Siemens 6ES7414-3EM06-0AB0 CPU Module – Obsolete SIMATIC S7-400 Spare Part
Siemens SIEMENS 6ES7414-3EM06-0AB0 Central Processing Unit is listed for S7-400 RFQ review. Confirm quantity, condition and destination before quotation.
Model: 6ES7412-1XJ07-0AB0
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
| Parameter | Detail |
|---|---|
| Manufacturer | Siemens |
| Part Number | 6ES7412-1XJ07-0AB0 |
| Product Family | SIMATIC S7-400 |
| Module Type | Central Processing Unit (CPU) |
| Discontinuation Status | Discontinued / End of Life (EOL) – No longer manufactured |
| Compatible Rack | SIMATIC S7-400 UR1, UR2 series racks |
| Country of Origin | Germany |
| Condition Available | New surplus / Professionally refurbished |
Note: Electrical parameters not independently verified by DriveKNMS. Refer to the official Siemens SIMATIC S7-400 system manual for full specifications. We do not publish unverified data.
The SIMATIC S7-400 platform was Siemens' flagship high-performance PLC for large-scale process automation throughout the 1990s and 2000s. It became deeply embedded in industries where system stability is non-negotiable: oil and gas, pharmaceuticals, steel production, and automotive assembly. The 6ES7412-1XJ07-0AB0 CPU sits at the core of these installations — it is not a peripheral accessory that can be swapped with a generic substitute.
Siemens' official migration path points toward the S7-1500 series. That migration is not a parts swap. It requires complete hardware replacement, STEP 7 to TIA Portal project conversion, I/O remapping, safety validation, and in many cases, months of parallel operation testing. For a facility running 24/7 production schedules, this is not a decision made in a quarter. It is a multi-year capital project.
DriveKNMS specializes in locating, verifying, and supplying exactly these components. Our inventory is not sourced from liquidation lots without traceability. Each unit undergoes documented inspection before it is offered for sale.
Discontinued components carry risks that new-production parts do not. Electrolytic capacitor degradation, firmware version mismatches, pin corrosion from improper storage, and counterfeit units entering the secondary market are all documented failure modes. DriveKNMS applies a structured 5-step QA protocol to every obsolete CPU module before dispatch:
Step 1 – Physical Inspection: Full visual examination of the PCB, connector pins, housing, and label integrity. Units with signs of rework, burn marks, or pin damage are rejected.
Step 2 – Electrolytic Capacitor Assessment: Capacitor aging is the primary failure mechanism in stored PLC CPUs. We assess capacitor condition and flag units where degradation is evident.
Step 3 – Firmware Version Verification: The hardware revision and firmware version are documented and disclosed. Compatibility with your existing S7-400 rack configuration is confirmed prior to shipment where possible.
Step 4 – Pin and Contact Corrosion Check: Backplane connector pins are inspected under magnification. Oxidation is cleaned using approved contact restoration methods. Severely corroded units are not offered for sale.
The 6ES7412-1XJ07-0AB0 is a direct hardware replacement for the same part number within an existing S7-400 rack. There is no requirement to modify the existing STEP 7 program, reconfigure the hardware configuration file, or retrain operators. The replacement procedure follows standard Siemens hot-swap or cold-swap protocols depending on your system configuration.
Is the unit new or refurbished?
We disclose condition accurately at the time of quotation: new surplus (unused, original packaging where available) or professionally refurbished (tested, cleaned, documented). We do not misrepresent condition.
Should I buy more than one unit?
For any S7-400 installation where this CPU is the sole processing unit, holding a minimum of one verified spare is standard risk management practice. For multi-rack or redundant configurations, consult with your maintenance engineering team on appropriate buffer quantities. Global availability of this part number will continue to decline.
Can you source other S7-400 components?
Yes. DriveKNMS maintains sourcing capability across the SIMATIC S7-400 product range, including I/O modules, power supplies, interface modules, and communication processors. Contact us with your full BOM for a consolidated quotation.
Continue The Model Path