Allen-Bradley 1791 Block I/O Modules – 1791-OB16

Model: 1791-OB16

Series 1791-OB16
Model 1791-OB16
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley 1791 Series Technical Notes

The Allen-Bradley 1791 Block I/O series, manufactured by Rockwell Automation, is a distributed I/O platform engineered for direct field-level installation in industrial environments. Deployed extensively across global heavy industry — including petrochemical refineries, nuclear power auxiliary systems, offshore platforms, and continuous-process chemical plants — the 1791 series eliminates the need for centralized I/O enclosures by mounting directly at the machine or process skid. Its IP65/NEMA 4 rated housing and integrated terminal block design reduce wiring infrastructure costs and improve signal integrity over long cable runs. The series interfaces natively with Allen-Bradley PLC-5, SLC 500, and ControlLogix processors via the 1771 I/O chassis or remote I/O (RIO) adapter links, making it a foundational component in legacy DCS and hybrid automation architectures that remain operational in facilities with 20–40 year asset lifecycles.

The Evolution of 1791 Architecture

The 1791 Block I/O platform was introduced by Allen-Bradley in the mid-1980s as a response to the industry demand for distributed, panel-free I/O in harsh environments. The first-generation modules communicated exclusively over the Allen-Bradley Remote I/O (RIO) link — a proprietary token-passing network operating at 57.6 Kbps, 115.2 Kbps, or 230.4 Kbps. These modules required a 1791-A1B or 1791-A2B adapter to bridge the RIO link to the block I/O backplane.

In the early 1990s, Rockwell expanded the series with analog variants (1791-IANA, 1791-IANA2) and combination discrete/analog modules to support process instrumentation loops alongside discrete machine control. The introduction of DeviceNet-compatible 1791D (BlockDN) variants in the late 1990s extended the platform's relevance into the fieldbus era, allowing integration with ControlLogix and CompactLogix systems via 1756-DNB or 1769-SDN scanner modules.

By the 2010s, the core 1791 RIO-based discrete modules entered the Rockwell Automation end-of-life cycle. Rockwell's published migration path directs users toward the 1734 POINT I/O and 1756 ControlLogix I/O platforms. However, due to the capital cost of full system replacement and the operational risk of modifying validated process control systems, the 1791 series remains in active service across a significant installed base. Compatibility constraints include: RIO link dependency on legacy PLC-5 or SLC 500 processors, fixed terminal block wiring that complicates hot-swap procedures, and firmware that is not field-upgradeable.

1791 Full Catalog & Functionalities (SKU List)

The following SKUs represent verified, commonly sourced models within the Allen-Bradley 1791 Block I/O series, classified by functional category:

Discrete Output Modules

  • 1791-OB16: 16-point 24VDC sourcing discrete output, RIO interface, IP65 housing
  • 1791-OB32: 32-point 24VDC sourcing discrete output, high-density field wiring
  • 1791-OV16: 16-point 120VAC discrete output, triac-switched, RIO link
  • 1791-OV32: 32-point 120VAC discrete output, panel-mount terminal block
  • 1791-OB16P: 16-point 24VDC protected output with diagnostics, short-circuit detection

Discrete Input Modules

  • 1791-IB16: 16-point 24VDC sinking discrete input, RIO interface
  • 1791-IB32: 32-point 24VDC sinking discrete input, high-density
  • 1791-IV16: 16-point 120VAC discrete input, optically isolated
  • 1791-IV32: 32-point 120VAC discrete input, RIO link compatible
  • 1791-IB16K: 16-point 24VDC input with keying, conformal-coated PCB

Combination I/O Modules

  • 1791-16A0: 16 discrete inputs / 16 discrete outputs, 24VDC, single block
  • 1791-16B0: 16-point combination I/O, 120VAC, RIO link
  • 1791-32A0: 32-point combination discrete I/O, 24VDC, high-density terminal

Analog Modules

  • 1791-IANA: 4-channel analog input (4–20 mA / 0–10V), 12-bit resolution, RIO link
  • 1791-IANA2: 8-channel analog input, 12-bit, dual-range, process instrumentation

Adapter / Communication Modules

  • 1791-A1B: Single-port RIO adapter, connects block I/O to Allen-Bradley RIO network
  • 1791-A2B: Dual-port RIO adapter, supports daisy-chain and star topology wiring

Sourcing Hard-to-Find & Obsolete 1791 Series Parts

Customers in the petrochemical, power generation, and water treatment sectors with validated control systems that cannot be migrated without regulatory re-qualification represent the primary use case for this service. DriveKNMS ships globally with full export documentation.

Quality Control for the 1791 Range

Each 1791 series module processed by DriveKNMS undergoes a structured inspection and functional test protocol specific to the block I/O architecture:

  • Visual Inspection: Terminal block integrity, housing seal condition, connector pin inspection, label legibility
  • Power-On Test: Module energized at rated supply voltage (24VDC or 120VAC per variant); status LED verification against expected state
  • I/O Point Functional Test: Each discrete I/O point individually exercised using a dedicated test fixture that simulates RIO adapter communication; output switching verified under resistive load; input thresholds verified against published specifications
  • Analog Channel Calibration (IANA variants): 4–20 mA loop calibration verified at 0%, 25%, 50%, 75%, and 100% of range; offset and gain error recorded against Rockwell published tolerance
  • RIO Communication Verification: Module integrated into a test rack with a 1747-SN or 1771-ASB adapter; discrete image table read/write confirmed at all three RIO baud rates
  • Burn-In: Modules operated under load for a minimum of 4 hours prior to final inspection

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top