Metso PDP Series Modules - PDP406

Model: PDP406

Brand Metso
Series PDP Series
Model PDP406
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Metso PDP Series Technical Notes

The Evolution of PDP Series Architecture

The PDP series emerged from Metso's transition from centralized PLC architectures toward fully distributed control in the late 1990s. Early variants such as the PDP401 and PDP402 operated on proprietary Metso fieldbus backplanes with limited inter-module bandwidth, targeting single-loop and small multi-loop control applications. The introduction of the PDP406 marked a significant architectural shift: expanded processing capacity, support for IEC 61131-3 function block programming, and compatibility with Metso DNA R5 and later software releases.

Compatibility note: PDP modules are backplane-specific. Cross-generation substitution requires firmware version alignment and, in some cases, DNA configuration database updates. Engineers planning module replacements must verify DNA software release compatibility before procurement.

Metso PDP Series Full Catalog & Functionalities (SKU List)

Controllers & Processing Units

  • PDP401: Single-loop distributed processing unit, early DNA architecture, serial fieldbus.
  • PDP402: Dual-loop controller module, enhanced scan rate over PDP401, legacy backplane.
  • PDP404: Mid-range processing unit, IEC 61131-3 compatible, DNA R4 baseline.
  • PDP406: Standard distributed processing unit, DNA R5 compatible, expanded memory.
  • PDP408: High-capacity controller, multi-loop support, redundant CPU option.
  • PDP410: Advanced processing unit, Ethernet supervisory port, DNA R6 compatible.
  • PDP412: Latest-generation PDP controller, dual-port Ethernet, enhanced diagnostics.

Digital I/O Modules

  • PDP421: 16-channel digital input module, 24 VDC, isolated, DIN rail mount.
  • PDP422: 16-channel digital output module, relay contact, 2A per channel.
  • PDP423: 32-channel DI module, high-density, grouped commons, DNA bus compatible.
  • PDP424: 32-channel DO module, transistor output, short-circuit protected.

Analog I/O Modules

  • PDP431: 8-channel analog input, 4–20 mA / 0–10 V selectable, 12-bit resolution.
  • PDP432: 8-channel analog output, 4–20 mA, 12-bit DAC, loop-powered option.
  • PDP433: 16-channel AI module, high-resolution 16-bit, HART pass-through capable.
  • PDP434: 4-channel AO module, 16-bit DAC, HART communication support.

Communication & Fieldbus Adapters

  • PDP451: PROFIBUS DP master adapter, up to 12 Mbit/s, 126-node support.
  • PDP452: Modbus RTU/TCP gateway module, dual-port, configurable baud rate.
  • PDP453: FOUNDATION Fieldbus H1 coupler, 31.25 kbit/s, segment-isolated.

Power Supply Modules

  • PDP461: 24 VDC backplane power supply, 10A output, redundancy-ready.
  • PDP462: Redundant PSU module, hot-swap capable, status LED and relay alarm output.

Quality Control for the PDP Series Range

PDP series modules incorporate complex multi-layer backplane connectors and proprietary DNA fieldbus transceivers that require specialized test procedures beyond standard bench power-on verification. DriveKNMS applies the following protocol to all PDP modules prior to dispatch:

  • Backplane connector inspection: Pin-by-pin continuity and contact resistance measurement using calibrated fixtures matched to Metso backplane specifications.
  • Functional loop test: Each module is installed in a live DNA test rack running the corresponding firmware version. I/O channels are exercised across full signal range (0–20 mA, 0–10 V, relay actuation) and verified against factory tolerance bands.
  • Fieldbus communication validation: For communication adapter modules (PDP451–PDP453), PROFIBUS, Modbus, and FF H1 segment integrity is verified using protocol analyzers.
  • Burn-in cycle: Modules undergo a minimum 48-hour powered burn-in at ambient temperature to screen for latent component failures.
  • Firmware version logging: Firmware revision is recorded and supplied with each module to ensure compatibility documentation is available for the receiving plant's engineering team.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top