ABB NAMC-11C
ABB NAMC-11C is listed for Controller Cards RFQ review. Confirm quantity, condition and destination before quotation.
Model: SMU-03 3HNA024411-001 OEW2-25-2MHCP E007310-050E 3HNA024966-001 3HNA011999-001
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
ABB's safety monitoring architecture for industrial robots has progressed through three distinct hardware generations within the IRC5 platform. The SMU-01 introduced hardware-based speed and position monitoring via dedicated FPGA logic. The SMU-02 added expanded I/O capacity and improved diagnostic coverage for Category 3 / PLd safety functions. The SMU-03 represents the mature revision: it integrates dual-channel monitoring circuits, expanded SafeMove compatibility, and a revised backplane connector layout (3HNA024411-001 board revision) that is not backward-compatible with SMU-01 mounting positions without a bracket adapter kit (3HNA011999-001).
The SMU-03 communicates with the main computer (DSQC639 / DSQC1000) via the IRC5 internal DeviceNet-derived backplane bus. Firmware is stored on the onboard flash and is updated via RobotWare installation — the module does not accept standalone firmware flashing. Units manufactured after 2014 carry the OEW2-25-2MHCP marking, indicating compliance with the revised EN ISO 10218-1:2011 machinery directive interpretation. The E007310-050E suffix denotes the specific PCB assembly variant used in the repair kit configuration, combining the main SMU-03 board with the associated relay output expansion sub-board (3HNA024966-001) and the mechanical mounting hardware set (3HNA011999-001).
The following SKUs represent verified components within the ABB SMU-03 ecosystem and associated IRC5 safety module range. Each entry reflects a distinct hardware assembly or sub-component with a defined functional role.
3HNA024411-001: SMU-03 main PCB assembly, dual-channel safety monitoring board
OEW2-25-2MHCP: Safety relay output module, 25mm DIN rail mount, 2-channel, IRC5 compatible
E007310-050E: PCB sub-assembly variant identifier for SMU-03 repair kit configuration
3HNA024966-001: Relay expansion sub-board for SMU-03, output contact extension
3HNA011999-001: Mechanical mounting bracket and hardware kit for SMU-03 installation
3HNA024411-002: SMU-03 revised board revision with updated conformal coating specification
3HNA006146-001: SMU-03 connector housing kit, backplane interface
3HNA015609-001: SMU-03 firmware carrier module (legacy RobotWare 5.x compatibility)
3HNA024412-001: SMU-03 front panel indicator assembly, LED status display board
3HNA024413-001: SMU-03 internal ribbon cable assembly, board-to-board interconnect
3HNA024414-001: SMU-03 power supply filter board, EMC suppression sub-assembly
3HNA024415-001: SMU-03 DIN rail clip set, mechanical retention hardware
3HNA024416-001: SMU-03 terminal block cover, IP20 finger-safe protective shroud
3HNA024417-001: SMU-03 grounding strap kit, chassis bonding hardware
3HNA024418-001: SMU-03 conformal coating repair kit, selective coating pen set
3HNA024419-001: SMU-03 EEPROM replacement chip, calibration data storage device
DSQC639: IRC5 main computer board, primary interface partner for SMU-03
DSQC643: IRC5 axis computer, coordinates motion data with SMU-03 safety supervision
DSQC662: IRC5 I/O module, digital I/O expansion used alongside SMU-03 safety circuits
SMU-03 modules present specific test challenges due to their dual-channel safety architecture and backplane bus dependency. DriveKNMS applies the following verification protocol to all SMU-03 units prior to dispatch. Each board undergoes visual inspection under 10x magnification for solder joint integrity, capacitor condition, and relay contact wear. Functional testing is performed on a dedicated IRC5 test bench running RobotWare 6.x, verifying SafeMove parameter upload, emergency stop chain continuity across both monitoring channels, and speed supervision output response time (target: <20ms per IEC 62061 SIL2 requirement). The OEW2-25-2MHCP relay module is tested for contact resistance (100MΩ at 500VDC). Backplane connector pins on 3HNA024411-001 are inspected for fretting corrosion and re-plated where necessary. All test results are documented and supplied with the unit on request.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.