Siemens 6ES7132-6BH00-0AA0 Digital Output Module – ET 200SP Spare Part

Model: 6ES7132-6BH00-0AA0

Brand Siemens
Model 6ES7132-6BH00-0AA0
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens 6ES7132-6BH00-0AA0 Digital Output Module – ET 200SP Obsolete Spare Part

DriveKNMS reviews sourcing status and documentation for this model during RFQ handling before quotation.

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Parameter Value
Part Number 6ES7132-6BH00-0AA0
Brand Siemens
Series SIMATIC ET 200SP
Module Type Digital Output Module
Number of Outputs 8 DO
Output Voltage 24 V DC
Output Current per Channel 0.5 A
Country of Origin Germany
Discontinuation Status Discontinued / Obsolete – No longer in active Siemens production. Replacement sourcing required from authorized aftermarket suppliers.
Compatible Base Unit BU Type A0 (e.g. 6ES7193-6BP00-0BA0)
Compatible Systems SIMATIC ET 200SP distributed I/O, S7-1200, S7-1500 via PROFINET/PROFIBUS

Solving the Discontinued Hardware Crisis

Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.

Siemens has since transitioned its ET 200SP portfolio, and the 6ES7132-6BH00-0AA0 is no longer manufactured. For facilities still running this hardware, the discontinuation creates a specific operational risk: a single failed module with no replacement on hand can halt an entire I/O station, taking down all field devices connected to that rack segment.

The engineering reality is that newer ET 200SP output modules are not always backward-compatible at the firmware or configuration level without project re-engineering in TIA Portal. For plants running older TIA Portal versions or legacy Step 7 configurations, a like-for-like replacement is the only path that avoids a software re-validation cycle.

How to extend your automation asset life by 5–10 years without a full system overhaul:

For plant managers facing pressure to justify capital expenditure on aging infrastructure: the math is straightforward. A proactive spare parts strategy for an ET 200SP line costs 1–3% of the line's replacement value annually. A reactive strategy — sourcing emergency parts at premium prices or funding a forced migration — routinely costs 20–40% of replacement value in a single incident.

Condition & Reliability Assurance

All 6ES7132-6BH00-0AA0 units supplied by DriveKNMS pass a structured 5-step quality process before dispatch review:

  1. Visual Inspection: Full external examination for physical damage, pin corrosion, connector wear, and label integrity. Units with corroded or bent I/O pins are rejected at this stage.
  2. Electrolytic Capacitor Assessment: Internal capacitors are evaluated for signs of aging, bulging, or electrolyte leakage — a primary failure mode in modules stored beyond 10 years.
  3. Firmware Version Verification: The firmware revision is read and documented. Customers are informed of the exact firmware version prior to shipment so compatibility with their TIA Portal project can be confirmed.
  4. Functional Output Test: Each output channel is exercised under load to verify switching integrity and confirm no latent transistor degradation.
  5. Packaging & ESD Protection: Units are packed in anti-static bags with desiccant and rigid outer packaging to prevent transit damage and moisture ingress.

Key Features for System Maintenance

  • Drop-in replacement: The 6ES7132-6BH00-0AA0 installs directly into any compatible ET 200SP BU Type A0 base unit. No wiring changes, no hardware re-engineering.
  • No reprogramming required: The module is recognized automatically by the existing TIA Portal or Step 7 hardware configuration, provided the project was originally built with this order number. Maintenance technicians can complete the swap without engineering department involvement.
  • Avoids forced migration costs: Substituting a non-identical module — even within the ET 200SP family — can trigger a hardware configuration change that requires project re-download, re-validation, and in safety-rated lines, re-certification. A like-for-like replacement eliminates this risk entirely.
  • Preserves existing wiring infrastructure: Field wiring connected to the base unit remains undisturbed. Swap time for a trained technician is under 15 minutes.

Q: Can you support multi-unit or repeat RFQ requests?
A: Yes. Send the model list, target quantity and destination so DRIVEKNMS can review sourcing options and quote the requirement as a project RFQ.

Q: How do I confirm compatibility with my existing system?
A: Provide your TIA Portal project hardware configuration or the existing module's order number and firmware version. Our technical team will confirm compatibility before dispatch review.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top