Products / Siemens / SQM10.16502
Siemens SQM10.16502

Siemens SQM10 Series Actuators — SQM10.16502

Model: SQM10.16502

Brand Siemens
Series SQM10.16502
Model SQM10.16502
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens SQM10 Series: Comprehensive Module Range and Technical Overview

The Siemens SQM10 series is a line of electromotoric rotary actuators engineered for precise positioning of rotary valves, dampers, and burner air/fuel ratio control systems in heavy industrial environments. Deployed across petrochemical refineries, thermal power stations, chemical processing plants, and district heating networks, the SQM10 range operates as a core component within Siemens LMV (Load Management and Valve) burner management systems. Its installed base spans decades of continuous operation in facilities where unplanned downtime carries significant financial and safety consequences. The series is characterized by its compact rotary design, integrated position feedback, and compatibility with Siemens LMV5x and LMV3x controller families, making it a standard reference in burner control engineering specifications globally.

The Evolution of SQM10 Architecture

The SQM10 series was introduced as part of Siemens' broader SKP/SQM actuator platform, designed to replace earlier electropneumatic and hydraulic positioning mechanisms with fully electric, self-contained rotary drives. Early variants in the SQM10 family provided basic open/close or modulating control with analog 0–10 V or 4–20 mA command interfaces. As burner management standards evolved — particularly with the adoption of EN 676 and EN 746 — the SQM10 series was updated to support direct integration with digital LMV controllers via the AZL2x display and parameter interface.

The architecture centers on a synchronous AC motor with integrated gear reduction, a potentiometer-based position feedback element, and auxiliary switch contacts for end-position signaling. Later production runs introduced improved EMC shielding and extended ambient temperature tolerance to meet installation requirements in outdoor boiler houses and marine applications. The SQM10 series does not use fieldbus communication (no PROFIBUS or PROFINET interface); it operates on hardwired analog and discrete signal interfaces, which defines its compatibility boundary with modern DCS architectures. Facilities migrating to fully digital control platforms must account for this interface gap when planning SQM10 replacements or retrofits.

SQM10 Full Catalog & Functionalities (SKU List)

The following SKUs represent the documented SQM10 series production range. Each unit is a rotary actuator variant differentiated by torque rating, running time, auxiliary switch configuration, and control signal type.

SQM10.16502: Rotary actuator, 1 Nm torque, 110 s/90°, 2-wire control, for LMV5x systems
SQM10.16500: Rotary actuator, 1 Nm torque, 110 s/90°, standard analog input, no auxiliary switch
SQM10.16501: Rotary actuator, 1 Nm torque, 110 s/90°, with single auxiliary switch contact
SQM10.16503: Rotary actuator, 1 Nm torque, 110 s/90°, dual auxiliary switch configuration
SQM10.16510: Rotary actuator, 1 Nm torque, 55 s/90°, fast-acting variant for rapid damper control
SQM10.16520: Rotary actuator, 1 Nm torque, 220 s/90°, slow-running variant for precise ratio control
SQM10.16530: Rotary actuator, 1 Nm torque, extended temperature range, outdoor-rated enclosure
SQM10.16540: Rotary actuator, 1 Nm torque, 110 s/90°, 0–10 V command signal, potentiometer feedback
SQM10.16550: Rotary actuator, 1 Nm torque, 4–20 mA command signal, current loop feedback
SQM10.16560: Rotary actuator, 1 Nm torque, spring-return safety function, fail-safe closed position
SQM10.16570: Rotary actuator, 1 Nm torque, spring-return, fail-safe open position variant
SQM10.16580: Rotary actuator, 1 Nm torque, manual override gear, for commissioning and maintenance
SQM10.16590: Rotary actuator, 1 Nm torque, stainless steel shaft, corrosion-resistant for chemical environments
SQM10.16600: Rotary actuator, 1.5 Nm torque, 110 s/90°, higher-torque variant for larger valve bodies
SQM10.16610: Rotary actuator, 1.5 Nm torque, dual auxiliary switch, LMV3x/LMV5x compatible
SQM10.16620: Rotary actuator, 1.5 Nm torque, spring-return, fail-safe, for critical fuel valve applications
SQM10.16700: Rotary actuator, 2.5 Nm torque, 110 s/90°, heavy-duty damper and butterfly valve control

Sourcing Hard-to-Find & Obsolete SQM10 Parts

The SQM10 series has entered the mature-to-declining phase of its product lifecycle. Siemens has progressively transitioned burner management system designs toward the SQM40, SQM45, and SQM48 actuator families, which offer higher torque ratings, integrated bus communication options, and improved diagnostic capabilities. As a result, several SQM10 variants are no longer available through standard Siemens distribution channels and are classified as discontinued or limited-availability parts.

DriveKNMS maintains a dedicated inventory of SQM10 series actuators sourced from decommissioned plant equipment, authorized surplus channels, and verified OEM stock. All units are cataloged by part number, production date code, and functional test status prior to listing. For facilities operating legacy LMV3x or LMV5x burner management systems where a direct controller upgrade is not feasible, DriveKNMS provides lifecycle extension support: sourcing specific SQM10 variants, cross-referencing discontinued part numbers to available equivalents, and advising on compatible replacement actuators where direct substitution is possible. Procurement teams managing long-term maintenance contracts for boiler houses, district heating plants, or industrial furnace systems are encouraged to submit consolidated parts lists for batch quotation.

Quality Control for the SQM10 Range

Each SQM10 unit processed by DriveKNMS undergoes a structured functional verification protocol before dispatch. The test sequence addresses the primary failure modes documented for this series: potentiometer wear causing erratic position feedback, auxiliary switch contact degradation, gear train backlash beyond specification, and motor winding resistance drift.

Verification steps include: input signal sweep test (0–10 V or 4–20 mA across full travel range), position feedback linearity check against factory tolerance bands, auxiliary switch actuation point verification at both end positions, mechanical rotation test for full 90° travel without binding or stall, insulation resistance measurement between motor windings and chassis, and visual inspection of shaft seal integrity and connector condition. Units exhibiting feedback nonlinearity exceeding ±2% of full scale or switch actuation deviation beyond ±1° of specified position are rejected and not offered for sale. Test records are retained and available upon request for quality-critical procurement processes.

WhatsApp Prefilled Inquiry Email [email protected] Phone +86 18359293191 Top Back To Top