Allen-Bradley 1791D Series Modules: 1791D-0B8P,

Model: 1791D-0B8P

Series 1791D Series
Model 1791D-0B8P
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley 1791D Series Technical Notes

Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.

The Evolution of 1791D Architecture

The 1791D series was introduced as part of Rockwell Automation's broader DeviceNet ecosystem expansion in the mid-1990s, designed to complement the 1747 SLC 500 and 1756 ControlLogix controller platforms. Early variants focused on discrete I/O — 8-point and 16-point digital input/output blocks — communicating over DeviceNet at 125 Kbps, 250 Kbps, or 500 Kbps baud rates. The architecture uses a sealed, IP67-rated housing on select models, enabling direct mounting in wet or wash-down environments without additional enclosures.

Over successive revisions, Rockwell expanded the catalog to include analog I/O variants (1791D-4C0 series), combination modules, and specialty blocks with configurable node addressing via rotary switches. Compatibility with RSNetWorx for DeviceNet configuration software remained consistent across all revisions, allowing engineers to use a single EDS-based commissioning workflow regardless of module generation. The series interfaces natively with 1756-DNB, 1747-SDN, and 1771-SDN scanner modules.

1791D Full Catalog & Functionalities (SKU List)

Digital Output Modules

  • 1791D-0B8P: 8-point 24VDC sourcing digital output block, DeviceNet, IP67, M12 connectors
  • 1791D-0B16P: 16-point 24VDC sourcing digital output block, DeviceNet, sealed housing
  • 1791D-0B8: 8-point 24VDC sinking digital output, open-style housing, DIN rail mount
  • 1791D-0B16: 16-point 24VDC sinking digital output, open-style, screw terminal
  • 1791D-0B32P: 32-point 24VDC sourcing digital output, high-density sealed block

Digital Input Modules

  • 1791D-8C0: 8-point 24VDC digital input block, DeviceNet, M12 sealed connectors
  • 1791D-16C0: 16-point 24VDC digital input, sealed housing, IP67
  • 1791D-8C0P: 8-point 24VDC digital input, PNP (sourcing), M12 connectors
  • 1791D-16C0P: 16-point 24VDC digital input, PNP sourcing, sealed block
  • 1791D-32C0: 32-point 24VDC digital input, high-density, open-style housing

Combination (Input/Output) Modules

  • 1791D-4C4D: 4-point DI / 4-point DO combination block, 24VDC, DeviceNet
  • 1791D-8C8D: 8-point DI / 8-point DO combination, sealed M12, IP67
  • 1791D-16C16D: 16-point DI / 16-point DO combination, high-density block

Analog I/O Modules

  • 1791D-4C0: 4-channel analog input, 4–20 mA / 0–10V configurable, DeviceNet
  • 1791D-2C2D: 2-channel analog input + 2-channel analog output combination block
  • 1791D-4V0: 4-channel analog voltage input, ±10V range, DeviceNet node

Sourcing Hard-to-Find & Obsolete 1791D Parts

All 1791D units sourced through DriveKNMS are subject to functional verification testing prior to shipment. Units are tested for DeviceNet node communication, I/O point integrity, and housing seal condition (on IP67 variants). Traceability documentation is provided on request for regulated industries (FDA, ATEX-adjacent environments).

Quality Control for the 1791D Range

The 1791D series presents specific QC challenges due to its sealed housing design and DeviceNet bus communication dependency. DriveKNMS applies the following verification protocol to all 1791D units:

  • DeviceNet Node Scan: Each unit is connected to a live DeviceNet segment and scanned via RSNetWorx. Node address assignment, EDS file match, and baud rate auto-detection are verified.
  • I/O Point Functional Test: All digital output points are activated sequentially under rated load (24VDC, rated current). Input points are verified with calibrated signal injection.
  • Analog Calibration Check (for 1791D-4C0 / 4V0 variants): 4–20 mA and voltage channels are tested at 0%, 50%, and 100% of rated range against a calibrated reference meter.
  • Housing Integrity Inspection: M12 connector threads, sealing gaskets, and locking mechanisms are inspected. IP67-rated units with compromised seals are flagged and not shipped.
  • Firmware Revision Logging: Where accessible, firmware revision is recorded and disclosed to the buyer prior to shipment.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top