Products / Foxboro / I/A Series
Foxboro I/A Series

Foxboro P0926GH Pressure Transmitter – Obsolete I/A Series Spare Part

Model: P0926GH

Brand Foxboro
Series I/A Series
Model P0926GH
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Foxboro P0926GH Pressure Transmitter – Obsolete I/A Series Spare Part

When a Foxboro P0926GH pressure transmitter fails on a process line running an I/A Series distributed control system, the consequences extend far beyond a single instrument replacement. A full DCS migration — including engineering, commissioning, operator retraining, and production downtime — routinely costs between $500,000 and $3,000,000 USD per unit. The P0926GH is a discontinued component, and its absence from the open market forces many plant managers into that exact corner. DriveKNMS maintains verified stock of this part specifically to prevent that outcome.

Technical Specifications

Parameter Detail
Manufacturer Foxboro (Schneider Electric)
Part Number P0926GH
Product Series I/A Series
Product Category Pressure Transmitter / Sensor Module
Discontinuation Status Obsolete – No longer manufactured or supported by OEM
Country of Origin United States
Compatible Systems Foxboro I/A Series DCS (51 Series, 70 Series FBMs)
Condition Available New Old Stock (NOS) / Professionally Refurbished

Note: Electrical parameters such as input range, output signal, and supply voltage are model-configuration-dependent. Confirmed specifications are provided upon request with unit serial number verification. No parameters are assumed or fabricated.

Solving the Discontinued Hardware Crisis

The Foxboro I/A Series DCS platform was the backbone of process automation across refining, petrochemical, pulp and paper, and power generation facilities for over three decades. The P0926GH pressure transmitter served as a field measurement node within this architecture — feeding real-time process data to FBM (Field Bus Module) controllers that govern critical loop control.

Foxboro has formally discontinued this part. OEM replacement channels are closed. The engineering reality is that the I/A Series communication protocol and physical form factor are not directly compatible with current-generation transmitters without significant reconfiguration of the FBM, marshalling cabinets, and HART/fieldbus wiring infrastructure. A like-for-like drop-in replacement is the only path that avoids a cascade of downstream engineering changes.

For plant managers operating under capital expenditure constraints, the calculus is straightforward: a verified P0926GH spare part purchased today costs a fraction of one percent of the system migration it prevents. Facilities that have built a strategic buffer stock of critical obsolete instruments routinely extend DCS asset life by 5 to 10 years beyond OEM support end dates — without compromising process safety or regulatory compliance.

The strategy is not complicated. Identify the five to ten instruments on your I/A Series system with the longest lead times and no modern equivalents. Secure two to three units of each. Store them in controlled conditions. This single procurement decision has protected production continuity at facilities across the refining and chemical sectors for years after OEM support ended.

Condition & Reliability Assurance

Every P0926GH unit shipped by DriveKNMS passes a five-stage inspection protocol before it leaves our facility:

  • Electrolytic Capacitor Assessment: Aging electrolytic capacitors are the primary failure mode in legacy instrumentation. Each unit is inspected for capacitor bulge, leakage, and ESR deviation. Units with degraded capacitors are either recapped with equivalent-spec components or rejected.
  • Firmware Version Verification: Where applicable, firmware revision is confirmed against the known compatible version matrix for I/A Series FBM integration. Incompatible firmware revisions are flagged before shipment.
  • Terminal and Pin Corrosion Inspection: All electrical connection points are examined under magnification for oxidation, pitting, and mechanical deformation. Corroded contacts are treated or the unit is rejected.
  • Functional Bench Test: Units are powered and tested for signal output stability within specification tolerances.
  • Packaging for Long-Term Storage: Units are packaged in anti-static, moisture-barrier materials suitable for extended shelf storage if the part is being held as a strategic spare.

Key Features for System Maintenance

  • Drop-in Replacement: The P0926GH installs directly into the existing mounting position and wiring termination without modification to the field wiring or FBM configuration.
  • No Reprogramming Required: The replacement unit operates on the same signal protocol as the original. Control loop parameters, PID tuning, and historian tags remain intact.
  • No Engineering Rework: Avoiding a transmitter-type change eliminates the need for loop drawing revisions, management of change (MOC) procedures, and instrument index updates — each of which carries its own labor cost and production risk.
  • Immediate Availability: Stock is held in-house. Lead time is days, not months. For facilities running without a hot spare, this matters.

FAQ

What warranty applies to an obsolete part like the P0926GH?
DriveKNMS provides a 90-day functional warranty on all refurbished units and a 30-day warranty on New Old Stock units. Warranty covers failure under normal operating conditions and excludes damage from installation error or process overpressure.

How do I know the unit is genuine and not counterfeit?
All units are sourced through documented industrial decommissioning channels or authorized surplus distributors. Physical markings, date codes, and board construction are verified against known-authentic reference units. We do not source from unverified grey-market channels.

Should I buy more than one unit?
For any I/A Series system still in active production service, holding a minimum of two P0926GH spares is a defensible maintenance strategy. The part will not become easier to source over time. Each year that passes reduces available NOS inventory globally. Procurement now, at current pricing, is materially cheaper than emergency sourcing under production pressure.

Can you source other Foxboro I/A Series obsolete parts?
Yes. DriveKNMS specializes in hard-to-find and discontinued DCS components across Foxboro, Honeywell TDC 3000, ABB MasterPiece, and other legacy platforms. Contact us with your part number.

WhatsApp Prefilled Inquiry Email [email protected] Phone +86 18359293191 Top Back To Top