ABB TU849 Module Termination Unit – S800 I/O Series
ABB TU849 is listed for S800 I/O RFQ review. Confirm quantity, condition and destination before quotation.
Model: AI880A
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
| Parameter | Detail |
|---|---|
| Part Number | AI880A |
| Manufacturer | ABB |
| Series | S800 I/O |
| Compatible Controller | ABB AC 800M (PM860, PM861, PM864, PM866) |
| Channel Count | 8 Channels |
| Signal Type | Analog Input, High Integrity (HI), Single/Redundant (S/R) |
| Protocol Support | HART (Highway Addressable Remote Transducer) |
| Redundancy | Supports redundant configuration |
| Discontinuation Status | Discontinued / Obsolete – No longer in ABB active production |
| Country of Origin | Germany |
Note: Electrical parameters not independently verified are intentionally omitted. Specifications above are drawn from publicly available ABB S800 I/O documentation. Buyers requiring full datasheet confirmation should contact us directly.
The ABB S800 I/O platform was the backbone of process automation across refining, power generation, pulp and paper, and chemical manufacturing for over two decades. The AI880A, specifically, served high-integrity applications where HART communication and redundant signal paths were non-negotiable — transmitter diagnostics, valve positioner feedback, and safety-adjacent measurement loops.
ABB's transition toward the System 800xA and AC 800M successor architectures left a large installed base of S800 I/O hardware without a direct upgrade path that preserves existing wiring, marshalling cabinets, and control logic. A plant that standardized on the AI880A in the early 2000s cannot simply swap in a modern equivalent without re-engineering the I/O termination layer, revalidating HART device libraries, and re-testing every affected loop — a process that can consume 6 to 18 months of engineering effort per unit.
The practical consequence: facilities that maintain a strategic reserve of AI880A modules can defer that engineering burden indefinitely, or at minimum, execute it on their own schedule rather than under emergency conditions. The cost of one spare module is measured in thousands. The cost of an unplanned DCS migration is measured in millions.
Obsolete hardware sourced from secondary markets carries inherent risk. DriveKNMS applies a 5-step inspection protocol to every AI880A unit before it is offered for sale:
Units that do not pass all five stages are not offered for sale. Condition grade (New Surplus, Refurbished, or Tested Used) is disclosed on every order confirmation.
How do I know the unit is genuine and not counterfeit?
All units are sourced through traceable supply channels. Physical markings, label formats, and PCB characteristics are cross-referenced against known-genuine ABB S800 I/O hardware. Any unit where authenticity cannot be confirmed to our standard is not listed for sale.
Should we buy more than one unit?
For any facility with more than two AI880A modules in active service, holding at least one cold spare is a defensible maintenance decision. For facilities with redundant configurations, holding two spares — one per redundant pair — is the conservative position. The AI880A is no longer manufactured; secondary market availability will decrease over time, not increase.
Can you source other S800 I/O modules?
Yes. DriveKNMS specializes in obsolete and hard-to-find ABB S800 I/O, AC 800M, and related process automation hardware. Contact us with your full bill of materials for a consolidated sourcing assessment.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.