Beckhoff BK3120 DeviceNet Bus Coupler – Fieldbus Module
Beckhoff BK3120 is listed for Servo Drives RFQ review. Confirm quantity, condition and destination before quotation.
Model: EK1914
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.
The EK1xxx coupler family originated with the EK1100, a standard EtherCAT bus coupler introduced in the early 2000s as Beckhoff expanded its EtherCAT I/O ecosystem. The EK1100 provided the foundational E-bus segment interface but carried no safety logic. As functional safety requirements tightened under IEC 61508 Ed.2 (2010) and the proliferation of machinery directive 2006/42/EC, Beckhoff introduced the EK1960 TwinSAFE compact controller — a coupler-form-factor device capable of hosting safety programs locally. The EK1914 represents the next architectural step: a coupler that combines FSoE slave communication, local TwinSAFE logic execution, and mixed safe I/O (4 DI + 4 DO) in a single 12 mm housing. Compatibility considerations are significant for retrofit projects: EK1914 requires TwinCAT 3.1 Build 4022 or higher for TwinSAFE project integration, and FSoE master functionality must reside in a TwinSAFE controller (EK1960, EL6910, or CX-series with TF6910 license). Legacy EK1100-based segments can coexist on the same EtherCAT ring but cannot participate in the FSoE safety domain. Migration from relay-based SIS to EK1914-based architectures typically involves re-validation under IEC 61511-1 Clause 11 and updated FMEA documentation.
The following SKUs represent the verified Beckhoff EK1xxx coupler and related TwinSAFE terminal product range. Each entry reflects a distinct hardware function within the EtherCAT safety I/O architecture.
EK1100: Standard EtherCAT bus coupler, E-bus power supply, no safety logic, 2A E-bus current.
EK1101: EtherCAT coupler with ID switch for topology-based addressing in distributed cabinet layouts.
EK1110: EtherCAT extension, extends E-bus segment over EtherCAT infrastructure to remote I/O islands.
EK1122: 2-port EtherCAT junction coupler for star topology wiring without managed switches.
EK1521: EtherCAT coupler with single-mode fiber optic interface, 1310 nm, for electrically isolated long-distance segments.
EK1541: EtherCAT coupler with plastic optical fiber (POF) interface for short-range EMI-immune segments.
EK1818: EtherCAT coupler with 8 digital inputs and 8 digital outputs integrated, standard (non-safety) I/O.
EK1828: EtherCAT coupler with 8 digital outputs integrated, 24 VDC, 0.5 A per channel, standard I/O.
EK1914: EtherCAT coupler with 4 FSoE digital safety inputs + 4 FSoE digital safety outputs, TwinSAFE logic, SIL 3 / PLe.
EK1960: TwinSAFE compact controller, FSoE master/slave, up to 128 safety addresses, local safety program execution.
EL1904: 4-channel digital safety input terminal, FSoE, 24 VDC, IEC 61131-2 Type 3, SIL 3 / PLe.
EL2904: 4-channel digital safety output terminal, FSoE, 24 VDC / 0.5 A per channel, SIL 3 / PLe.
EL6910: TwinSAFE logic terminal, FSoE master, up to 128 connections, replaces EL6900 in new designs.
EL6900: TwinSAFE logic terminal (legacy), FSoE master, up to 63 connections, EOL — long-term spare support only.
EL1918: 8-channel digital safety input terminal, FSoE, 24 VDC, for high-density SIS panel designs.
EL2918: 8-channel digital safety output terminal, FSoE, 24 VDC / 0.5 A, for high-density actuator wiring.
EL1988: 8-channel digital input terminal, standard, 24 VDC, used alongside safety terminals for non-SIL diagnostics.
EK1501: EtherCAT coupler with multimode fiber optic interface for medium-distance segment isolation.
Q: How is condition confirmed before quotation?
A: Available condition, photos, test records and documentation are checked according to the requested model and sourcing channel before a formal RFQ response.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.