Allen-Bradley 1747-SDN DeviceNet Scanner Module – Obsolete SLC 500 Spare Part

Model: 1747-SDN

Series SLC 500
Model 1747-SDN
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Allen-Bradley 1747-SDN DeviceNet Scanner Module – Obsolete SLC 500 Spare Part

When the 1747-SDN DeviceNet Scanner Module fails in a running SLC 500 system, the consequences extend far beyond a single module replacement. This card is the communication backbone between your SLC 500 programmable controller and every DeviceNet field device on the network — drives, sensors, valve manifolds, and I/O blocks. A confirmed failure without a replacement unit on hand forces a choice between two costly outcomes: an unplanned production shutdown measured in days, or a full control system migration that routinely exceeds six figures in engineering, hardware, and commissioning costs. DriveKNMS maintains RFQ-reviewed sourcing status of the 1747-SDN specifically to eliminate that forced choice. Securing a spare now is not a procurement formality — it is a direct hedge against a capital expenditure your budget has not planned for.

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Manufacturer Allen-Bradley (Rockwell Automation)
Part Number 1747-SDN
Series SLC 500
Module Type DeviceNet Scanner Module
Backplane Slot Single slot, SLC 500 I/O chassis
Network Protocol DeviceNet (CAN-based, IEC 62026-3)
Node Address Range 0–63
Baud Rates Supported 125 kbps, 250 kbps, 500 kbps
Max DeviceNet Nodes 63 nodes per scanner
Backplane Current Draw 800 mA @ 5 VDC
Operating Temperature 0°C to 60°C
Product Status Discontinued / Obsolete – No longer manufactured by Rockwell Automation
Compatible Controllers SLC 5/03, SLC 5/04, SLC 5/05
Country of Origin United States

Solving the Discontinued Hardware Crisis

The SLC 500 platform entered end-of-life status years ago, yet tens of thousands of SLC 500-based control systems remain in active production service across food and beverage, automotive, water treatment, and discrete manufacturing facilities worldwide. The 1747-SDN is not a peripheral accessory — it is the single point of integration between the SLC processor and the entire DeviceNet device layer. There is no firmware patch, no software workaround, and no partial substitution that replicates its function without hardware replacement.

Condition & Reliability Assurance

Every 1747-SDN unit processed by DriveKNMS passes a structured 5-step quality verification protocol before it is offered for sale:

  • Step 1 – Visual and Mechanical Inspection: Board-level examination for physical damage, connector pin integrity, and housing condition. Units with bent backplane connectors or cracked housings are rejected at intake.
  • Step 2 – Electrolytic Capacitor Assessment: Age-related capacitor degradation is the primary failure mode in legacy industrial modules. Each unit is assessed for capacitor bulging, leakage, and ESR deviation. Units with suspect capacitors are either reconditioned or removed from inventory.
  • Step 3 – Firmware Version Verification: The installed firmware revision is documented and cross-referenced against known compatibility requirements for SLC 5/03, 5/04, and 5/05 processors. Firmware version is disclosed in the shipment documentation.
  • Step 4 – Pin and Contact Corrosion Check: Backplane edge connector pins are inspected under magnification for oxidation and corrosion. Affected contacts are cleaned to IPC-7711/7721 standards where applicable.
  • Step 5 – Functional Power-On Test: Where test fixtures are available, units undergo a supervised power-on sequence to confirm backplane communication and DeviceNet port initialization prior to shipment.

Key Features for System Maintenance

Q: How do I confirm the unit is genuine and not counterfeit?
A: All units are sourced through documented industrial surplus and decommissioning channels. Rockwell Automation catalog labels, date codes, and serial number formats are verified at intake. Shipment documentation includes the unit's observed condition grade and firmware revision.

Q: Should I buy more than one unit?
A: For any facility running more than one SLC 500 DeviceNet network, holding two units is the standard recommendation. The 1747-SDN is no longer manufactured, and secondary market availability will continue to tighten as installed base units age out. Procurement cost today is materially lower than emergency sourcing cost during a production stoppage.

Q: Can this module work with a ControlLogix or CompactLogix system?
A: No. The 1747-SDN is designed exclusively for the SLC 500 backplane. ControlLogix DeviceNet scanning uses the 1756-DNB module; CompactLogix uses the 1769-SDN. These are separate, non-interchangeable products.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top