Products / Fluke / 719 Series
Fluke 719 Series

Fluke 719100G Electric Pressure Calibrator – Obsolete 719 Series Spare Part

Model: 719100G

Brand Fluke
Series 719 Series
Model 719100G
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Fluke 719100G Electric Pressure Calibrator – Obsolete 719 Series Spare Part

When a Fluke 719100G fails on the calibration bench, the immediate instinct is to replace the entire calibration infrastructure. That instinct carries a price tag. Migrating a process instrumentation calibration workflow built around the Fluke 719 series — including recertification of procedures, retraining of technicians, and revalidation of documented calibration records — routinely costs facilities between $80,000 and $400,000 USD, depending on the scale of the operation and the regulatory environment. A single replacement unit sourced from verified stock eliminates that exposure entirely.

DriveKNMS holds verified inventory of the Fluke 719100G. This is not a catalog listing. Stock is physically on hand and subject to depletion without notice.

Technical Specifications

Parameter Detail
Manufacturer Fluke Corporation
Model Number 719100G
Series Fluke 719 Electric Pressure Calibrator
Pressure Range 0 to 100 psi (gauge)
Pressure Type Gauge pressure
Pump Type Internal electric pump
Country of Origin United States
Discontinuation Status Discontinued – superseded by Fluke 719Pro series
Typical Legacy System Pairing Process calibration loops in DCS environments including Honeywell TDC 3000, Yokogawa CENTUM CS, and ABB Advant OCS installations where 4–20 mA transmitter calibration is performed in-situ

Note: Electrical parameters beyond the above are not published here to avoid inaccuracy. Verified datasheets are available upon request.

Solving the Discontinued Hardware Crisis

The Fluke 719100G occupies a specific operational role that its successors do not replicate without workflow disruption. Facilities that standardized calibration procedures on the 719 series — particularly those operating under ISO 9001, ISO/IEC 17025, or FDA 21 CFR Part 11 frameworks — face a non-trivial revalidation burden when switching calibrator models. Every calibration procedure document that references the 719100G by model number must be revised, reviewed, and re-approved. In regulated industries, that process alone can take months.

Beyond documentation, the 719100G's integrated electric pump design allowed single-technician operation in confined instrument enclosures — a workflow advantage that not all replacement models preserve. Maintenance teams that have built muscle memory and SOPs around this unit face a measurable productivity dip during any transition period.

The lowest-cost path to maintaining calibration program continuity is to hold verified spare units of the 719100G in controlled storage. A single unit in reserve eliminates schedule risk for the next 5 to 10 years of calibration operations, at a fraction of the cost of a procedure revalidation project.

How to extend your calibration asset life by 5–10 years without a system overhaul:

  • Procure a verified spare unit now. The 719100G is no longer manufactured. Secondary market availability will continue to tighten. Units sourced today from inspected stock carry significantly lower risk than units sourced under emergency conditions two years from now.
  • Establish a calibration interval for the calibrator itself. The 719100G requires periodic recalibration against a primary pressure standard. Maintaining this discipline extends the unit's metrological life and catches drift before it affects process measurements.
  • Store the spare in controlled conditions. Pressure calibrators with internal pumps are sensitive to storage temperature and humidity. A climate-controlled instrument store with documented entry/exit logs is the correct approach.
  • Document the spare in your asset register. A spare unit that is not in the asset register does not exist for audit purposes. Register it, assign it a calibration due date, and treat it as a standby instrument.
  • Negotiate a calibration service agreement. Several third-party metrology labs continue to support the Fluke 719 series. Locking in a service agreement now, while technician familiarity with the platform is still current, is preferable to sourcing calibration support reactively.

Condition & Reliability Assurance

Sourcing discontinued instrumentation from unverified channels is a documented source of measurement error and instrument failure. DriveKNMS applies a structured inspection protocol to all Fluke 719100G units before shipment.

  • Step 1 – Visual and mechanical inspection: Housing integrity, connector condition, pump port inspection, and keypad function verification.
  • Step 2 – Internal capacitor assessment: Electrolytic capacitors in the power management circuit are inspected for signs of aging, bulging, or electrolyte leakage. Units with compromised capacitors are not offered for sale.
  • Step 3 – Firmware version verification: The installed firmware version is documented and disclosed. Units with known firmware defects are flagged.
  • Step 4 – Pin and connector corrosion check: All pressure port fittings and electrical connectors are inspected under magnification for oxidation and corrosion. Affected contact surfaces are treated or the unit is rejected.
  • Step 5 – Functional pressure test: The unit is powered and the electric pump is cycled through its operating range. Pressure generation, hold, and bleed functions are verified against expected behavior.

Condition grade and any observed cosmetic wear are disclosed in writing prior to order confirmation. No unit ships without a completed inspection record.

Key Features for System Maintenance

  • Drop-in replacement: The 719100G is a direct physical and functional replacement for any existing 719100G in service. No reconfiguration of the calibration loop is required.
  • No reprogramming required: Calibration procedures referencing the 719100G by model number remain valid. There is no software migration, no procedure revision, and no revalidation triggered by a like-for-like replacement.
  • Avoids engineering requalification costs: Introducing a different calibrator model into a validated calibration program requires formal change control. A same-model replacement does not. This distinction has direct cost implications in pharmaceutical, petrochemical, and power generation facilities.
  • Preserves technician workflow: Technicians trained on the 719100G require no retraining. Operational continuity is maintained from day one of deployment.

FAQ

What warranty applies to a discontinued unit?
DriveKNMS provides a 90-day functional warranty on all inspected units. This covers failure under normal operating conditions. The warranty period begins on the date of shipment. Extended coverage options are available — contact us to discuss.

How do I confirm the unit is genuine and not counterfeit?
All units are sourced through documented supply channels. Serial numbers are verified against known Fluke manufacturing ranges where records are available. The inspection report accompanying each unit includes serial number, firmware version, and condition grade. We do not sell units where provenance cannot be established.

Should I buy more than one unit?
For facilities with more than two 719100G units in active service, holding at least one verified spare is a defensible risk management position. For facilities with a single unit in service, the calculus is straightforward: the cost of a spare unit is a small fraction of the cost of an unplanned calibration program suspension. Long-term spare parts storage for discontinued instrumentation is standard practice in industries where calibration program continuity is a compliance requirement.

Can you source other Fluke 719 series variants?
DriveKNMS maintains sourcing capability across the Fluke 719 series. Contact us with your specific model requirement and we will advise on availability.

© 2026 DriveKNMS. Status: DRAFT

WhatsApp Prefilled Inquiry Email [email protected] Phone +86 18359293191 Top Back To Top