Siemens 6AV6671-5AE00-0AX0 HMI Mobile Panel – Obsolete SIMATIC Spare Part

Model: 6AV6671-5AE00-0AX0

Brand Siemens
Model 6AV6671-5AE00-0AX0
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens 6AV6671-5AE00-0AX0 HMI Mobile Panel – Obsolete SIMATIC Spare Part

DriveKNMS reviews sourcing status and documentation for this model during RFQ handling before quotation.

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Part Number 6AV6671-5AE00-0AX0
Brand Siemens
Series SIMATIC Mobile Panel 170
Product Type Portable HMI Mobile Panel
Display 5.7" STN color display
Resolution 320 × 240 px (QVGA)
Communication Interface MPI / PROFIBUS DP
Operating Voltage 24 V DC (supplied via cable)
Safety Function Integrated enabling device (3-position) + Emergency Stop
Protection Rating IP65 (front panel)
Country of Origin Germany
Discontinuation Status Officially discontinued by Siemens. No longer available through standard distribution channels.
Compatible Systems SIMATIC S7-300, S7-400, WinCC flexible 2008 and earlier

Solving the Discontinued Hardware Crisis

The 6AV6671-5AE00-0AX0 was designed for direct integration into SIMATIC S7-300 and S7-400 control architectures — systems that remain operational in thousands of manufacturing facilities across automotive, chemical, food processing, and heavy industry sectors. The panel's MPI/PROFIBUS DP interface, combined with its integrated three-position enabling device and hardwired emergency stop, made it a standard component in machine-level safety circuits.

Siemens has discontinued this model and its direct successors have shifted to PROFINET-based communication. Retrofitting a PROFINET-capable panel into an existing MPI/PROFIBUS machine requires hardware adapters, updated firmware on the PLC side, and re-validation of safety functions — a process that typically takes 3 to 6 weeks of engineering time per machine. For a facility with 20 or 30 such machines, the cumulative cost of forced migration is substantial.

Condition & Reliability Assurance

Discontinued HMI panels present specific failure risks that differ from standard wear items. Our 5-step QA process is designed around the known degradation patterns of this product family:

  • Step 1 – Electrolytic Capacitor Inspection: Capacitors on the power supply board are tested for ESR and capacitance drift. Units showing degradation beyond 20% of rated value are flagged for component-level repair before dispatch.
  • Step 2 – Firmware Version Verification: The installed firmware version is documented and cross-referenced against known compatibility matrices for S7-300/400 systems. Mismatched firmware is a common source of communication faults on legacy networks.
  • Step 3 – Pin and Connector Corrosion Check: All interface connectors — MPI port, power input, and enabling device socket — are inspected under magnification for oxidation and mechanical damage. Corroded contacts are cleaned or the connector assembly is replaced.
  • Step 4 – Display and Touchscreen Functional Test: The display is powered and tested for dead pixels, backlight uniformity, and touch response across the full active area.
  • Step 5 – Safety Circuit Continuity Test: The enabling device and emergency stop circuit are tested for correct switching behavior across all three positions of the enabling switch.

Key Features for System Maintenance

  • Drop-in Replacement: The 6AV6671-5AE00-0AX0 installs directly into existing cable infrastructure. No wiring modifications, no PLC program changes, no re-commissioning of safety functions.
  • No Reprogramming Required: HMI project files created in ProTool or WinCC flexible are fully compatible. The replacement unit loads the existing project without modification.
  • Avoids Engineering Reconstruction Costs: Substituting a non-identical panel triggers a change management process under most quality systems (ISO 9001, IATF 16949). Using an identical replacement unit keeps the machine's technical documentation valid and avoids a formal re-qualification cycle.
  • Extends Asset Life Without Capital Expenditure: Maintaining the existing control architecture with verified spare parts is consistently the lowest-cost option for facilities not yet scheduled for full automation renewal.

Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.

Q: Can you support multi-unit or repeat RFQ requests?
A: Yes. Send the model list, target quantity and destination so DRIVEKNMS can review sourcing options and quote the requirement as a project RFQ.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top