Allen-Bradley 2711P-K15C4A8 PanelView Plus Terminal – Obsolete PanelView Plus 6 Spare Part

Model: 2711P-K15C4A8

Series PanelView
Model 2711P-K15C4A8
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley 2711P-K15C4A8 PanelView Plus Terminal – Obsolete PanelView Plus 6 Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Part Number 2711P-K15C4A8
Brand Allen-Bradley (Rockwell Automation)
Series PanelView Plus 6
Display Size 15 inch
Display Type Color TFT LCD, Keypad & Touch
Communication DH-485, RS-232, Ethernet/IP
Operating Voltage 24V DC
Country of Origin United States
OEM Status Discontinued – No longer manufactured or sold by Rockwell Automation
Compatible Platforms ControlLogix, CompactLogix, SLC 500, MicroLogix (via RSLinx / FactoryTalk)

Solving the Discontinued Hardware Crisis

The PanelView Plus 6 series was the dominant operator interface platform across North American and Asian manufacturing facilities throughout the 2000s and 2010s. The 2711P-K15C4A8 — the 15-inch keypad-and-touch variant — was deployed extensively in food and beverage, automotive assembly, water treatment, and pharmaceutical batch processing environments. Rockwell Automation has since transitioned its HMI portfolio to the PanelView 5000 series, which runs on a fundamentally different software stack (Studio 5000 Optix vs. FactoryTalk View ME). This is not a firmware update. Migrating from a PanelView Plus 6 application to PanelView 5000 requires a full application rewrite, new licensing, and in many cases, updated PLC logic to match revised tag structures.

Condition & Reliability Assurance

Discontinued hardware sourced outside the OEM channel carries inherent risk. DriveKNMS applies a structured 5-step qualification process to every 2711P-K15C4A8 unit before it is offered for sale:

Step 1 – Electrolytic Capacitor Inspection: Aging capacitors are the primary failure mechanism in HMI power supply boards. Each unit undergoes visual inspection and ESR measurement on all electrolytic capacitors in the power section. Units with bulging, leaking, or out-of-spec capacitors are either recapped with equivalent-rated components or removed from inventory.

Step 2 – Firmware Version Verification: The installed FactoryTalk View ME firmware version is documented and confirmed compatible with the customer's existing application version. Firmware mismatches between terminal and application can cause display errors or communication failures that are indistinguishable from hardware faults.

Step 3 – Pin and Connector Corrosion Audit: All I/O connectors, communication ports (RS-232, DH-485, Ethernet), and power terminals are inspected under magnification for oxidation, pin deformation, and contact resistance. Corroded connectors are cleaned or the unit is rejected.

Step 4 – Display and Touchscreen Functional Test: The LCD backlight, color uniformity, and touchscreen calibration are verified against factory specifications. Backlight hours are estimated where EEPROM data is accessible.

Step 5 – 48-Hour Burn-In: Each unit is powered continuously for 48 hours under simulated load conditions. Units that pass all five stages are classified as Qualified Refurbished and shipped with full documentation.

Key Features for System Maintenance

The 2711P-K15C4A8 is a direct hardware replacement for any existing PanelView Plus 6 15-inch keypad/touch unit installed in the same panel cutout. No mechanical modification is required. The unit accepts the existing FactoryTalk View ME application file without modification — there is no recompilation, no tag remapping, and no re-commissioning procedure beyond loading the application and verifying communication parameters. This is a drop-in replacement in the strictest engineering sense of the term.

For maintenance teams operating under ISA-18.2 alarm management standards or FDA 21 CFR Part 11 validation frameworks, the absence of any software change means the existing validation documentation remains intact. No change control record is required for the HMI application. The only documentation needed is a hardware replacement record — a standard corrective maintenance entry. This distinction alone can save weeks of revalidation work in regulated industries.

Q: How do I confirm the unit is new or qualified refurbished — not a counterfeit?
A: Every unit shipped by DriveKNMS includes a condition report documenting the 5-step QA process results, the firmware version installed, and the inspector's identification. We do not source from unverified brokers. Customers requiring additional traceability documentation should request it at the time of inquiry.

Q: Can this unit run a newer FactoryTalk View ME application version than what was originally installed?
A: FactoryTalk View ME applications are generally backward-compatible within the same major version family. Upgrading the terminal firmware to match a newer application version is possible in most cases. DriveKNMS can advise on firmware compatibility based on your specific application version — provide this information at the time of inquiry.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top