Honeywell 10014 Series Modules 10014/H/F Communication Module
Honeywell 10014/H/F is listed for Communication Modules RFQ review. Confirm quantity, condition and destination before quotation.
Model: DC-TPOX01 51307770-176
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
When a PROFIBUS interface board fails inside a Honeywell TDC3000 or legacy Experion PKS distributed control system, the consequences extend far beyond a single module replacement. A forced migration to a modern DCS platform — driven by one unavailable spare part — routinely carries engineering, commissioning, and production-loss costs measured in the millions of dollars. The DC-TPOX01 (P/N 51307770-176) is a confirmed discontinued component. DriveKNMS maintains RFQ-reviewed sourcing status of this board, sourced through controlled industrial channels, for facilities that cannot afford to treat a hardware failure as a system retirement event.
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
| Manufacturer | Honeywell Process Solutions |
| Part Number | DC-TPOX01 |
| Reference Number | 51307770-176 |
| Function | PROFIBUS PGM IOTA / PGM IOM Interface Board |
| Compatible Platform | Honeywell TDC3000, Experion PKS (legacy configurations) |
| Communication Protocol | PROFIBUS DP |
| Product Status | Discontinued / Obsolete – No longer manufactured by Honeywell |
| Country of Origin | United States |
Note: Electrical parameters beyond those listed above are not published here to prevent misapplication. Buyers are advised to cross-reference against their system documentation prior to installation.
The Honeywell TDC3000 platform has been the backbone of continuous process control in petrochemical, refining, pulp and paper, and power generation facilities for decades. Its architecture — built around the Universal Control Network (UCN) and the Local Control Network (LCN) — was engineered for long-cycle industrial operation, not for the rapid hardware refresh cycles of the IT world. The DC-TPOX01 PROFIBUS interface board sits at a critical junction in this architecture: it bridges field-level PROFIBUS DP devices to the PGM IOTA/IOM subsystem, enabling the control system to read and command instrumentation that would otherwise be invisible to the DCS.
Obsolete boards sourced from the secondary market carry inherent risks that do not exist with new production parts. DriveKNMS applies a structured 5-step qualification process to every DC-TPOX01 unit before it is offered for sale:
Step 1 – Electrolytic Capacitor Inspection: Boards of this generation use aluminum electrolytic capacitors with a finite service life. Each unit is inspected under magnification for signs of electrolyte leakage, case bulging, or venting. Capacitors showing any degradation are replaced with specification-matched components before the board is cleared.
Step 2 – Firmware Version Verification: The DC-TPOX01 carries embedded firmware that must match the revision level expected by the host TDC3000 system. Each board's firmware version is documented and disclosed to the buyer prior to shipment. Mismatched firmware is a known cause of intermittent communication faults that are difficult to diagnose in the field.
Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.
Step 4 – Functional Bench Test: Where test infrastructure permits, boards are powered and subjected to communication loop testing to confirm basic PROFIBUS DP master/slave handshake functionality.
Step 5 – Packaging and ESD Protection: Cleared units are packaged in anti-static bags with desiccant, labeled with the qualification date and technician ID, and stored in a controlled-humidity environment until shipment.
The DC-TPOX01 is a direct hardware replacement for the original board position in the TDC3000 PGM IOTA chassis. No firmware re-flashing of the host controller is required for a like-for-like swap. No re-engineering of the PROFIBUS segment configuration is necessary provided the replacement board carries a compatible firmware revision. The board slots into the existing backplane, restoring the PROFIBUS interface without any modification to the surrounding control architecture.
Q: Can this board be used in an Experion PKS system?
A: The DC-TPOX01 is designed for the TDC3000 PGM IOTA/IOM architecture. Compatibility with Experion PKS configurations depends on the specific hardware revision and system software version in use. Buyers should confirm compatibility against their system documentation before ordering.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.