Yaskawa YPHT11014-1A Circuit Board – Obsolete Drive Control Spare Part
Yaskawa YPHT11014-1A is listed for Servo Drives RFQ review. Confirm quantity, condition and destination before quotation.
Model: NX100JZRCR-NPP01-1
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
Extending Asset Life 5–10 Years: A Practical Strategy for NX100 Installations
1. Identify single-point-of-failure components. The teach pendant, the JZNC-NRK01-1 CPU board, and the JZNC-NIO01-1 I/O board are the three components most likely to cause a full cell shutdown when they fail. None are available through Yaskawa's current distribution network.
3. Source from verified secondary-market specialists. Not all surplus inventory is equal. Units that have been stored improperly — high humidity, temperature cycling, or electrostatic exposure — may fail within weeks of installation. Verify that your supplier performs incoming inspection and can provide traceability documentation.
4. Document firmware versions before any swap. NX100 system software versions must match between the controller and the pendant. Confirm the firmware revision on your existing pendant before ordering a replacement, and communicate that version to your supplier.
DriveKNMS applies a 5-step incoming inspection protocol to all obsolete teach pendants before they are offered for sale:
Step 1 – Visual and Mechanical Inspection: Housing integrity, cable condition, connector pin inspection for corrosion, bending, or contamination. Units with physical damage to the emergency stop circuit or deadman switch mechanism are rejected.
Step 2 – Electrolytic Capacitor Assessment: Internal capacitors on legacy pendant PCBs are a known failure mode after extended storage. We inspect for visible bulging, electrolyte leakage, and ESR deviation where test access permits.
Step 3 – Firmware Version Verification: The firmware revision is read and documented. This information is provided to the buyer prior to shipment so compatibility with the target controller can be confirmed.
Step 4 – Functional Power-On Test: Where test equipment is available, the pendant is powered and basic display, keypad, and communication functions are verified.
Step 5 – ESD-Safe Packaging and Documentation: Units are packed in anti-static bags with desiccant, boxed with foam protection, and shipped with an inspection record. Storage and handling instructions are included.
The NX100JZRCR-NPP01-1 is a direct, drop-in replacement for the original pendant fitted to NX100 controllers. No controller re-programming is required. No modifications to the robot's job files, system parameters, or I/O configuration are necessary. The replacement procedure is a physical swap followed by a firmware version confirmation — a task within the competency of any qualified robot maintenance technician. This eliminates the engineering cost associated with platform migration: no new safety validation, no PLC interface re-mapping, no operator retraining. The existing production programs, calibration data, and tool definitions remain intact on the controller. The cell returns to production in hours, not weeks.
Q: How do I know the unit is genuine Yaskawa and not a counterfeit?
A: All units sourced by DriveKNMS are inspected for OEM labeling, part number markings, and construction consistency with known-genuine examples. We do not handle units of uncertain provenance. Traceability documentation is available on request.
Q: Can this pendant be used with DX100 or DX200 controllers?
A: No. The NX100JZRCR-NPP01-1 is specific to the NX100 controller platform. It is not compatible with Yaskawa's DX100, DX200, or YRC1000 series controllers.