Model: 100 PA/133.32 624A12TBC KK5002C 1900K1-1018 92-005649-0X, CENTON CPCB-00401 20-005650-02

Brand MKS Instruments
Series Baratron 624
Model 100 PA/133.32 624A12TBC KK5002C 1900K1-1018 92-005649-0X, CENTON CPCB-00401 20-005650-02
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

MKS Baratron 624 Series: Comprehensive Module Range and Technical Overview

The MKS Baratron 624 series capacitance manometer is a precision absolute pressure transducer deployed across the most demanding process environments in global heavy industry — semiconductor fabrication, chemical vapor deposition (CVD), thin-film coating, nuclear fuel processing, petrochemical refining, and pharmaceutical manufacturing. The 624 series operates on the capacitance sensing principle: a tensioned Inconel or Hastelloy diaphragm deflects under process pressure, altering the capacitance between the diaphragm and a fixed reference electrode. This signal is conditioned into a linear DC voltage output (0–10 VDC or 0–5 VDC), providing gas-species-independent, absolute pressure measurement across ranges from 0.001 Torr to 1000 Torr.

Installed in tens of thousands of process chambers worldwide, the 624 series has become the de facto reference standard for vacuum process control in semiconductor OEM equipment from Applied Materials, Lam Research, Tokyo Electron, and ASML. Its heated-body variants (at 45°C, 100°C, and 200°C) prevent condensation of reactive process gases, making it the preferred sensor in ALD, PECVD, and etch tool platforms.

The Evolution of Baratron 624 Architecture

MKS Instruments introduced the Baratron capacitance manometer concept in the 1960s, establishing the foundational measurement architecture that persists in the 624 series today. The product line has passed through several distinct engineering generations:

First Generation (1970s–1980s): Analog signal conditioning with discrete component circuitry. Models such as the 122A and 170M established the Baratron brand in research vacuum systems. Temperature stability was limited; heated-body options were not yet standard.

Second Generation (1990s): Introduction of the 622 and 624 platform with integrated ASIC signal processing. The 624 replaced the 622 as the primary OEM-grade transducer. Full-scale ranges were standardized at 1, 10, 100, 1000 Torr. The 45°C heated body became standard for semiconductor applications. Connector standardization (15-pin D-sub) enabled direct integration with MKS 247, 651, and 252 flow and pressure controllers.

Third Generation (2000s–2010s): Introduction of the 628B and 629B as high-accuracy variants. The 624 series received enhanced EMI shielding, improved zero stability (<0.02% FS/°C), and extended cable options. The CENTON signal conditioning board (CPCB-00401, 20-005650-02) was introduced as a replaceable internal PCB assembly, enabling field-level repair without full transducer replacement.

Current Status (2020s): The 624 series is in the mature/end-of-active-production phase for many sub-variants. MKS has transitioned new designs toward the 626C and 627D platforms with digital (RS-485/DeviceNet) interfaces. However, the installed base of 624-series transducers in legacy semiconductor and industrial process tools remains enormous. Replacement demand for 624A, 624B, and associated PCB assemblies (KK5002C, CPCB-00401) is sustained by the multi-decade service life of process equipment in which they are embedded.

Baratron 624 Full Catalog & Functionalities (SKU List)

Pressure Transducers — Absolute, Capacitance Type

  • 624A12TBC: 100 Torr full-scale, 45°C heated body, 15-pin D-sub, 0–10 VDC output, Inconel diaphragm.
  • 624A13TBC: 1000 Torr full-scale, 45°C heated body, 15-pin D-sub, 0–10 VDC output, standard process fitting.
  • 624A11TBC: 10 Torr full-scale, 45°C heated body, 15-pin D-sub, 0–10 VDC output, Inconel diaphragm.
  • 624B12TBC: 100 Torr full-scale, 100°C heated body, enhanced chemical resistance, Hastelloy wetted parts.
  • 624B13TBC: 1000 Torr full-scale, 100°C heated body, Hastelloy diaphragm, corrosive gas service.
  • 624C12TBC: 100 Torr full-scale, 200°C heated body, for high-condensation-risk process gases (TEOS, HMDS).
  • 624C13TBC: 1000 Torr full-scale, 200°C heated body, high-temperature process compatibility.
  • 624A10TBC: 1 Torr full-scale, 45°C heated body, ultra-low pressure range, semiconductor etch applications.
  • 624B10TBC: 1 Torr full-scale, 100°C heated body, corrosive low-pressure process gas measurement.
  • 624A14TBC: 10,000 Torr (atmospheric+) full-scale, 45°C heated body, high-pressure process monitoring.

