Honeywell MasterLogic Modules: 2MLL-CH2B-CC

Model: 2MLL-CH2B-CC

Brand Honeywell
Series MasterLogic
Model 2MLL-CH2B-CC
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Honeywell MasterLogic Series Technical Notes

The 2MLL-CH2B-CC is a communications controller module within the MasterLogic chassis architecture, providing the backplane communication interface between the CPU and I/O subsystems. It is a field-proven component in safety-instrumented and process-control loops where deterministic data exchange is non-negotiable.

The Evolution of MasterLogic Architecture

The MasterLogic platform was introduced by Honeywell as a mid-to-high tier PLC solution bridging the gap between standalone relay-replacement PLCs and full DCS deployments. Early generations (ML-Series I) used proprietary backplane buses with fixed-slot addressing, limiting hot-swap capability. The second-generation architecture introduced the modular chassis design — including the 2MLL chassis family — with a high-speed serial backplane bus, enabling live module insertion without process interruption.

The 2MLL chassis (2-slot to 16-slot configurations) standardized the physical form factor across CPU, communications, analog I/O, digital I/O, and power supply modules. This generation introduced the CH2B-CC communications controller designation, which handles inter-module arbitration and external network gateway functions. Subsequent firmware revisions extended Modbus RTU, PROFIBUS DP, and Ethernet/IP compatibility without hardware replacement — a key factor in the platform's longevity in brownfield sites.

As of 2026, the MasterLogic series is in a mature/end-of-active-development lifecycle phase. Honeywell has transitioned new project specifications toward the Experion PKS C300 controller and Safety Manager SC platforms. However, the installed base of MasterLogic systems in operating plants remains substantial, and the demand for spare modules — particularly CPU, communications, and power supply variants — continues across the maintenance and lifecycle-extension market segment.

MasterLogic Full Catalog & Functionalities (SKU List)

The following SKUs represent verified, commonly sourced modules within the Honeywell MasterLogic platform. Modules are categorized by functional role within the control architecture.

CPU & Controller Modules

  • 2MLL-CPU1A: Standard single-CPU processor module, 1MB user memory, 10ms scan cycle
  • 2MLL-CPU2A: Enhanced CPU with 4MB memory, supports redundant CPU pairing
  • 2MLL-CPU2B: Redundant-capable CPU module with extended diagnostics and hot-standby switchover
  • 2MLL-CPU3A: High-performance CPU, 8MB memory, sub-5ms deterministic scan, Ethernet port onboard

Communications & Network Adapter Modules

  • 2MLL-CH2B-CC: Chassis communications controller; manages backplane arbitration and external network gateway interface
  • 2MLL-NET-MB: Modbus RTU/ASCII master/slave communications adapter, RS-485 isolated port
  • 2MLL-NET-PB: PROFIBUS DP master adapter, supports up to 125 slave nodes at 12Mbps
  • 2MLL-NET-EI: Ethernet/IP adapter module, 10/100 Base-T, CIP protocol stack
  • 2MLL-NET-DN: DeviceNet scanner module, supports up to 64 nodes

Digital Input/Output Modules

  • 2MLL-DI16A: 16-channel 24VDC digital input module, sink/source configurable, 3ms filter
  • 2MLL-DI32A: 32-channel 24VDC digital input, high-density, isolated commons per 8-channel group
  • 2MLL-DO16A: 16-channel 24VDC digital output, 0.5A per channel, short-circuit protected
  • 2MLL-DO16R: 16-channel relay output module, Form-C contacts, 2A/channel at 250VAC

Analog Input/Output Modules

  • 2MLL-AI8A: 8-channel analog input, 4–20mA / 0–10V selectable, 12-bit resolution
  • 2MLL-AI8B: 8-channel analog input, 16-bit resolution, HART pass-through on all channels
  • 2MLL-AO4A: 4-channel analog output, 4–20mA, 12-bit, loop-powered with diagnostics
  • 2MLL-AO8A: 8-channel analog output, 16-bit, HART-enabled, open-loop detection

Power Supply Modules

  • 2MLL-PS24A: 24VDC chassis power supply, 10A output, wide-range AC input (85–264VAC)
  • 2MLL-PS24R: Redundant power supply module, hot-swap capable, load-sharing with 2MLL-PS24A

Sourcing Hard-to-Find & Obsolete MasterLogic Parts

DriveKNMS supports installed-base sourcing for this series through RFQ review, including model matching, condition checks and documentation requirements before quotation.

All sourced modules are accompanied by full traceability documentation and are subject to DriveKNMS incoming inspection protocols before dispatch.

Quality Control for the MasterLogic Range

MasterLogic modules present specific test challenges due to their proprietary backplane bus protocol and multi-layer board construction. DriveKNMS applies the following test procedures to all MasterLogic units processed through its facility:

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top