Pepperl+Fuchs NJ Series Inductive Sensors NJ1,5-8GM-N

Model: NJ1,5-8GM-N

Model NJ1,5-8GM-N
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Pepperl+Fuchs NJ Series Inductive Sensors Technical Notes

The Evolution of NJ Series Architecture

The NJ Series was introduced by Pepperl+Fuchs in the early 1980s as a standardized inductive sensor line designed to replace relay-based limit switches in machine tool and conveyor applications. The original NJ family used analog-output proximity circuits with discrete wiring; subsequent generations introduced IO-Link compatibility on select variants, enabling parameterization and diagnostic feedback over a single 3-wire cable without additional hardware.

Key architectural milestones include the transition from PVC-jacketed cable terminations to M12 quick-disconnect connectors (mid-1990s), the introduction of stainless-steel V2A and V4A housing options for food-grade and corrosive environments, and the addition of NAMUR-output variants (NJ…-N suffix) for use in intrinsically safe circuits in Zone 1/Zone 2 hazardous areas. The NAMUR output standard (EN 60947-5-6) is specifically relevant to the NJ1,5-8GM-N, which is designed for direct connection to NAMUR-compatible safety barriers and isolators in Ex-rated installations.

As the NJ Series has matured, many early-generation part numbers have entered end-of-life status. Pepperl+Fuchs has issued replacement recommendations for several discontinued variants, but installed base requirements in legacy DCS and SIS architectures frequently demand exact form-fit-function replacements rather than functional equivalents.

NJ Series Full Catalog & Functionalities (SKU List)

The following SKUs represent verified, commonly stocked part numbers within the Pepperl+Fuchs NJ Series. Each entry includes the primary functional descriptor. SKUs are organized by housing diameter and output type.

M8 Housing (8 mm diameter):

  • NJ1,5-8GM-N: M8 flush inductive sensor, 1.5 mm range, NAMUR output, for Ex Zone 1/2 applications
  • NJ1,5-8GM-N-5M: M8 flush, 1.5 mm range, NAMUR output, 5 m PVC cable termination
  • NJ1,5-8GK-N: M8 flush, 1.5 mm range, NAMUR output, short-body variant
  • NJ1,5-8GM-E2: M8 flush, 1.5 mm range, DC 3-wire PNP NO output, standard industrial
  • NJ1,5-8GM-E2-V3: M8 flush, 1.5 mm range, DC 3-wire PNP NO, V3 connector version

M12 Housing (12 mm diameter):

  • NJ2-12GM-N: M12 flush, 2 mm range, NAMUR output, Ex-rated proximity sensor
  • NJ4-12GM-N: M12 non-flush, 4 mm range, NAMUR output, extended sensing distance
  • NJ4-12GM-E2: M12 non-flush, 4 mm range, DC 3-wire PNP NO, general purpose
  • NJ4-12GK-N: M12 non-flush, 4 mm range, NAMUR output, short-body design
  • NJ2-12GM40-E2-V1: M12 flush, 2 mm range, PNP NO, 40 mm extended body, M12 connector

M18 Housing (18 mm diameter):

  • NJ5-18GM-N: M18 flush, 5 mm range, NAMUR output, standard hazardous area sensor
  • NJ8-18GM-N: M18 non-flush, 8 mm range, NAMUR output, extended range Ex sensor
  • NJ8-18GM-E2: M18 non-flush, 8 mm range, DC 3-wire PNP NO, general industrial
  • NJ5-18GK-N: M18 flush, 5 mm range, NAMUR output, short-body variant

M30 Housing (30 mm diameter):

  • NJ15-30GM-N: M30 non-flush, 15 mm range, NAMUR output, heavy-duty Ex proximity sensor
  • NJ15-30GM-E2: M30 non-flush, 15 mm range, DC 3-wire PNP NO, standard industrial
  • NJ10-30GM-N: M30 flush, 10 mm range, NAMUR output, flush-mount Ex sensor

Quality Control for the NJ Series Range

All NJ Series sensors processed through DriveKNMS undergo a structured inspection and functional test protocol prior to shipment:

  • Visual inspection: Housing thread condition, cable jacket integrity, connector pin condition, and label legibility are checked against OEM specifications.
  • Electrical continuity: Supply voltage, output switching state, and leakage current are measured at rated operating voltage (for NAMUR variants: 8 VDC per EN 60947-5-6).
  • Switching distance verification: Sensing range is confirmed using a standard Fe360 target at rated operating distance and hysteresis boundaries.
  • NAMUR threshold test: For -N suffix variants, open-circuit and short-circuit current levels are verified to confirm compatibility with downstream safety barriers (e.g., Pepperl+Fuchs Z728, MTL7706).
  • Temperature cycling: Spot-checked units are subjected to thermal cycling per IEC 60068-2-14 to verify seal integrity and output stability.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top