Products / Honeywell / CCI-UNI-02 Communication Cable
Honeywell CCI-UNI-02 Communication Cable

Honeywell FS-CCI-UNI-02 Communication Cable – Obsolete Safety Manager Spare Part

Model: FS-CCI-UNI-02

Brand Honeywell
Series CCI-UNI-02 Communication Cable
Model FS-CCI-UNI-02
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Honeywell FS-CCI-UNI-02 Communication Cable – Obsolete Safety Manager Spare Part

When a communication cable fails inside a Honeywell Safety Manager installation, the consequences extend far beyond a single line stoppage. The FS-CCI-UNI-02 is a dedicated interface cable used within Honeywell's Safety Manager (SM) platform — a Safety Instrumented System (SIS) widely deployed across oil & gas, petrochemical, and power generation facilities since the early 2000s. Honeywell has discontinued this component as part of the broader Safety Manager product lifecycle transition toward the Safety Manager SC generation.

Replacing a Safety Manager installation is not a cable swap. It is a multi-year capital project. Engineering assessments, SIL re-validation, FAT/SAT testing, and process shutdowns routinely push total migration costs into the millions of dollars. A single unavailable cable — one that costs a fraction of a percent of that budget — can force a plant manager's hand toward a premature and unbudgeted system retirement. DriveKNMS maintains verified physical stock of the FS-CCI-UNI-02 specifically to prevent that outcome.

Technical Specifications

Parameter Detail
Part Number FS-CCI-UNI-02
Manufacturer Honeywell
Product Family Safety Manager (SM) Series
Component Type Communication / Interface Cable
Application Safety Instrumented System (SIS) internal communication
Compatible Platform Honeywell Safety Manager (pre-SC generation)
Lifecycle Status Discontinued / Obsolete
Country of Origin United States
Condition Available New Old Stock (NOS) / Tested Refurbished

Note: Electrical parameters such as conductor gauge, shielding specification, and connector pinout are not published independently of the Safety Manager system documentation. DriveKNMS does not fabricate specifications. Buyers requiring full cable drawings should reference Honeywell SM engineering documentation or contact our technical team.

Solving the Discontinued Hardware Crisis

The Honeywell Safety Manager platform was engineered for long service lives in high-consequence environments. Many installations commissioned between 2002 and 2012 remain in active SIL 2 and SIL 3 service today. The FS-CCI-UNI-02 cable forms part of the internal communication backbone of these systems — connecting controller modules and enabling the deterministic data exchange that underpins functional safety certification.

Honeywell's end-of-life notices for Safety Manager components have created a documented spare parts gap. Authorized distribution channels have exhausted stock. OEM repair programs have closed. The facilities that still operate these systems are left with three options: source parts from the secondary market, accept degraded redundancy, or fund a full system replacement.

For plant managers facing this decision, the arithmetic is straightforward. A verified FS-CCI-UNI-02 from a qualified secondary supplier extends the operational window of an existing, validated, SIL-certified installation. That extension — measured in years, not months — defers capital expenditure, preserves institutional knowledge embedded in the existing configuration, and avoids the production risk inherent in any major control system migration.

Facilities that have adopted a structured obsolete-parts inventory strategy for their Safety Manager installations report the ability to extend asset service life by 5 to 10 years beyond OEM support termination. The strategy requires three elements: a current-state audit of all cable and module part numbers in the installation, a risk-ranked procurement plan that prioritizes single-source components with no cross-compatible alternatives, and a qualified supplier relationship for ongoing sourcing. The FS-CCI-UNI-02 falls into the highest-priority tier of that audit for any Safety Manager site — it is a single-source, non-substitutable interface component with no published cross-reference to current Honeywell SM SC cabling.

Condition & Reliability Assurance

DriveKNMS applies a 5-step quality process to all obsolete communication components before shipment:

  • Step 1 – Visual and Physical Inspection: Connector bodies, locking mechanisms, and cable jacket are examined for mechanical damage, UV degradation, and storage-related deformation.
  • Step 2 – Connector Pin Inspection: All pins are inspected under magnification for corrosion, oxidation, and deformation. Corroded contacts are flagged and the unit is rejected from new-old-stock classification.
  • Step 3 – Continuity and Isolation Testing: Each conductor is tested for continuity end-to-end. Cross-conductor isolation is verified to confirm no internal short circuits resulting from insulation breakdown.
  • Step 4 – Electrolytic Component Check (where applicable): For cable assemblies incorporating active components or PCB termination boards, electrolytic capacitors are checked for ESR drift consistent with long-term storage aging.
  • Step 5 – Firmware / Label Verification: Part number markings, revision labels, and date codes are cross-referenced against known authentic Honeywell production records to confirm part identity before shipment.

Key Features for System Maintenance

  • Drop-in replacement: The FS-CCI-UNI-02 installs directly into existing Safety Manager cabinet positions. No re-engineering of cable routing or connector housings is required.
  • No reprogramming required: Communication cable replacement does not alter controller logic, SIL validation parameters, or system configuration. The Safety Manager resumes normal operation without a software intervention cycle.
  • Avoids engineering reconstruction costs: Sourcing this cable from secondary stock eliminates the need to engage a Honeywell system integrator for a hardware substitution study — a process that typically carries a five-figure engineering fee before any physical work begins.
  • Preserves SIL certification continuity: Replacing a like-for-like cable within a validated SIS installation is a maintenance activity, not a modification. It does not trigger mandatory SIL re-validation under IEC 61511, provided the replacement part meets the original specification.

FAQ

What warranty applies to an obsolete part like the FS-CCI-UNI-02?
DriveKNMS provides a 90-day functional warranty on all tested refurbished units and a 30-day warranty on new old stock. Warranty covers verified defects identified during installation. It does not cover damage resulting from incorrect installation or incompatible system configurations.

How do I confirm the unit is genuine and not a counterfeit?
Every unit shipped by DriveKNMS includes documentation of the inspection process completed prior to shipment. Part number markings and date codes are verified against Honeywell production records. We do not source from unverified liquidation channels. Buyers may request inspection photographs before purchase.

Should I buy more than one unit?
For any Safety Manager installation still in active service, holding a minimum of two FS-CCI-UNI-02 units as on-site spares is a defensible maintenance decision. Secondary market availability of this part is finite and declining. Once current stock is exhausted across the supplier network, sourcing lead times become unpredictable. A plant that experiences a cable failure without a spare on hand faces an unplanned shutdown of indeterminate length.

Can this cable be used with the Safety Manager SC?
The Safety Manager SC uses a revised hardware architecture. Compatibility with FS-CCI-UNI-02 has not been confirmed. Buyers should verify compatibility against their specific SM SC configuration before ordering.

© 2026 DriveKNMS. All trademarks belong to their respective owners. Specifications are for reference only and subject to change without notice. Verify all parameters against official documentation before installation.