Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Pro-face PL6700-T11-W901F Touch Screen – Obsolete GP-Pro EX Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Attribute Detail
Manufacturer Pro-face (Schneider Electric)
Part Number PL6700-T11-W901F
Product Series PL6700 Series
Device Type Industrial HMI / Operator Touch Panel
Country of Origin Japan
Lifecycle Status Discontinued / Obsolete
Compatible Software GP-Pro EX
Typical System Integration Legacy Pro-face GP-Pro EX control architectures; commonly paired with Mitsubishi MELSEC, Omron CJ/CS series, and Siemens S7 PLCs via serial or Ethernet communication

Note: Electrical parameters such as supply voltage, display resolution, and communication port specifications are not published here to avoid inaccuracy. Please contact us directly for the full datasheet.

Solving the Discontinued Hardware Crisis

The PL6700-T11-W901F is no longer manufactured. Pro-face (now under Schneider Electric) has formally ended production and support for this model. For plant engineers, this creates a specific and serious problem: the HMI is not a standalone device. It is deeply integrated into the control logic, communication topology, and operator workflow of the surrounding system. Replacing it with a current-generation panel requires software migration, driver re-mapping, and in many cases, a complete re-validation of the control system — a process that can take months and carries significant risk of introducing new faults into a previously stable process.

The operational reality is that many facilities running this hardware are in industries where system certification, regulatory compliance, or simply the cost of re-engineering makes migration economically irrational in the near term. Pharmaceutical batch processing, water treatment SCADA, automotive body shop lines, and food packaging systems built around this generation of Pro-face hardware are still running production today. Keeping a verified spare PL6700-T11-W901F on the shelf is not a workaround — it is a deliberate asset protection strategy. It converts a potential multi-week production crisis into a same-shift swap.

Condition and Reliability Assurance

Every PL6700-T11-W901F unit that leaves DriveKNMS goes through a structured 5-step inspection protocol before dispatch review. This process is designed specifically for the failure modes common to HMI panels that have been in storage or removed from service.

Step 1 – Electrolytic Capacitor Assessment: Aging electrolytic capacitors are the primary cause of HMI failure in units of this generation. Each board is inspected for capacitor bulging, leakage, and ESR degradation. Units with compromised capacitors are either reconditioned or rejected.

Step 2 – Firmware Version Verification: The installed firmware version is confirmed and documented. Where applicable, compatibility with the customer's GP-Pro EX project version is verified before dispatch review.

Step 3 – Pin and Connector Corrosion Inspection: All I/O connectors, communication ports, and backplane contacts are inspected under magnification for oxidation, corrosion, and mechanical damage. Affected contacts are cleaned or the unit is rejected.

Step 4 – Touch Panel Calibration and Function Test: The touch screen digitizer is tested for dead zones, drift, and response accuracy across the full active area.

Step 5 – Power-On Functional Verification: The unit is powered and verified to complete its boot sequence, display correctly, and respond to input before packaging.

Key Features for System Maintenance

The PL6700-T11-W901F is a direct hardware replacement for the same part number in any existing installation. There is no requirement to modify PLC programs, rewrite GP-Pro EX project files, or reconfigure communication parameters — provided the replacement unit carries the same firmware baseline. This drop-in compatibility is the defining advantage over a cross-model substitution or a platform migration.

For maintenance teams operating under tight turnaround windows, this means the repair procedure is a physical swap and a communication parameter check — not an engineering project. There are no new software licenses to procure, no integrator to engage, and no re-validation cycle to schedule. The line returns to production on the same shift the replacement is installed.

How do I know the unit is genuine and not counterfeit?
DriveKNMS sources hardware through documented supply chains. Each unit is inspected for manufacturer markings, board construction, and component authenticity. We do not sell units that fail authenticity checks.

Can you confirm the unit will work with my specific GP-Pro EX project version?
Provide your GP-Pro EX project version and current firmware version at the time of inquiry. We will confirm compatibility before invoicing.