Schneider Electric MA0186100 Coaxial Cable Splitter – Obsolete Telemecanique Spare Part

Model: MA0186100

Series Telemecanique
Model MA0186100
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Schneider Electric MA0186100 Coaxial Cable Splitter – Obsolete Telemecanique Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Solving the Discontinued Hardware Crisis

The MA0186100 sits at a structural chokepoint in Fipio/Fipway network topology. This splitter enables the star or branch wiring configurations that connect field devices — drives, sensors, valve actuators — back to the PLC CPU. Without it, the segment cannot be reconstructed using off-the-shelf coaxial components; the impedance matching and connector geometry are proprietary to the Telemecanique fieldbus standard.

Schneider Electric officially discontinued the Fipway/Fipio product line as part of its migration strategy toward Ethernet-based architectures (Modbus TCP, EtherNet/IP). Replacement parts were removed from the standard catalog years ago. For factories still running TSX Premium or Modicon 984 controllers — systems with 15 to 25 years of embedded process logic, calibrated PID loops, and validated safety interlocks — the cost of retiring the control system to eliminate this single dependency is disproportionate. The MA0186100 is the lower-cost path: replace the failed component, restore the network, and extend the asset's productive life by 5 to 10 years without touching the control logic.

Condition & Reliability Assurance

All MA0186100 units supplied by DriveKNMS pass a structured 5-step inspection protocol before dispatch:

  • Step 1 – Visual and mechanical inspection: Housing integrity, connector body condition, and labeling authenticity are verified against original Telemecanique documentation.
  • Step 2 – Electrolytic capacitor assessment: Where applicable, internal passive components are inspected for signs of electrolyte leakage, bulging, or ESR degradation common in parts stored beyond 10 years.
  • Step 3 – Pin and contact inspection: All coaxial connector pins are examined under magnification for oxidation, corrosion, or mechanical deformation. Affected contacts are cleaned or the unit is rejected.
  • Step 4 – Impedance and continuity verification: Electrical continuity and coaxial impedance characteristics are tested to confirm the splitter meets the signal integrity requirements of the Fipio/Fipway standard.
  • Step 5 – Firmware / revision marking check: Hardware revision markings are recorded and disclosed to the buyer prior to shipment to ensure compatibility with the target network revision.

Key Features for System Maintenance

  • Drop-in replacement: The MA0186100 installs directly into existing Telemecanique fieldbus wiring without modification to cable runs, termination resistors, or network addressing.
  • No reprogramming required: Replacing this passive network component does not alter PLC program memory, I/O mapping, or device addressing. Restart the segment and the network resumes normal operation.
  • Avoids engineering reconstruction costs: Retaining the existing Fipio/Fipway architecture eliminates the need for fieldbus migration projects, which typically require a controls engineer, a commissioning team, and a planned production shutdown of 2 to 6 weeks.
  • Long-term sparing strategy: For facilities operating multiple Fipio/Fipway segments, holding 2 to 4 units of the MA0186100 in bonded storage provides a statistically adequate buffer against unplanned failure over a 5 to 10 year horizon.

Q: Can this part be used with Modicon Quantum or M340 controllers?
A: The MA0186100 is specific to Fipio/Fipway network infrastructure. Modicon Quantum and M340 platforms use different fieldbus and Ethernet architectures and are not compatible with this component.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.