GE IC670 Series Modules – IC670MDL740

Model: IC670MDL740

Series IC670MDL740
Model IC670MDL740
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

GE IC670 Series Technical Notes

The GE IC670 series — commercially known as the GE Genius I/O system — represents one of the most widely deployed distributed I/O architectures in global heavy industry. Installed across petrochemical refineries, nuclear power facilities, offshore platforms, and continuous-process chemical plants, the IC670 platform operates as a field-level I/O subsystem interfacing with GE Series 90-70, Series 90-30, and PACSystems RX7i/RX3i controllers via the Genius Bus (a single-twisted-pair serial network at 153.6 kbps). Its rugged design, deterministic scan cycle, and fault-tolerant bus architecture have made it a long-term fixture in safety-critical environments where replacement cycles span 15–25 years.

The Evolution of IC670 Architecture

The IC670 platform was introduced by GE Fanuc Automation in the late 1980s as a distributed I/O extension for the Series 90-70 PLC. The architecture centers on the Genius Bus Controller (GBC), which manages up to 32 Genius I/O blocks per bus segment. Each block operates as an autonomous node, executing local I/O scanning independently of the host controller — a design that predates modern fieldbus standards (PROFIBUS, EtherNet/IP) by nearly a decade.

Key architectural milestones:

  • Generation 1 (1988–1995): Original IC670 blocks with fixed I/O configurations, DIP-switch addressing, and 24 VDC/120 VAC discrete I/O. No diagnostics beyond basic fault relay.
  • Generation 2 (1995–2005): Introduction of analog I/O blocks (IC670ALG), expanded diagnostic reporting, and compatibility with Series 90-30 via Bus Interface Units (BIU). Hot-standby redundancy configurations became supported.
  • Generation 3 / Transition Era (2005–present): GE Fanuc rebranded to GE Intelligent Platforms, then to Emerson Automation Solutions (2019). PACSystems RX7i/RX3i controllers maintain backward-compatible Genius Bus support via IC695GBC001 and IC694BEM331 gateway modules. No new IC670 hardware has been released since approximately 2010; the series is in sustained-availability / end-of-life status.

Compatibility note: IC670 blocks are not directly interchangeable with IC660 (Genius I/O predecessor) blocks without bus parameter reconfiguration. IC670 blocks require Genius Bus Controller firmware v4.0 or later for full diagnostic support.

IC670 Full Catalog & Functionalities (SKU List)

Discrete Output Modules

  • IC670MDL740: 12-output 120 VAC isolated discrete output block, 0.5A per point, Genius Bus node, field-replaceable terminal assembly.
  • IC670MDL741: 12-output 240 VAC discrete output block, 0.5A per point, surge-protected, DIN-rail or panel mount.
  • IC670MDL742: 12-output 24 VDC discrete output block, 1A per point, sinking configuration, short-circuit protected.
  • IC670MDL743: 12-output 24 VDC sourcing discrete output block, 1A per point, CE-marked, UL listed.
  • IC670MDL730: 16-output 24 VDC discrete output block, 0.5A per point, high-density configuration, Genius Bus addressable.

Discrete Input Modules

  • IC670MDL640: 16-input 24 VDC discrete input block, 2ms filter, Genius Bus node, LED status per point.
  • IC670MDL641: 16-input 120 VAC discrete input block, optical isolation, 8ms filter, panel or DIN mount.
  • IC670MDL642: 16-input 240 VAC discrete input block, optical isolation, CE/UL certified.
  • IC670MDL643: 8-input 120/240 VAC discrete input block, high-voltage isolated, used in motor control center applications.
  • IC670MDL630: 32-input 24 VDC high-density discrete input block, 1ms filter, compact footprint.

Analog I/O Modules

  • IC670ALG230: 4-channel analog voltage input block, ±10V / 0–10V selectable, 12-bit resolution, Genius Bus node.
  • IC670ALG240: 4-channel analog current input block, 4–20mA / 0–20mA, 12-bit resolution, loop-powered compatible.
  • IC670ALG320: 2-channel analog voltage output block, ±10V / 0–10V, 12-bit DAC, short-circuit protected.
  • IC670ALG330: 2-channel analog current output block, 4–20mA, 12-bit DAC, open-loop detection.
  • IC670ALG620: 6-channel thermocouple input block, J/K/T/E/R/S/B type selectable, cold-junction compensated, 14-bit resolution.

Bus Controllers & Interface Modules

  • IC670GBI001: Genius Bus Interface unit, connects IC670 blocks to non-Genius host controllers via RS-485 gateway protocol.
  • IC670PBI001: PROFIBUS-DP to Genius Bus bridge, enables IC670 I/O integration into third-party DCS environments.

Sourcing Hard-to-Find & Obsolete IC670 Parts

The IC670 series entered end-of-active-production status circa 2012. GE / Emerson no longer manufactures new IC670 hardware; OEM support is limited to software patches and documentation. For facilities operating IC670-based systems, the primary supply chain risk is hardware obsolescence — particularly for high-failure-rate components such as output relay blocks, analog input modules with aging ADC circuits, and Bus Controller units with degraded EEPROM.

Quality Control for the IC670 Range

IC670 modules present specific test challenges due to their integrated Genius Bus communication logic and backplane-less distributed architecture. DriveKNMS applies the following test protocol to all IC670 units prior to shipment:

  • Bus Communication Verification: Each block is connected to a live Genius Bus segment (153.6 kbps) and verified for correct node address response, data exchange, and fault reporting using a GE Series 90-70 or PACSystems RX7i test bench.
  • I/O Point Functional Test: All discrete I/O points are individually energized and verified against rated voltage/current specifications. Analog modules are calibrated against NIST-traceable reference standards (±0.1% accuracy).
  • Thermal Burn-In: Refurbished units undergo 48-hour powered burn-in at 45°C ambient to screen latent component failures.
  • Visual & Mechanical Inspection: Terminal blocks, connector pins, and housing integrity are inspected per IPC-A-610 Class 2 workmanship standards.
  • Firmware Version Check: Bus Controller and BIU units are verified for firmware revision compatibility with target host controller platforms.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top