Honeywell 10014 Series Modules 10014/H/F Communication Module
Honeywell 10014/H/F is listed for Communication Modules RFQ review. Confirm quantity, condition and destination before quotation.
Model: FS-CCI-UNI-02
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
When a communication cable fails inside a Honeywell Safety Manager installation, the consequences extend far beyond a single line stoppage. The FS-CCI-UNI-02 is a dedicated interface cable used within Honeywell's Safety Manager (SM) platform — a Safety Instrumented System (SIS) widely deployed across oil & gas, petrochemical, and power generation facilities since the early 2000s. Honeywell has discontinued this component as part of the broader Safety Manager product lifecycle transition toward the Safety Manager SC generation.
Replacing a Safety Manager installation is not a cable swap. It is a multi-year capital project. Engineering assessments, SIL re-validation, FAT/SAT testing, and process shutdowns routinely push total migration costs into the millions of dollars. A single unavailable cable — one that costs a fraction of a percent of that budget — can force a plant manager's hand toward a premature and unbudgeted system retirement. DriveKNMS maintains RFQ-reviewed sourcing status of the FS-CCI-UNI-02 specifically to prevent that outcome.
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
Note: Electrical parameters such as conductor gauge, shielding specification, and connector pinout are not published independently of the Safety Manager system documentation. DriveKNMS does not fabricate specifications. Buyers requiring full cable drawings should reference Honeywell SM engineering documentation or contact our technical team.
The Honeywell Safety Manager platform was engineered for long service lives in high-consequence environments. Many installations commissioned between 2002 and 2012 remain in active SIL 2 and SIL 3 service today. The FS-CCI-UNI-02 cable forms part of the internal communication backbone of these systems — connecting controller modules and enabling the deterministic data exchange that underpins functional safety certification.
For plant managers facing this decision, the arithmetic is straightforward. A verified FS-CCI-UNI-02 from a qualified secondary supplier extends the operational window of an existing, validated, SIL-certified installation. That extension — measured in years, not months — defers capital expenditure, preserves institutional knowledge embedded in the existing configuration, and avoids the production risk inherent in any major control system migration.
Facilities that have adopted a structured obsolete-parts inventory strategy for their Safety Manager installations report the ability to extend asset service life by 5 to 10 years beyond OEM support termination. The strategy requires three elements: a current-state audit of all cable and module part numbers in the installation, a risk-ranked procurement plan that prioritizes single-source components with no cross-compatible alternatives, and a qualified supplier relationship for ongoing sourcing. The FS-CCI-UNI-02 falls into the highest-priority tier of that audit for any Safety Manager site — it is a single-source, non-substitutable interface component with no published cross-reference to current Honeywell SM SC cabling.
DriveKNMS applies a 5-step quality process to all obsolete communication components before dispatch review:
How do I confirm the unit is genuine and not a counterfeit?
Every unit shipped by DriveKNMS includes documentation of the inspection process completed prior to shipment. Part number markings and date codes are verified against Honeywell production records. We do not source from unverified liquidation channels. Buyers may request inspection photographs before purchase.
Can this cable be used with the Safety Manager SC?
The Safety Manager SC uses a revised hardware architecture. Compatibility with FS-CCI-UNI-02 has not been confirmed. Buyers should verify compatibility against their specific SM SC configuration before ordering.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.