GE IC695ETM001-CC Ethernet Interface Module – Obsolete PACSystems RX3i Spare Part
GE IC695ETM001-CC Ethernet Interface Module – Obsolete PACSystems RX3i Spare Part When a GE PACSystems RX3i Ethernet communication module fails,…
Model: IC695CPU310
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
A single IC695CPU310 failure does not merely halt one machine — it can shut down an entire production line built around the GE PACSystems RX3i platform. Replacing this controller today means migrating the entire control architecture: new hardware, new software licenses, re-engineering of ladder logic, re-commissioning, and operator retraining. Conservative estimates for a full RX3i system migration run from USD 300,000 to over USD 1,000,000 depending on plant complexity. Against that figure, securing a verified spare IC695CPU310 is not a procurement decision — it is a capital protection decision.
DriveKNMS maintains sourced inventory of the IC695CPU310 for facilities that cannot afford unplanned downtime or premature system retirement. Stock is limited and allocated on a first-confirmed basis.
| Parameter | Value |
|---|---|
| Part Number | IC695CPU310 |
| Series | GE PACSystems RX3i |
| Module Type | Central Processing Unit (CPU) |
| Backplane Compatibility | IC695 Universal Backplane (RX3i) |
| Communication Port | RS-232 Serial (front panel) |
| Ethernet | Not onboard – requires separate ETM module |
| Product Status | Discontinued / Obsolete |
| Successor Model | IC695CPE302 / IC695CPE330 (requires engineering migration) |
| Country of Origin | United States |
Note: Electrical parameters not listed above are not confirmed from verified documentation and are intentionally omitted. Accuracy of specifications is a safety matter for industrial installations.
The GE PACSystems RX3i platform was widely deployed across process industries — oil & gas, water treatment, automotive assembly, and food manufacturing — throughout the 2000s and 2010s. The IC695CPU310 served as the processing core of these systems, executing control logic, managing I/O communication across the RX3i backplane, and interfacing with SCADA and HMI layers via serial and third-party Ethernet modules.
GE Automation (now Emerson) has transitioned its PLC portfolio toward newer CPE-series processors. The IC695CPU310 is no longer manufactured. Facilities still operating RX3i systems face a structural problem: the control logic, field wiring, and operator interfaces were engineered around this specific hardware. A like-for-like CPU swap takes hours. A platform migration takes months — and carries significant risk of introducing new faults during commissioning.
For plant managers under pressure to defer capital expenditure, maintaining a verified spare IC695CPU310 on the shelf is the lowest-risk, lowest-cost continuity strategy available. One unit can extend the operational life of an RX3i-based line by 5 to 10 years, buying time for a planned, budgeted migration rather than a crisis-driven one.
Facilities running GE PACSystems RX3i systems — particularly those also using IC695PSD040 power supplies, IC694MDL754 output modules, or Proficy Machine Edition programming environments — should treat the IC695CPU310 as a critical single-point-of-failure component requiring dedicated spare coverage.
Sourcing obsolete industrial hardware from the secondary market carries real risk. DriveKNMS applies a structured 5-step inspection protocol before any IC695CPU310 unit is offered for sale:
Units that do not pass all five stages are not listed for sale. Condition (new, tested-surplus, or refurbished) is disclosed per unit at time of inquiry.
The IC695CPU310 is not the only component that determines the remaining service life of a PACSystems RX3i installation. Facilities seeking to extend system life by 5 to 10 years should conduct a structured spare parts audit covering the following risk tiers:
Tier 1 – Single points of failure (immediate spare required): CPU module (IC695CPU310), power supply module, and any communication gateway modules connecting the PLC to plant SCADA.
Tier 2 – High-cycle wear components (rolling spare stock): Digital and analog I/O modules with high switching frequency. Failure rates increase with age and cycle count.
Tier 3 – Planned obsolescence watch: Any module for which the secondary market supply is visibly thinning. Price increases and reduced availability are early indicators that a component is approaching end of secondary-market life.
A documented spare parts strategy, reviewed annually, converts reactive emergency procurement into a managed cost line. It also provides the data needed to make a rational, scheduled migration decision rather than one forced by an unplanned failure.
What warranty applies to an obsolete IC695CPU310?
DriveKNMS provides a limited warranty on all units sold. The specific warranty period and terms are confirmed at time of sale and depend on the unit's condition classification. Contact us for details before purchase.
How do I confirm the unit is genuine and not counterfeit?
All units are inspected against GE's original labeling and part number conventions. Firmware version and board markings are verified. We disclose the source classification (new old stock, tested surplus, or refurbished) for each unit. We do not sell units that cannot be verified.
Can I store a spare IC695CPU310 long-term?
Yes. CPU modules stored in a dry, temperature-stable environment (away from humidity and static) retain functionality for extended periods. We recommend anti-static packaging and annual visual inspection of stored units. For long-term storage exceeding three years, capacitor condition should be assessed before deployment.
Will this CPU work with my existing Proficy Machine Edition project?
The IC695CPU310 is compatible with Proficy Machine Edition. Your existing project file can be downloaded to the replacement unit. Confirm your firmware version requirements with your controls engineer before installation.
How quickly can you ship?
Lead time depends on current stock status. Contact us directly for availability confirmation and shipping timeline to your location.