Schneider TSX3721001 Modular Base Controller – Momentum Series
Schneider Electric TSX3721001 is listed for Momentum Series RFQ review. Confirm quantity, condition and destination before quotation.
Model: MT08N1
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
The following SKUs represent verified models within the Schneider Electric Masterpact MT series, organized by frame rating and pole configuration. Each entry reflects a distinct catalog reference with defined current rating, breaking capacity, and mounting type.
MT06H1: 630 A, H-frame (70 kA), fixed, 3-pole, standard incomer/feeder ACB.
MT06H13: 630 A, H-frame, draw-out, 3-pole, with MicroLogic 5.3 E trip unit.
MT06N1: 630 A, N-frame (50 kA), fixed, 3-pole, general-purpose distribution.
MT06N13: 630 A, N-frame, draw-out, 3-pole, MicroLogic 5.3 E, MODBUS ready.
MT08N1: 800 A, N-frame (50 kA), fixed, 3-pole, main incomer for MCC and MDB.
MT08N13: 800 A, N-frame, draw-out, 3-pole, MicroLogic 5.3 E trip unit.
MT08H1: 800 A, H-frame (70 kA), fixed, 3-pole, high breaking capacity feeder.
MT08H13: 800 A, H-frame, draw-out, 3-pole, MicroLogic 5.3 E, EcoStruxure compatible.
MT10N1: 1000 A, N-frame, fixed, 3-pole, standard bus coupler and incomer duty.
MT10N13: 1000 A, N-frame, draw-out, 3-pole, MicroLogic 5.3 E, MODBUS/Ethernet.
MT10H1: 1000 A, H-frame (70 kA), fixed, 3-pole, high-fault-level incomer.
MT12N1: 1250 A, N-frame, fixed, 3-pole, large feeder and bus section protection.
MT12N13: 1250 A, N-frame, draw-out, 3-pole, MicroLogic 5.3 E trip unit.
MT16N1: 1600 A, N-frame, fixed, 3-pole, main incomer for large LV switchboards.
MT16H1: 1600 A, H-frame (70 kA), fixed, 3-pole, high breaking capacity main incomer.
MT20N1: 2000 A, N-frame, fixed, 3-pole, large distribution and bus coupler duty.
MT20H1: 2000 A, H-frame, fixed, 3-pole, high-fault-level 2000 A incomer.
MT25N1: 2500 A, N-frame, fixed, 3-pole, heavy industrial main incomer.
MT32N1: 3200 A, N-frame, fixed, 3-pole, primary incomer for large LV substations.
MT40N1: 4000 A, N-frame, fixed, 3-pole, utility-scale LV main incomer.
Air circuit breakers in the Masterpact MT series incorporate complex mechanical and electronic subsystems — including the draw-out cradle mechanism, stored-energy spring charging motor, MicroLogic X trip unit, and Bluetooth/Ethernet communication module — each of which requires dedicated verification procedures. DriveKNMS applies the following test protocol to all MT-series units processed through its facility: (1) Mechanical operation test: minimum 5 open/close cycles under no-load conditions to verify spring charging mechanism, racking mechanism engagement, and auxiliary contact sequencing; (2) Trip unit functional test: injection of simulated overcurrent, short-circuit, and earth fault signals via a calibrated secondary injection test set to verify MicroLogic X protection thresholds; (3) Insulation resistance test: 1000 V DC Megger test across all pole pairs and pole-to-frame, minimum 100 MΩ acceptance criterion; (4) Contact resistance measurement: micro-ohmmeter test on main current path, acceptance per IEC 60947-2 manufacturer limits; (5) Communication interface verification: MODBUS RTU and Ethernet/IP polling test to confirm trip unit data register integrity. All test results are documented and supplied with each unit shipment.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.