Siemens S31043 Rectifier Modules S31043-K1166-X
Siemens S31043-K1166-X is listed for Controller Cards RFQ review. Confirm quantity, condition and destination before quotation.
Model: 3RT2026-1AG20
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
When a Siemens 3RT2026-1AG20 contactor fails in a legacy motor control center, the immediate question is not where to find a replacement — it is whether the entire control panel must be redesigned. For facilities running SIRIUS-based motor starters integrated into older Siemens S7-300 or S5-series automation architectures, a single failed contactor can cascade into a production stoppage that forces a capital expenditure decision: source the original part, or fund a full panel re-engineering project that routinely exceeds six figures. DriveKNMS maintains RFQ-reviewed sourcing status of the 3RT2026-1AG20 specifically to eliminate that forced choice. This is not a generic substitute. It is the original Siemens SIRIUS contactor, sourced and held for exactly this scenario.
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
| Part Number | 3RT2026-1AG20 |
| Brand | Siemens |
| Series | SIRIUS 3RT2 |
| Product Type | 3-Pole Power Contactor |
| Rated Operational Current (AC-3) | 25 A |
| Motor Rating at 400V AC-3 | 11 kW |
| Coil Voltage | 110 V AC, 50/60 Hz |
| Auxiliary Contacts | 1 NO + 1 NC (integrated) |
| Mounting | DIN rail / screw mounting |
| Country of Origin | Germany |
| Discontinuation Status | Discontinued by Siemens; no direct OEM successor with identical footprint and coil voltage combination |
The 3RT2026-1AG20 was a standard building block in Siemens SIRIUS motor starter assemblies deployed across manufacturing, water treatment, and process industries throughout the 1990s and 2000s. These assemblies were frequently integrated with Siemens S7-300 PLCs, older ET 200 distributed I/O stations, and in some installations, legacy S5-series controllers. The contactor's 110 V AC coil voltage is a specification that does not map cleanly onto current-generation SIRIUS 3RT2 variants without auxiliary transformer modifications — a change that requires panel re-certification in most jurisdictions.
For plant engineering teams, the arithmetic is straightforward. A single motor control center panel containing 12 to 20 of these contactors represents an asset that, if forced into full replacement, carries a re-engineering, procurement, installation, and re-commissioning cost that typically ranges from USD 80,000 to USD 300,000 depending on panel complexity and local labor rates. Sourcing original 3RT2026-1AG20 units at current spare part pricing extends that asset's operational life by 5 to 10 years at a fraction of that cost.
Every 3RT2026-1AG20 unit processed through DriveKNMS undergoes a structured 5-step inspection protocol before it is offered for sale:
Units that do not pass all five steps are not offered for sale. Condition grade (new surplus, tested serviceable, or refurbished) is disclosed at the time of quotation.
How do I know the unit is genuine Siemens and not a counterfeit?
All units are inspected for Siemens markings, date codes, and construction consistency. We do not source from unverified secondary markets. Provenance documentation is available on request for critical applications.
Should I buy more than one unit?
For any system with more than three of these contactors installed, maintaining a minimum of two spare units is a standard risk management practice. The cost of a second spare is negligible relative to the cost of an unplanned production stoppage while a replacement is sourced. For systems where this contactor is in continuous heavy-duty cycling service, a higher buffer is warranted.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.