Yokogawa S9260 Modules S9260DE-01

Model: S9260DE-01

Brand Yokogawa
Series S9260
Model S9260DE-01
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Yokogawa S9260 Series Technical Notes

The Evolution of S9260 Architecture

The S9260 module family was introduced as the I/O expansion layer for Yokogawa's STARDOM FCN (Field Control Node) platform, which itself succeeded earlier standalone RTU architectures. The FCN controller, paired with S9260-series I/O modules, was positioned as a distributed, network-centric alternative to traditional rack-based DCS I/O subsystems.

Early S9260 deployments (circa 2004–2008) relied on a proprietary backplane bus connecting I/O modules to the FCN CPU base unit. Communication between the FCN and SCADA hosts used OPC-DA and Modbus TCP, with later firmware revisions adding OPC-UA support. The S9260 backplane supports hot-swap insertion on select module types, a feature critical for continuous-process facilities that cannot tolerate planned shutdowns for I/O maintenance.

S9260 Full Catalog & Functionalities (SKU List)

Digital Input / Output Modules

  • S9260DE-01: 16-ch digital input/output module, 24 VDC, dry contact compatible, FCN backplane bus
  • S9260DI-01: 16-ch dedicated digital input module, 24 VDC sink/source, status monitoring
  • S9260DO-01: 16-ch dedicated digital output module, 24 VDC, transistor output, 0.5 A per channel
  • S9260DI-02: 32-ch high-density digital input, 24 VDC, dual-row terminal block
  • S9260DO-02: 32-ch high-density digital output, 24 VDC, relay-isolated output option

Analog Input Modules

  • S9260AI-01: 8-ch analog input, 4–20 mA / 1–5 V, 16-bit resolution, HART pass-through
  • S9260AI-02: 16-ch analog input, 4–20 mA, multiplexed sampling, 500 ms scan cycle
  • S9260AI-03: 8-ch analog input, thermocouple / RTD universal, cold junction compensation
  • S9260AI-04: 4-ch high-speed analog input, 1 ms sampling, process surge detection

Analog Output Modules

  • S9260AO-01: 4-ch analog output, 4–20 mA, 12-bit resolution, loop-powered
  • S9260AO-02: 8-ch analog output, 4–20 mA, isolated per channel, HART capable

Communication & Interface Modules

  • S9260CM-01: RS-232C/RS-485 serial communication module, Modbus RTU master/slave
  • S9260CM-02: FOUNDATION Fieldbus H1 interface module, 2-segment, 32 device capacity
  • S9260CM-03: PROFIBUS DP master module, 12 Mbit/s, up to 125 slave nodes
  • S9260CM-04: DeviceNet scanner module, Group 2 only server support

Power Supply & Base Modules

  • S9260PS-01: 24 VDC backplane power supply module, 10 A output, redundancy-capable
  • S9260BU-01: 8-slot base unit for S9260 I/O modules, DIN rail mount, FCN bus connector

Quality Control for the S9260 Range

S9260 modules present specific test challenges due to their integrated backplane bus interface and mixed-signal I/O architecture. DriveKNMS applies the following test protocol to all S9260 units prior to dispatch:

  • Backplane Bus Integrity Test: Each module is seated in a live FCN base unit and polled via the internal bus to verify register read/write integrity and address resolution. Modules that fail to enumerate correctly are rejected.
  • Channel-Level I/O Verification: All analog channels are tested at 0%, 25%, 50%, 75%, and 100% of rated input/output range using calibrated signal sources. Digital channels are exercised through full ON/OFF cycle sequences with load simulation.
  • HART Communication Test (AI/AO modules): HART-capable modules are tested with a HART communicator to verify primary variable pass-through and device descriptor response.
  • Isolation Resistance Check: Channel-to-channel and channel-to-ground isolation is measured at 500 VDC. Minimum acceptable isolation: 10 MΩ.
  • Thermal Burn-In: Units are powered continuously for 48 hours at 40°C ambient prior to final inspection to screen for early-life component failures.
  • Firmware Version Logging: Firmware version is recorded and included in the shipment documentation. Customers requiring a specific firmware revision for compatibility with existing FCN CPU firmware are advised to specify this at time of order.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top