Internal PCB / Signal Conditioning Assemblies

  • KK5002C: Internal capacitance-to-voltage signal conditioning PCB assembly for 624 series; primary repair component for zero/span drift faults.
  • CPCB-00401 (CENTON): Replacement signal conditioning board, cross-compatible with KK5002C function; used in field repair of 624A/B/C bodies.
  • 20-005650-02: PCB sub-assembly revision 02 for CENTON CPCB-00401; addresses EMI susceptibility found in earlier revisions.
  • 92-005649-0X: Cable/connector harness assembly for 624 series internal wiring; X denotes revision suffix (0A, 0B, 0C).
  • 1900K1-1018: Heater element assembly for 45°C heated-body 624 variants; field-replaceable thermal component.

Accessories & Mounting Hardware

  • 100 PA/133.32: Pressure range designation — 100 Pascal absolute (equivalent to 133.32 mTorr); identifies the calibrated full-scale range of this specific transducer unit.

Sourcing Hard-to-Find & Obsolete Baratron 624 Parts

As MKS Instruments has progressively migrated its active product portfolio toward the 626C and 627D digital platforms, procurement of 624-series components — particularly internal PCB assemblies (KK5002C, CPCB-00401), heater elements (1900K1-1018), and cable harnesses (92-005649-0X) — has become increasingly difficult through standard distribution channels.

DriveKNMS maintains a dedicated inventory of MKS Baratron 624 series transducers and sub-assemblies sourced from decommissioned semiconductor tool lots, OEM overstock, and controlled secondary market channels. Our procurement team cross-references part numbers against MKS engineering change notices (ECNs) to ensure revision compatibility before shipment.

For end-users operating legacy Applied Materials Centura, Lam Research Versys, or TEL Trias platforms where 624-series transducers are embedded in the original tool BOM, DriveKNMS provides like-for-like replacement units with documented calibration traceability. We also supply the CENTON CPCB-00401 and 20-005650-02 PCB assemblies as standalone repair components, enabling cost-effective refurbishment of existing transducer bodies rather than full unit replacement.

Lifecycle extension contracts are available for facilities requiring guaranteed 624-series availability over a 3–5 year maintenance horizon.

Quality Control for the Baratron 624 Range

Each MKS Baratron 624 unit processed by DriveKNMS undergoes a structured verification protocol before dispatch:

  • Diaphragm integrity check: Helium leak test at process-side port to confirm diaphragm seal integrity (<1×10⁻⁹ atm·cc/sec).
  • Zero and span calibration: Full-scale output verified against NIST-traceable reference standard at 0 Torr (zero) and rated full-scale pressure (span). Tolerance: ±0.25% FS.
  • Heated body thermal verification: For 45°C, 100°C, and 200°C variants, heater element continuity and setpoint stability are confirmed over a 30-minute thermal soak cycle.
  • PCB assembly functional test: KK5002C and CPCB-00401 boards are bench-tested for capacitance bridge balance, output linearity, and EMI rejection before installation or standalone shipment.
  • Connector and cable inspection: 15-pin D-sub connectors and internal harnesses (92-005649-0X) are inspected for pin integrity, insulation resistance (>100 MΩ at 500 VDC), and correct wiring against MKS schematic revision.
  • Documentation package: Each unit ships with a test report, revision identification, and cross-reference to the original MKS part number and applicable ECN.
WhatsApp Prefilled Inquiry Email [email protected] Phone +86 18359293191 Top Back To Top