GE IC697CMM711 Communications Coprocessor Module – Obsolete Series 90-70 Spare Part
GE Automation & Controls IC697CMM711 is listed for Series 90-70 RFQ review. Confirm quantity, condition and destination before quotation.
Model: IC660BBA100
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
| Parameter | Detail |
|---|---|
| Part Number | IC660BBA100 |
| Manufacturer | GE Fanuc Automation |
| Series | Series 90-70 (GE 90-70 PLC) |
| Module Type | Analog Input Module |
| Product Status | Discontinued / Obsolete – No longer in production |
| Compatible Systems | GE Fanuc Series 90-70 PLC racks; also used in legacy GE 90-30 hybrid configurations |
| Country of Origin | United States |
| Condition Available | New surplus / Tested refurbished (see QA section below) |
Note: Electrical parameters such as channel count, input range, and resolution are not published here to avoid inaccurate specifications. Please contact us for verified datasheet documentation.
The IC660BBA100 analog input module sits at a critical junction in these systems. It converts field-level analog signals — temperature, pressure, flow, level — into digital values the CPU can act on. There is no software patch for a failed analog input card. When this module fails and no replacement is available, the choice becomes binary: source the part, or shut down the process and begin an emergency migration under the worst possible conditions.
For plant managers and maintenance engineers operating aging GE Fanuc Series 90-70 infrastructure, the following approach has proven effective in extending system service life without triggering a full capital replacement cycle:
1. Conduct a critical spares audit. Identify every module type in your Series 90-70 racks. Cross-reference against GE Fanuc's discontinued parts list. Any module that is no longer manufactured and has no direct modern equivalent is a single-point-of-failure risk. The IC660BBA100 falls into this category.
3. Implement a rotation and testing protocol. Spare modules should be bench-tested annually. Electrolytic capacitors in modules manufactured in the 1990s and early 2000s have a finite service life. A module sitting in a cabinet for five years without testing may fail on installation precisely when it is needed most.
5. Negotiate a long-term supply agreement. If your facility operates multiple Series 90-70 systems, a standing arrangement with a specialized obsolete parts supplier eliminates the scramble during an emergency. Contact DriveKNMS to discuss reserved inventory arrangements.
This approach does not require capital approval for a system replacement. It requires only a maintenance budget line item and a disciplined procurement process. For facilities with 5–10 years of planned operational life remaining on their current automation infrastructure, it is the most cost-effective path available.
Sourcing an obsolete module from an unverified channel carries real risk. A module that fails on installation — or worse, fails intermittently in service — creates a worse situation than the original fault. DriveKNMS applies a 5-step quality process to all obsolete modules before dispatch review:
Step 1 – Visual and mechanical inspection. All connectors, backplane pins, and PCB surfaces are examined for corrosion, physical damage, and evidence of prior repair or modification.
Step 2 – Electrolytic capacitor assessment. Capacitor aging is the primary failure mode in modules of this era. We check for visible bulging, electrolyte leakage, and where test equipment permits, capacitance and ESR values against specification.
Step 3 – Firmware version verification. The firmware revision is read and documented. This information is provided to the customer prior to shipment to confirm compatibility with their system configuration.
Step 4 – Functional power-on test. Where test fixtures are available for the module type, a power-on test is conducted to verify basic operational status.
Step 5 – Anti-static packaging and documentation. Modules are packaged in ESD-safe materials with a condition report. Traceability documentation is included where available.
The IC660BBA100 is a direct drop-in replacement for the original module position in any Series 90-70 rack. No hardware modifications to the rack or backplane are required. No PLC program changes are necessary — the replacement module assumes the same I/O addressing as the failed unit. There is no engineering labor cost associated with the swap beyond the physical installation and a system restart verification.
This is the fundamental economic argument for sourcing a like-for-like replacement rather than pursuing a migration: the engineering cost of a drop-in replacement is measured in hours. The engineering cost of a control system migration is measured in months. For a facility under production pressure, that difference is not abstract — it is the difference between a maintenance event and a capital project.
Can you source other Series 90-70 modules?
Yes. DriveKNMS maintains inventory across the GE Fanuc Series 90-70 product range, including CPU modules, power supplies, discrete I/O, and communications modules. Contact us with your full bill of materials for a consolidated quote.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.