Siemens SINUMERIK 6FX2007 Modules 6FX2007-1AD13

Model: PHA-6FX2007-1AD13 6FX2007-1AD13

Brand Siemens
Model PHA-6FX2007-1AD13 6FX2007-1AD13
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens SINUMERIK 6FX2007 Series Technical Notes

The Evolution of SINUMERIK 6FX2007 Architecture

The 6FX2007 series was introduced as part of Siemens' broader SINUMERIK operator component ecosystem, succeeding earlier HHU designs tied to the SINUMERIK 840C and 810D platforms. Early-generation handheld units used proprietary serial interfaces with limited cable length options. The transition to PROFIBUS-based and later DRIVE-CLiQ-compatible architectures in the 840D sl era required corresponding updates to the HHU connector and cable specifications, reflected in distinct suffix variants within the 6FX2007 numbering scheme.

Key architectural transitions include: the shift from 25-pin to enabling device-integrated designs; introduction of IP65-rated enclosures for wash-down environments; integration of color displays in later MCP variants; and the standardization of straight vs. coiled cable configurations (denoted by suffix codes such as -1AD13 vs. -1AD14). Compatibility between 6FX2007 HHUs and specific NCU generations must be verified against Siemens compatibility matrices, as firmware dependencies exist between HHU hardware revisions and SINUMERIK software versions.

SINUMERIK 6FX2007 Full Catalog & Functionalities (SKU List)

The following SKUs represent the documented 6FX2007 product range. Each entry is classified by functional category and includes a concise technical descriptor.

Handheld Units (HHU) — Portable Operator Terminals

  • 6FX2007-1AD13: Mini Handheld Unit, straight cable, standard enabling device, SINUMERIK 840D sl compatible
  • 6FX2007-1AD14: Mini Handheld Unit, coiled cable variant, otherwise identical to -1AD13 specification
  • 6FX2007-1AD03: Handheld Unit without display, straight cable, basic jog and override functions
  • 6FX2007-1AD04: Handheld Unit without display, coiled cable, basic jog and override functions
  • 6FX2007-1AD23: Handheld Unit with 3-position enabling device, straight cable, enhanced safety rating
  • 6FX2007-1AD24: Handheld Unit with 3-position enabling device, coiled cable configuration
  • 6FX2007-1AD33: Handheld Unit with integrated display, straight cable, SINUMERIK 828D interface
  • 6FX2007-1AD34: Handheld Unit with integrated display, coiled cable, 828D interface

Machine Control Panels (MCP) — Fixed Panel Operator Interfaces

  • 6FX2007-1BF13: MCP 483C IE, Ethernet-based machine control panel, 483mm width, color display
  • 6FX2007-1BF03: MCP 483 IE, Ethernet interface, standard monochrome display, 483mm panel
  • 6FX2007-1BF23: MCP 310C IE, compact 310mm color display panel, Ethernet connectivity
  • 6FX2007-1BF33: MCP 310 IE, compact 310mm monochrome panel, Ethernet interface
  • 6FX2007-1BF43: MCP 483C USB, USB-interface variant of the 483mm color panel
  • 6FX2007-1BF53: MCP 310C USB, USB-interface compact color panel, 310mm form factor

Cables & Accessories — Interface and Connection Components

  • 6FX2007-1AC13: Connecting cable for HHU, straight, 5m length, standard HHU socket
  • 6FX2007-1AC14: Connecting cable for HHU, coiled, 5m extended length
  • 6FX2007-1AC23: Connecting cable for HHU, straight, 10m length for extended reach applications
  • 6FX2007-1AC33: HHU socket outlet for panel mounting, IP65 rated, flush installation

Quality Control for the SINUMERIK 6FX2007 Range

The 6FX2007 HHU and MCP product family presents specific quality verification requirements due to the safety-critical nature of enabling device circuits and the complexity of panel bus communication interfaces.

DriveKNMS applies the following test protocol to all 6FX2007 units processed through its facility:

  • Enabling Device Circuit Verification: 3-position enabling switch continuity and resistance testing across all switch positions, including the panic-release (fully depressed) state.
  • Cable Integrity Test: Full pin-to-pin continuity check on all cable conductors; insulation resistance test at 500V DC; visual inspection of connector housings and strain relief.
  • Display and Keypad Functional Test: All keys actuated and logged; display pixel uniformity verified; backlight intensity measured.
  • IP Rating Verification: Enclosure seal inspection; gasket condition assessment for units rated IP65.
  • MCP Bus Communication Test: Ethernet and USB interface units are connected to a SINUMERIK test bench and verified for correct enumeration and data exchange.
  • Firmware Revision Logging: Hardware revision codes are recorded and cross-referenced against known compatibility matrices for 840D sl and 828D NCU versions.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top