ModuleBus architecture with dedicated termination boards per module type. The TB842 is compatible with AI810 (8-channel, 4–20 mA / 1–5 V) and AI820 (8-channel HART-enabled) analog input modules.

From 2003 onward, ABB introduced the S800 I/O L series with enhanced EMC shielding and extended temperature ratings, while maintaining backward compatibility with existing TB8xx termination units. The TB842 remained unchanged in its electrical interface, ensuring that field wiring installed in the 1990s could be retained during controller upgrades to AC800M v5.x and v6.x firmware generations. As of 2020, the S800 I/O hardware line entered a mature/end-of-active-development phase. ABB continues to supply spare parts and provide lifecycle extension support, but new installations are directed toward the S900 I/O platform. For existing plants, the TB842 remains a long-term maintenance item with a projected support horizon through 2030+ under ABB's Extended Lifecycle Program.

TB842 / S800 I/O Full Catalog & Functionalities (SKU List)

The following SKUs represent verified, commonly stocked modules within the ABB S800 I/O ecosystem. Each is compatible with the AC800M controller family and shares the ModuleBus backplane architecture.

Termination Units (TB8xx Series)

  • TB820 / 3BSE013208R1: ModuleBus Modem, single-slot termination for standard I/O modules
  • TB840 / 3BSE037760R1: Termination Unit for AI810, passive 8-ch analog input wiring board
  • TB842 / 3BSE022464R1: Termination Unit for AI810/AI820, field-side screw terminal block, DIN-rail mount
  • TB845 / 3BSE021437R1: Termination Unit for AO810/AO820, 8-ch analog output passive termination
  • TB846 / 3BSE022460R1: Termination Unit for DI810/DI811, 16-ch digital input passive wiring board
  • TB850 / 3BSE023607R1: Termination Unit for DO810/DO814, 16-ch digital output passive termination
  • TB851 / 3BSE023608R1: Termination Unit for DO815, relay output passive termination board
  • TB852 / 3BSE018161R1: Termination Unit for DI890/DO890, high-density I/O passive board

Analog Input Modules (AI8xx Series)

  • AI810 / 3BSE008516R1: 8-channel analog input, 4–20 mA / 1–5 V, single-ended, S800 ModuleBus
  • AI820 / 3BSE008544R1: 8-channel analog input with HART protocol support, 4–20 mA
  • AI830 / 3BSE008546R1: 8-channel thermocouple/RTD input, multi-type sensor support
  • AI835 / 3BSE008548R1: 8-channel RTD input, Pt100/Pt1000, 3-wire configuration

Analog Output Modules (AO8xx Series)

  • AO810 / 3BSE008522R1: 8-channel analog output, 4–20 mA, single-ended, S800 ModuleBus
  • AO820 / 3BSE008550R1: 8-channel analog output with HART protocol, 4–20 mA

Digital Input Modules (DI8xx Series)

  • DI810 / 3BSE008508R1: 16-channel digital input, 24 VDC, sink/source configurable
  • DI811 / 3BSE008510R1: 16-channel digital input, 120 VAC, optically isolated
  • DI814 / 3BSE008512R1: 16-channel digital input, 48 VDC, high-density format

Digital Output Modules (DO8xx Series)

  • DO810 / 3BSE008514R1: 16-channel digital output, 24 VDC, 0.5 A per channel
  • DO814 / 3BSE008518R1: 16-channel digital output, 24 VDC, high-current 2 A per channel
  • DO815 / 3BSE013258R1: 8-channel relay output, SPDT, 250 VAC / 5 A rated contacts

Quality Control for the TB842 / S800 I/O Range

Termination units such as the TB842 are passive assemblies; however, failure modes include corroded screw terminals, cracked PCB traces at field-wiring connection points, and degraded backplane connector pins from repeated module insertion cycles. DriveKNMS applies the following inspection protocol to all S800 I/O hardware prior to shipment:

  • Visual inspection of all 40-pin backplane connectors under 10× magnification for pin deformation or oxidation
  • Continuity verification across all field terminal blocks using calibrated milliohm meter (target: <0.5 Ω per terminal path)
  • Insulation resistance test between signal channels and chassis ground (minimum 100 MΩ at 500 VDC)
  • Dimensional check of DIN-rail mounting clips for retention force compliance
  • Functional loop test with paired AI810 module and AC800M simulator where test bench availability permits

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top