Siemens 6GK5308-2GG10-2AA2 IE Switch – Obsolete SCALANCE X300 Spare Part

Model: 6GK5308-2GG10-2AA2

Brand Siemens
Model 6GK5308-2GG10-2AA2
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens 6GK5308-2GG10-2AA2 IE Switch – Obsolete SCALANCE X300 Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Part Number 6GK5308-2GG10-2AA2
Product Family SCALANCE X300 (X308-2)
Manufacturer Siemens AG
Country of Origin Germany
Discontinuation Status Discontinued / Obsolete – no longer in Siemens active production
Port Configuration 8 × 10/100/1000 Mbps RJ45 + 2 × SFP Gigabit combo ports
Switching Standard IEEE 802.3, 802.3u, 802.3ab, 802.1Q (VLAN), 802.1D (STP/RSTP)
Management Managed – Web, SNMP, CLI
Power Supply Input 24 V DC (redundant power input supported)
Operating Temperature -40 °C to +70 °C
Protection Rating IP30
Mounting DIN rail / S7-300 rail compatible
Compatible Systems Siemens S7-300, S7-400, SIMATIC PCS 7, TIA Portal networks, SINEC H1 legacy infrastructure

Solving the Discontinued Hardware Crisis

The SCALANCE X300 series was a cornerstone of Siemens industrial network design throughout the 2000s and 2010s. Facilities that standardized on this platform — particularly those running SIMATIC PCS 7 distributed control systems or S7-400-based safety instrumented systems — built their network topology around the specific port density, VLAN segmentation behavior, and PROFINET conformance class of the X308-2. No current-generation Siemens switch is a direct drop-in replacement without network reconfiguration.

The practical consequence: when a 6GK5308-2GG10-2AA2 fails, the path of least disruption is identical hardware replacement. Reconfiguring a managed switch in a validated PROFINET environment — particularly in pharmaceutical, chemical, or automotive manufacturing — requires documented change control, re-validation, and in regulated industries, potential regulatory notification. The cost of that process dwarfs the cost of sourcing a spare unit. Facilities that carry one or two units of this switch in strategic reserve eliminate that risk entirely. DriveKNMS sources, inspects, and holds this inventory for exactly that operational reality.

Condition & Reliability Assurance

Discontinued hardware sourced from secondary markets carries age-related failure risks that new production units do not. DriveKNMS applies a 5-step inspection protocol to every unit of the 6GK5308-2GG10-2AA2 before it is offered for sale:

  • Step 1 – Electrolytic Capacitor Assessment: Capacitor aging is the primary failure mode in switches of this generation. Each unit undergoes ESR (Equivalent Series Resistance) measurement on all electrolytic capacitors. Units with degraded capacitors are rejected or recapped before sale.
  • Step 2 – Firmware Version Verification: The installed firmware version is documented and compared against the last Siemens-released version for this model. Customers receive full firmware documentation with each unit.
  • Step 3 – Pin and Connector Inspection: All RJ45 ports, SFP slots, and power terminals are inspected under magnification for corrosion, mechanical deformation, or contact oxidation.
  • Step 4 – Functional Network Test: Each unit is powered and tested for full port-to-port switching function, VLAN operation, and management interface accessibility before packaging.
  • Step 5 – Cosmetic and Label Verification: Serial number, production date code, and Siemens CE/UL markings are verified for authenticity. Units with tampered or missing labels are rejected.

Key Features for System Maintenance

Q: How do I confirm the unit is genuine Siemens hardware, not a counterfeit?
A: Every unit sold by DriveKNMS includes serial number documentation. Siemens serial numbers for SCALANCE X300 units follow a verifiable format, and we provide the production date code with each sale. Units that fail our authenticity check are not offered for sale under any condition.

Q: Can you supply multiple units for a long-term spare parts program?
A: Contact us directly to discuss volume availability and long-term reserve agreements. We work with plant engineering and procurement teams to structure spare parts programs for discontinued Siemens network hardware.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top