Siemens 6GK5108-0BA00-2AA3 Industrial Ethernet Switch – Obsolete SCALANCE X-100 Spare Part

Model: X108 6GK5108-0BA00-2AA3 MKS AS00296-02 0190-27709 C3575 , 715-011900-001

Brand Siemens
Model X108 6GK5108-0BA00-2AA3 MKS AS00296-02 0190-27709 C3575 , 715-011900-001
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens 6GK5108-0BA00-2AA3 Industrial Ethernet Switch – Obsolete SCALANCE X-100 Spare Part

DriveKNMS reviews sourcing options for this model through RFQ handling before quotation.

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Parameter Value
Manufacturer Siemens
Part Number 6GK5108-0BA00-2AA3
Product Family SCALANCE X-100 (X108)
Discontinuation Status Discontinued / Obsolete – No longer in Siemens active production
Number of Ports 8 x 10/100 Mbit/s RJ45
Network Protocol Industrial Ethernet / PROFINET compatible
Mounting DIN rail
Power Supply Input 24 V DC
Country of Origin Germany
Compatible Systems Siemens S7-300, S7-400, SIMATIC PCS 7, PROFINET-based architectures

Solving the Discontinued Hardware Crisis

The SCALANCE X108 (6GK5108-0BA00-2AA3) was a standard network component in Siemens-based automation cells built between the early 2000s and mid-2010s. It served as the backbone switch in PROFINET ring and line topologies, connecting PLCs, HMIs, drives, and I/O modules in a single Industrial Ethernet segment.

Facilities that have invested in Siemens SIMATIC PCS 7 distributed control systems, or that operate S7-400-based safety-instrumented systems, face a specific constraint: the network infrastructure was validated and documented as part of the original system qualification. Introducing a new switch model — even a functional equivalent — may trigger a revalidation requirement under internal change management protocols or regulatory frameworks such as FDA 21 CFR Part 11 or IEC 61511.

How to extend your automation asset life by 5 to 10 years using critical spare parts:

Plants that follow this approach routinely operate legacy Siemens automation systems 8 to 12 years beyond the original vendor end-of-life date, deferring capital expenditure on system replacement until it is operationally and financially justified — not forced by a single component failure.

Condition & Reliability Assurance

Every 6GK5108-0BA00-2AA3 unit processed by DriveKNMS passes a structured 5-step quality inspection before it is offered for sale. This protocol is designed specifically for discontinued industrial electronics, where age-related degradation is the primary failure risk.

  1. Electrolytic capacitor inspection. Capacitor aging is the leading cause of failure in legacy switching hardware. Each unit is inspected for bulging, leakage, and ESR deviation. Units with suspect capacitors are quarantined.
  2. Firmware version verification. The installed firmware is confirmed against the last known stable Siemens release for this product line. Units with corrupted or mismatched firmware are not offered for sale.
  3. Pin and connector corrosion check. All RJ45 ports and power terminals are inspected under magnification for oxidation, pin deformation, and contact resistance issues.
  4. Functional power-on test. Each unit is powered at rated voltage and all ports are tested for link establishment and traffic forwarding.
  5. Cosmetic and label verification. The Siemens product label, part number, and serial number are verified for authenticity. Counterfeit risk is a documented problem in the obsolete parts market. We do not source from unverified channels.

Key Features for System Maintenance

Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.

How do I know the unit is genuine and not counterfeit?
Every unit is inspected for label authenticity, part number consistency, and internal board markings. We source exclusively from decommissioned industrial facilities, authorized liquidators, and verified distributor overstock — not from anonymous online marketplaces. We do not sell units that fail our authentication check.

Q: Can you support multi-unit or repeat RFQ requests?
A: Yes. Send the model list, target quantity and destination so DRIVEKNMS can review sourcing options and quote the requirement as a project RFQ.

Can this unit be used with current Siemens hardware?
Yes. As an unmanaged Industrial Ethernet switch, the 6GK5108-0BA00-2AA3 is protocol-agnostic at the physical layer. It will operate alongside current Siemens SCALANCE, S7-1200, S7-1500, and ET 200 hardware without compatibility issues.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top