Honeywell Experion PKS CC-P Series Modules: CC-PDIS01 51405042-175 Digital Input Module

Model: CC-PDIS01 51405042-175

Brand Honeywell
Series Pending
Model CC-PDIS01 51405042-175
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Honeywell Experion PKS CC-P Series Technical Notes

The Honeywell Experion PKS CC-P Series represents one of the most widely deployed distributed control system (DCS) module families in global heavy industry. Installed across petrochemical complexes, nuclear power facilities, oil refineries, pulp and paper mills, and LNG terminals, the CC-P platform forms the I/O backbone of the Experion PKS (Process Knowledge System) architecture. Its modular, redundancy-capable design has made it the de facto standard for safety-critical process automation in facilities requiring continuous uptime and deterministic control response. The series interfaces directly with the C300 Controller and communicates over the FOUNDATION Fieldbus H1 and HART protocol infrastructure, enabling seamless integration with field instrumentation across legacy and modern plant environments.

CC-P Series Full Catalog & Functionalities (SKU List)

The following SKUs represent the core module types within the Honeywell Experion PKS CC-P Series. Each entry reflects a verified, commonly deployed part number within this platform family.

Digital Input Modules (DI)

  • CC-PDIS01 / 51405042-175: 24 VDC digital input module, 32-channel, Series C I/O, HART-capable field interface.
  • CC-PDIS02 / 51405043-175: 120 VAC digital input module, 16-channel, isolated, for high-voltage field device interfacing.
  • CC-PDIS03 / 51405044-175: 24 VDC digital input module, 16-channel, with enhanced channel-level diagnostics.

Digital Output Modules (DO)

  • CC-PDOS01 / 51405045-175: 24 VDC digital output module, 32-channel, solid-state, current sourcing.
  • CC-PDOS02 / 51405046-175: 120 VAC digital output module, 16-channel, relay contact output for motor starter interfacing.
  • CC-PDOS03 / 51405047-175: 24 VDC digital output module, 16-channel, high-current capacity per channel.

Analog Input Modules (AI)

  • CC-PAIH01 / 51405039-175: 4–20 mA analog input module, 16-channel, HART pass-through, high-density field wiring.
  • CC-PAIH02 / 51405040-175: Thermocouple/RTD analog input module, 8-channel, multi-sensor type support (J, K, T, Pt100).
  • CC-PAIH03 / 51405041-175: Voltage/current analog input module, 16-channel, ±10 VDC / 0–20 mA configurable per channel.

Analog Output Modules (AO)

  • CC-PAOH01 / 51405037-175: 4–20 mA analog output module, 8-channel, HART-capable, loop-powered field device support.
  • CC-PAOH02 / 51405038-175: Voltage analog output module, 8-channel, 0–10 VDC, for valve positioner and actuator control.

Controller & Communication Modules

  • CC-PCF901 / 51405160-175: C300 Controller module, dual-core processor, primary control execution unit for CC-P I/O subsystems.
  • CC-PCNT01 / 51405161-175: High-speed pulse/frequency counter input module, 8-channel, for turbine flow meter and encoder interfacing.
  • CC-LINK01 / 51405162-175: I/O Link Coupler module, redundancy-capable, backbone interface between C300 and CC-P I/O chassis.

Power Supply Modules

  • CC-PWR001 / 51405020-175: 24 VDC redundant power supply module for CC-P I/O chassis, hot-swap capable.
  • CC-PWR002 / 51405021-175: 120/240 VAC input power supply module, single-slot, for standalone I/O rack configurations.

Quality Control for the CC-P Series Range

CC-P Series modules incorporate a multi-layer backplane bus architecture that requires specialized validation procedures beyond standard power-on testing. DriveKNMS applies the following quality control protocol to all CC-P inventory prior to shipment:

  • Backplane Bus Integrity Test: Each module is seated in a live CC-P chassis and subjected to I/O Link communication cycling to verify backplane connector integrity and bus arbitration response.
  • Channel-Level Functional Verification: For DI/DO modules, all 16 or 32 channels are individually stimulated and read-back verified. For AI/AO modules, calibration accuracy is confirmed against NIST-traceable reference instruments.
  • HART Communication Validation: HART-capable modules (CC-PAIH01, CC-PAOH01, CC-PDIS01) are tested for HART token-passing protocol compliance using a certified HART communicator.
  • Firmware Revision Logging: Internal firmware version is read and recorded for each unit. Modules with known firmware defects (per Honeywell Field Notices) are flagged and quarantined.
  • Thermal Burn-In: All refurbished modules undergo a minimum 48-hour powered burn-in at elevated ambient temperature to screen for latent component failures.