Technical Dossier

Product Details And Specifications

Siemens 6ED1052-1MD00-0BA6 Display Module – Obsolete LOGO! Spare Part

When a display module on a Siemens LOGO! logic controller fails, the consequences extend far beyond a single component. For facilities running legacy automation built around the LOGO! 0BA6 generation, this module is the human-machine interface that operators depend on for parameter entry, status monitoring, and fault acknowledgment. Its failure does not merely inconvenience — it halts production. Sourcing a certified replacement through standard distribution channels is no longer straightforward: Siemens has transitioned this product line through multiple generations, and 0BA6-series components are increasingly difficult to locate through conventional supply chains.

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Parameter Detail
Part Number 6ED1052-1MD00-0BA6
Manufacturer Siemens
Series LOGO! 0BA6
Function Display and keypad module for LOGO! logic module
Compatible Base Units LOGO! 0BA6 series logic modules (6ED1052-x series)
Country of Origin Germany
Product Status Discontinued / Obsolete – No longer in standard production
Replacement Generation LOGO! 8 (requires hardware and software re-engineering)

Solving the Discontinued Hardware Crisis

The Siemens LOGO! 0BA6 platform was deployed extensively in building automation, water treatment, small-scale process control, and machine OEM applications throughout the 2000s and early 2010s. Many of these installations remain in active service. The display module 6ED1052-1MD00-0BA6 is not a peripheral accessory — it is the primary operator interface for parameter changes and diagnostic readout on standalone LOGO! units without an external HMI.

When this component fails, facilities face a binary choice: locate a compatible replacement, or commit to a full system redesign. For plant managers operating under capital expenditure constraints, the redesign path is rarely viable on short notice. A single unplanned line stoppage lasting 48–72 hours while engineering evaluates upgrade options can cost more than an entire year's worth of preventive spare parts procurement.

How to extend your LOGO! 0BA6 system life by 5–10 years:

Condition & Reliability Assurance

Obsolete components sourced from the secondary market carry inherent risk if not properly evaluated. DriveKNMS applies a structured 5-step quality process to all discontinued Siemens LOGO! display modules before dispatch review:

  1. Visual and mechanical inspection: Full examination of housing integrity, keypad membrane condition, and connector pin alignment. Units with physical damage are rejected at this stage.
  2. Electrolytic capacitor assessment: Aging electrolytic capacitors are a primary failure mode in components of this generation. Each unit is evaluated for capacitor condition; units showing signs of electrolyte leakage or bulging are quarantined.
  3. Connector and pin corrosion check: All interface connectors are inspected under magnification for oxidation, corrosion, and contact deformation. Affected contacts are cleaned or the unit is rejected.
  4. Firmware version verification: Where applicable, firmware markings are documented and cross-referenced against known 0BA6-series compatibility data to ensure the module will operate correctly with target base units.
  5. Functional verification: Units undergo power-on testing and display function verification prior to packaging.

Key Features for System Maintenance

  • Drop-in replacement: The 6ED1052-1MD00-0BA6 installs directly into existing LOGO! 0BA6 base units with no hardware modification.
  • No reprogramming required: Program logic resides in the base unit. Replacing the display module does not affect stored programs or parameter sets.
  • No engineering redesign costs: Unlike a platform migration, a like-for-like display module replacement requires no panel modifications, no software re-engineering, and no revalidation of control logic.
  • Immediate operational restoration: A verified spare on hand converts a critical failure event into a routine maintenance task, measured in minutes rather than days.

How do I know the unit is genuine and not counterfeit?
All units are sourced through documented supply channels. Physical markings, date codes, and construction are verified against known-genuine references. Units that do not pass authentication are not offered for sale.

Should I buy more than one unit?
For facilities with multiple LOGO! 0BA6 installations, holding two to three units is a defensible risk management position. Availability of 0BA6-series components in the secondary market is declining. Units secured today may not be available at any price in 24–36 months.

Can you source other LOGO! 0BA6 components?
Yes. DriveKNMS specializes in discontinued Siemens components across multiple product lines. Contact us with your full bill of materials for a consolidated quotation.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top