Honeywell CC-PAON01 Output Analog Module – Obsolete Experion PKS Spare Part

When a Honeywell CC-PAON01 analog output module fails in an active Experion PKS installation, the consequences extend far beyond a single loop going offline. The C300 Controller architecture depends on this module to translate digital control commands into 4–20 mA field signals that drive control valves, variable frequency drives, and positioners across the process unit. A single failed module can force a partial or full unit shutdown. In refineries, chemical plants, and power generation facilities where Experion PKS systems have been in continuous operation for 15–20 years, the cost of an unplanned outage — combined with the engineering expense of migrating to a current-generation DCS platform — routinely reaches seven figures. DriveKNMS maintains RFQ-reviewed sourcing status of the CC-PAON01 (part number 51410070-175) specifically to protect facilities from that scenario.

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Part Number CC-PAON01
Honeywell Reference 51410070-175
Module Type Process Analog Output Module (PAON)
Compatible Platform Honeywell Experion PKS – C300 Controller Series
Signal Type 4–20 mA analog output
Communication Bus FTE (Fault Tolerant Ethernet) / C300 backplane
Discontinuation Status Obsolete – No longer manufactured or supported by Honeywell
Country of Origin United States
Condition Available New surplus / Professionally refurbished

Solving the Discontinued Hardware Crisis

The Honeywell Experion PKS platform, built around the C300 Controller and its associated I/O modules, was deployed extensively in the process industries from the early 2000s onward. Many of these installations are now operating well past their original design lifecycle. Honeywell has progressively discontinued hardware support for first- and second-generation C300 I/O modules, including the CC-PAON01, leaving plant engineering teams with a narrow set of options: source replacement hardware on the secondary market, undertake a full DCS migration, or accept the operational risk of running without spares.

How to extend your Experion PKS system life by 5–10 years:

Condition & Reliability Assurance

Obsolete hardware sourced from the secondary market carries inherent risk. DriveKNMS applies a structured 5-step qualification process to every CC-PAON01 unit before it is offered for sale:

  1. Visual and mechanical inspection. Full examination of the module housing, PCB, edge connector pins, and label integrity. Units with physical damage, corrosion, or evidence of field repair are rejected.
  2. Electrolytic capacitor assessment. Aging electrolytic capacitors are the primary failure mode in I/O modules that have been in storage or light service for extended periods. Each unit is evaluated for capacitor condition; units showing ESR drift or physical swelling are disqualified.
  3. Firmware version verification. The firmware revision is read and documented. This information is provided to the buyer to confirm compatibility with their installed C300 revision before dispatch review.
  4. Pin and connector integrity check. All backplane connector pins are inspected for oxidation, bending, and contact resistance. Pins are cleaned where necessary; units with deformed or corroded pins are rejected.
  5. Functional power-on test. Where test equipment permits, units are powered and checked for basic initialization and communication response prior to packaging.

Key Features for System Maintenance

Q: How is condition confirmed before quotation?
A: Available condition, photos, test records and documentation are checked according to the requested model and sourcing channel before a formal RFQ response.

How do I know the unit is genuine Honeywell and not a counterfeit?
All units are inspected against known-good reference units for label authenticity, PCB markings, and component population. We do not source from unverified liquidation channels. Provenance documentation is available on request for units where traceability records exist.

Should I buy more than one unit?
For any CC-PAON01 application on a critical process loop, holding a minimum of one spare per unit is standard practice. Given that this part is obsolete and secondary market availability will decrease over time, facilities with multiple C300 installations should consider consolidating their spare procurement now while RFQ-reviewed sourcing status is available.