Schneider BMXART0814 Analog Input Module – Obsolete Modicon M340 Spare Part

Model: BMXART0814

Series Modicon M340
Model BMXART0814
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Schneider BMXART0814 Analog Input Module – Obsolete Modicon M340 Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Part Number BMXART0814
Manufacturer Schneider Electric
Series Modicon M340
Module Type Analog Input Module
Number of Channels 8 analog inputs
Input Signal Types Thermocouple (TC) and RTD (Pt100, Pt1000, Ni100, Ni1000)
Resolution 16-bit
Bus Interface Modicon M340 backplane (X Bus)
Country of Origin France
Discontinuation Status Discontinued – no longer available through standard Schneider Electric distribution
Compatible Systems Modicon M340 (BMX series), Unity Pro / EcoStruxure Control Expert software

Solving the Discontinued Hardware Crisis

The Modicon M340 platform was deployed extensively across process industries, water treatment, building automation, and discrete manufacturing throughout the 2000s and 2010s. Many of these installations are mid-lifecycle — the mechanical infrastructure, field wiring, and process logic represent decades of engineering investment that cannot be written off without significant capital expenditure.

Plants that have extended M340 system life through disciplined spare parts management consistently report total maintenance costs 60–80% lower than those that pursued reactive platform upgrades. The BMXART0814 is a low-cost insurance policy against a high-cost failure event.

Condition & Reliability Assurance

Sourcing discontinued industrial modules from secondary markets carries real risk. DriveKNMS applies a 5-step quality assurance process to every BMXART0814 unit before dispatch review:

  • Step 1 – Visual and Physical Inspection: Full examination of housing integrity, connector pins, and PCB surface. Units with corrosion, mechanical damage, or pin deformation are rejected.
  • Step 2 – Electrolytic Capacitor Assessment: Aging electrolytic capacitors are the primary failure mode in modules of this vintage. Each unit is assessed for capacitor condition; units showing signs of bulging, leakage, or ESR degradation are flagged.
  • Step 3 – Firmware Version Verification: The onboard firmware version is recorded and cross-referenced against known compatible versions for Unity Pro / EcoStruxure Control Expert. Incompatible or corrupted firmware versions are documented before dispatch review.
  • Step 4 – Pin and Connector Integrity Check: Backplane connector pins are inspected under magnification for oxidation, bending, and contact resistance issues that would cause intermittent faults in service.
  • Step 5 – Functional Power-On Test: Where test bench infrastructure permits, units are powered on and basic communication with the backplane is verified prior to packaging.

Each unit ships with a condition report. We do not misrepresent refurbished units as new-in-box unless the original sealed packaging is intact and verifiable.

Key Features for System Maintenance

  • Drop-in replacement: The BMXART0814 installs directly into any open M340 rack slot. No rack modification, no additional wiring adapters.
  • No reprogramming required: Unity Pro / EcoStruxure Control Expert recognizes the module by its hardware address. Existing I/O mapping and PLC program logic remain intact after module swap.
  • Avoids engineering rework costs: A direct replacement eliminates the need for control system engineers, system integrators, or Schneider service contracts to perform a migration project.
  • Preserves validated process logic: In regulated industries (pharmaceutical, food & beverage, water treatment), replacing a like-for-like module avoids triggering a full revalidation cycle — a significant compliance and cost advantage.
  • Extends asset life by 5–10 years: A functioning spare parts strategy for critical M340 modules allows plants to defer platform migration until it is planned, budgeted, and executed on their own schedule — not forced by an emergency failure.

Q: How do I know the unit is genuine and not counterfeit?
A: All units are sourced from decommissioned OEM installations or authorized secondary market channels. We provide traceability documentation where available. Units are inspected against known genuine hardware references. We do not source from unverified brokers.

Q: Should I buy more than one unit?
A: For any M340 installation with more than one BMXART0814 in service, holding at least one cold spare is standard practice. Given that this part is no longer manufactured, availability in the secondary market will decrease over time and prices will increase. Procurement teams managing long-term asset protection plans typically secure 2–3 units per critical module type.

Q: Can you supply other Modicon M340 modules?
A: Yes. DriveKNMS maintains inventory across the BMX series. Contact us with your full bill of materials for a consolidated quotation.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top