Yokogawa SDV500 Series Digital Valve Controllers SDV531-S13 S1
Yokogawa SDV531-S13 S1 is listed for SDV500 Series RFQ review. Confirm quantity, condition and destination before quotation.
Model: SDV531-S13
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
The Yokogawa SDV500 series of digital valve positioners occupies a critical position in global heavy industry infrastructure. Deployed across petrochemical complexes, nuclear power stations, LNG terminals, and crude oil refineries, the SDV500 platform provides precision electro-pneumatic valve control with HART and FOUNDATION Fieldbus communication capability. Its modular architecture and field-configurable parameters have made it a standard specification item in Yokogawa CENTUM VP and CENTUM CS 3000 distributed control system (DCS) environments. The series is engineered to IEC 60534-6 (NAMUR NE 107) standards and carries SIL 2 certification for safety-instrumented system (SIS) applications, making it a qualified component in IEC 61511-compliant process safety loops.
The following SKUs represent the verified SDV500 series product range, classified by mounting configuration, communication protocol, and action type:
SDV531-S13: Single-acting, HART, standard explosion-proof housing, 4–20 mA input
SDV531-S23: Single-acting, HART, stainless steel wetted parts, corrosion-resistant trim
SDV531-S33: Single-acting, HART, high-temperature service, –40 to +85°C ambient
SDV531-F13: Single-acting, FOUNDATION Fieldbus H1, standard explosion-proof housing
SDV531-F23: Single-acting, FOUNDATION Fieldbus H1, stainless steel wetted parts
SDV531-F33: Single-acting, FOUNDATION Fieldbus H1, high-temperature service variant
SDV532-S13: Double-acting, HART, standard explosion-proof housing, 4–20 mA input
SDV532-S23: Double-acting, HART, stainless steel wetted parts, corrosion-resistant trim
SDV532-S33: Double-acting, HART, high-temperature service, extended ambient range
SDV532-F13: Double-acting, FOUNDATION Fieldbus H1, standard explosion-proof housing
SDV532-F23: Double-acting, FOUNDATION Fieldbus H1, stainless steel wetted parts
SDV532-F33: Double-acting, FOUNDATION Fieldbus H1, high-temperature service variant
SDV541-S13: Single-acting, HART, quarter-turn rotary valve mounting, standard housing
SDV541-F13: Single-acting, FOUNDATION Fieldbus H1, quarter-turn rotary valve mounting
SDV542-S13: Double-acting, HART, quarter-turn rotary valve mounting, standard housing
SDV542-F13: Double-acting, FOUNDATION Fieldbus H1, quarter-turn rotary valve mounting
SDV531-S13/KF: SDV531-S13 with integrated solenoid valve for SIL 2 partial stroke testing
SDV531-F13/KF: SDV531-F13 with integrated solenoid valve for SIL 2 partial stroke testing
The SDV500 series presents specific test challenges due to its integrated pneumatic relay, digital positioner board, and HART/FF communication stack. DriveKNMS applies a structured multi-stage verification protocol to all SDV500 units prior to dispatch. Stage 1 covers visual and mechanical inspection: NAMUR mounting flange integrity, feedback shaft coupling condition, and pneumatic port thread condition (1/4 NPT or G1/4). Stage 2 covers electrical bench test: supply voltage range verification (3.6–20 mA loop current), HART communication handshake using a Fluke 710 or equivalent HART communicator, and zero/span auto-calibration cycle execution. Stage 3 covers pneumatic functional test: supply pressure regulation (1.4–7.0 bar), output pressure linearity across 0–100% travel, and hysteresis measurement per IEC 60534-6. Stage 4 covers diagnostic data extraction: valve signature baseline capture, friction and dead band measurement, and partial stroke test (PST) execution log. All test records are archived and supplied with the unit as a quality dossier.
Continue The Model Path