Honeywell CC-PFB801 Modules: 51410087-175

Model: 51410087-175 CC-PFB801

Brand Honeywell
Series CC-PFB801
Model 51410087-175 CC-PFB801
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Honeywell CC-Series Technical Notes

The Evolution of CC-Series Architecture

The CC-Series was introduced as part of Honeywell's Experion PKS (Process Knowledge System) platform in the early 2000s, replacing the legacy TDC 3000 and PlantScape architectures. The initial C200 controller generation established the FTE (Fault Tolerant Ethernet) backplane standard. The C300 controller (CC-PCF901 / CC-PCF902) succeeded it with higher processing throughput and expanded I/O capacity per chassis. The CC-Series I/O modules — including analog input (CC-TAIX01), analog output (CC-TAOX01), digital input (CC-TDIL01), and digital output (CC-TDOL01) — were designed for hot-swap replacement without process interruption, a critical requirement in continuous-process industries.

CC-Series Full Catalog & Functionalities (SKU List)

Controllers

  • CC-PCF901: C300 Process Controller, standard redundancy, FTE backplane
  • CC-PCF902: C300 Process Controller, enhanced memory, dual FTE ports
  • CC-PCNT01: C300 Controller Node, single chassis configuration

Analog I/O Modules

  • CC-TAIX01: 8-channel 4–20 mA analog input, HART-enabled, isolated
  • CC-TAOX01: 8-channel 4–20 mA analog output, HART-enabled, isolated
  • CC-TAIM01: 8-channel analog input, millivolt/thermocouple range
  • CC-TAOM01: 8-channel analog output, millivolt range

Digital I/O Modules

  • CC-TDIL01: 24-channel 24 VDC digital input, isolated per group
  • CC-TDOL01: 24-channel 24 VDC digital output, solid-state, isolated
  • CC-TDIL11: 24-channel 120 VAC digital input, isolated
  • CC-TDOL11: 16-channel 120 VAC digital output, relay contact

Fieldbus & Communication Modules

  • CC-PFB801 (51410087-175): FOUNDATION Fieldbus H1 Interface, 2-segment, 16 devices/segment, integrated power conditioner
  • CC-PFB801E: Enhanced FF H1 Interface, extended diagnostics, HART pass-through
  • CC-PAIH01: PROFIBUS DP Interface Module, master class 1, up to 125 slaves
  • CC-PDOB01: DeviceNet Interface Module, scanner function, 64-node capacity
  • CC-LINK01: Modbus TCP/RTU Gateway Module, serial and Ethernet dual-port

Power & Chassis

  • CC-PWR001: 24 VDC chassis power supply, 40 W, redundancy-capable
  • CC-PWR002: Redundant power supply module, hot-swap, status LED
  • CC-CBKT01: 8-slot I/O chassis, FTE backplane, DIN-rail or panel mount

Sourcing Hard-to-Find & Obsolete CC-Series Parts

DriveKNMS sources CC-Series modules through decommissioned plant buybacks, certified refurbishment programs, and verified surplus channels. All units are cross-referenced against Honeywell's published part number revision history to ensure compatibility with installed firmware and chassis revisions. For end-users operating Experion PKS R400 through R520 environments, DriveKNMS can confirm module compatibility prior to shipment.

Quality Control for the CC-Series Range

CC-Series modules incorporate a proprietary FTE backplane bus and IOTA (I/O Termination Assembly) interface that requires specialized test procedures beyond standard bench testing. DriveKNMS applies the following protocol to all CC-Series units:

  • Backplane connector inspection: pin alignment, oxidation, and mechanical integrity verification against Honeywell dimensional specifications
  • Functional power-on test: module boot sequence validation, LED status confirmation (RUN, FAULT, COMM indicators)
  • Communication bus test: FTE Ethernet port continuity and packet integrity check using protocol analyzer
  • For CC-PFB801 specifically: H1 segment termination resistance measurement (100 Ω ± 2%), power conditioner output voltage verification (9–32 VDC per IEC 61158-2), and segment load simulation with dummy device nodes
  • Firmware revision logging: each unit's embedded firmware version is recorded and disclosed to the buyer prior to shipment
  • Final burn-in: 48-hour powered soak test at ambient temperature with periodic status polling

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top