GE IC697ALG230L Analog Input Module – Obsolete Series 90-70 Spare Part

Model: IC697ALG230L

Brand GE Fanuc
Series Series 90-70
Model IC697ALG230L
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

GE IC697ALG230L Analog Input Module – Obsolete Series 90-70 Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Parameter Detail
Part Number IC697ALG230L
Manufacturer GE Fanuc Automation
Series Series 90-70 PLC
Module Type Analog Input Module
Input Channels 16 single-ended / 8 differential analog inputs
Input Signal Range ±10V DC, 0–10V DC, 4–20mA (field selectable)
Resolution 12-bit
Backplane Compatibility GE Series 90-70 rack (IC697CHS750, IC697CHS782, IC697CHS790)
Discontinuation Status Officially discontinued by GE Fanuc / Emerson; no longer in production
Country of Origin United States

Solving the Discontinued Hardware Crisis

The GE Series 90-70 platform was the backbone of industrial automation across power generation, oil & gas, water treatment, and discrete manufacturing for over two decades. Thousands of these systems remain in active service today — not because operators are unaware of the discontinuation, but because the cost and risk of replacement outweigh the cost of maintenance.

The IC697ALG230L sits at a critical junction in these systems: it is the interface between field instrumentation — pressure transmitters, flow meters, temperature sensors — and the PLC's control logic. A failed module does not merely cause a fault; it blinds the controller to process conditions, triggering shutdowns or, worse, undetected process deviations.

Facilities running Series 90-70 systems face a documented supply chain gap. GE Fanuc transferred the product line to Emerson, and support has progressively narrowed. Sourcing IC697ALG230L units through standard distribution channels is no longer viable. The secondary market — when properly vetted — is the only practical source. DriveKNMS operates specifically within this space, maintaining inventory of hard-to-find modules for facilities that require continuity without system-wide replacement.

How to extend your Series 90-70 system life by 5–10 years without a full migration:

Condition & Reliability Assurance

Every IC697ALG230L unit shipped by DriveKNMS passes a structured 5-step inspection protocol before dispatch. This process was developed specifically for aging industrial electronics where standard functional testing is insufficient.

  1. Electrolytic Capacitor Inspection: All electrolytic capacitors are visually inspected for bulging, leakage, and ESR degradation. Capacitors showing any sign of aging are flagged for replacement before the unit is cleared.
  2. Firmware Version Verification: The module firmware is read and documented. Compatibility with the customer's CPU revision is confirmed prior to shipment where the CPU model is provided.
  3. Pin and Connector Corrosion Check: All backplane connector pins and field wiring terminals are inspected under magnification for oxidation, corrosion, and mechanical damage. Affected pins are cleaned or the unit is rejected.
  4. Functional Analog I/O Test: Each input channel is exercised across its full signal range. Output readings are compared against calibration references to confirm accuracy within specification.
  5. Final Documentation: A test record is generated for each unit, including inspection date, technician ID, firmware version, and test results. This record ships with the unit.

Key Features for System Maintenance

  • Drop-in replacement: The IC697ALG230L installs directly into any Series 90-70 rack slot without mechanical modification. No new mounting hardware, no rack reconfiguration.
  • No reprogramming required: The module operates under the existing PLC program. Channel configuration is stored in the CPU, not the module. Replacement does not require a programmer or software changes in standard configurations.
  • Avoids engineering reconstruction costs: A full analog I/O subsystem redesign using current-generation hardware requires I/O mapping changes, HMI tag updates, loop tuning verification, and process re-validation. A direct replacement with IC697ALG230L eliminates all of these costs.
  • Maintains process continuity: Because the replacement module is electrically and functionally identical to the original, field wiring, calibration records, and alarm setpoints remain valid without modification.

How do I know the unit is genuine and not counterfeit?
Every unit is inspected for authentic GE Fanuc markings, correct PCB layout, and genuine component population. Units that do not pass authenticity verification are not sold. We do not sell units of unknown origin without disclosure.

Should I buy more than one unit?
For any facility running a Series 90-70 system in a production-critical application, holding at least two IC697ALG230L spares is a defensible maintenance strategy. The module is no longer manufactured. Current secondary market availability will continue to decline. The cost of a second spare unit is negligible compared to the cost of an emergency sourcing effort during a production stoppage.

Can you source other Series 90-70 modules?
Yes. DriveKNMS maintains inventory across the Series 90-70 product line, including CPU modules, power supplies, discrete I/O, and communications modules. Contact us with your full BOM for availability.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top