GE IC695ETM001-CC Ethernet Interface Module – Obsolete PACSystems RX3i Spare Part
GE IC695ETM001-CC Ethernet Interface Module – Obsolete PACSystems RX3i Spare Part When a GE PACSystems RX3i Ethernet communication module fails,…
Model: IC695PBM300-CC
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
When a PROFIBUS master module fails in a GE PACSystems RX3i rack, the consequences extend far beyond a single card replacement. The IC695PBM300-CC sits at the communication backbone of distributed I/O networks that may span an entire production floor. A forced migration away from this architecture — driven solely by parts unavailability — typically triggers a full controls engineering project: new PLC platform selection, I/O rewiring, HMI reconfiguration, operator retraining, and production downtime measured in weeks. Conservative estimates for such a migration in a mid-size manufacturing facility run from USD $500,000 to over $2,000,000. A single verified spare unit of the IC695PBM300-CC eliminates that risk entirely.
DriveKNMS maintains sourced inventory of this discontinued module. Stock is finite and not replenishable from the original manufacturer.
| Parameter | Detail |
|---|---|
| Part Number | IC695PBM300-CC |
| Manufacturer | GE Automation (now Emerson Automation Solutions) |
| Series | PACSystems RX3i |
| Module Type | PROFIBUS DP Master (Class 1) |
| Bus Interface | Universal Backplane (RX3i) |
| PROFIBUS Standard | IEC 61158 / EN 50170 |
| Max DP Slaves | 125 per master |
| Country of Origin | United States |
| Manufacturer Status | Discontinued / Obsolete |
| Replacement Path | No direct OEM drop-in replacement available |
Note: Electrical parameters not listed here are not independently verified. We do not publish unconfirmed specifications. Contact us for datasheet documentation.
The GE PACSystems RX3i platform was widely deployed across process industries — oil & gas, automotive, food & beverage, and utilities — throughout the 2000s and 2010s. Many of these installations remain in active production today, running stable, validated control logic that plant engineers have no business case to replace.
The IC695PBM300-CC is the PROFIBUS master that connects the RX3i CPU to field devices: remote I/O racks, variable frequency drives, valve positioners, and instrumentation. There is no software-only workaround when this module fails. The PROFIBUS network goes silent. Production stops.
GE (Emerson) has not offered this module as a new production item for several years. Authorized distributor channels are exhausted. The secondary market — sourced, tested, and responsibly handled — is the only viable supply path for facilities that need to maintain this architecture without a multi-million dollar platform migration.
How to extend your PACSystems RX3i asset life by 5–10 years without a platform migration:
Facilities that treat legacy spare parts as a strategic asset rather than a procurement afterthought consistently achieve 7–10 additional years of productive life from installed automation infrastructure. The IC695PBM300-CC is a $X,XXX investment that protects a $X,000,000 production asset.
Every IC695PBM300-CC unit processed by DriveKNMS passes a structured 5-step inspection protocol before it is offered for sale. This protocol is designed specifically for the failure modes common to legacy industrial modules that have been in storage or removed from service.
Units are packaged in anti-static bags with foam protection and shipped with full documentation of the inspection findings.
Q: What warranty applies to a discontinued module like the IC695PBM300-CC?
A: DriveKNMS provides a 90-day warranty covering functional defects identified after installation. Given the obsolete status of this part, we recommend buyers treat the warranty period as a commissioning and burn-in window and maintain a cold spare thereafter.
Q: How do I confirm the unit is genuine and not counterfeit?
A: All units are sourced from documented industrial decommissioning projects or authorized secondary market channels. We provide the unit's serial number and firmware revision prior to shipment. Buyers are encouraged to verify the serial number format against GE/Emerson documentation.
Q: Should I buy more than one unit?
A: For any facility with more than one RX3i rack running PROFIBUS, maintaining at least two spare IC695PBM300-CC modules is a defensible risk management position. The module is no longer manufactured. Once current secondary market stock is exhausted, sourcing will become progressively more difficult and expensive. Procurement now, at known cost, is preferable to emergency sourcing under production pressure.
Q: Can this module work with PACSystems RX7i or RSTi-EP?
A: The IC695PBM300-CC is designed for the RX3i universal backplane. It is not compatible with RX7i VME-based racks or the RSTi-EP platform. Confirm your rack type before ordering.
© 2026 DriveKNMS. Status: DRAFT