Siemens 6ES7134-4GB50-0AB0 Analog Input Module – Obsolete ET 200S Spare Part

Model: 6ES7134-4GB50-0AB0

Brand Siemens
Model 6ES7134-4GB50-0AB0
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens 6ES7134-4GB50-0AB0 Analog Input Module – Obsolete ET 200S Spare Part

RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.

Technical Specifications

Parameter Value
Part Number 6ES7134-4GB50-0AB0
Manufacturer Siemens
Product Family SIMATIC ET 200S
Module Type Analog Input Module
Number of Inputs 2
Input Signal Type Current (0–20 mA / 4–20 mA)
Resolution 13-bit + sign
Supply Voltage 24 V DC (via backplane bus)
Compatible Controllers SIMATIC S7-300, S7-400 via ET 200S IM 151 interface module
Mounting ET 200S terminal module (e.g., TM-E series)
Discontinuation Status Discontinued / Obsolete – no longer available through standard Siemens distribution channels
Country of Origin Germany

Solving the Discontinued Hardware Crisis

The Siemens ET 200S platform was widely deployed across process industries, automotive manufacturing, and utilities throughout the 2000s and 2010s. The 6ES7134-4GB50-0AB0 served as a core analog acquisition point in these distributed I/O architectures, interfacing directly with field transmitters — flow meters, pressure sensors, and temperature loops — that feed real-time data into S7-300 and S7-400 PLCs.

Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.

For plant managers and maintenance engineers operating under capital expenditure constraints, the practical alternative is straightforward: maintain a strategic inventory of critical ET 200S modules. A single 6ES7134-4GB50-0AB0 held in the spare parts cabinet eliminates the risk of an unplanned line stoppage caused by a failed analog input channel. The cost of the spare is a fraction of one hour of lost production at most facilities.

This module is also commonly found in installations alongside the Siemens IM 151-1 and IM 151-3 interface modules, and in systems managed through Siemens SIMATIC PCS 7 distributed control environments. Its removal from active production by Siemens does not reduce its operational importance in the field — it increases it.

Condition & Reliability Assurance

DriveKNMS applies a structured 5-step quality assurance process to all discontinued modules before dispatch review. This protocol is designed specifically for the failure modes common to aging industrial electronics:

  • Step 1 – Visual and Physical Inspection: Full examination of housing integrity, connector pins, and PCB surface. Pin corrosion and oxidation are documented and addressed before any electrical testing begins.
  • Step 2 – Electrolytic Capacitor Assessment: Aging electrolytic capacitors are a primary failure point in modules manufactured over a decade ago. Each unit is evaluated for capacitor condition; units showing signs of bulging, leakage, or ESR deviation are rejected.
  • Step 3 – Firmware Version Verification: Where applicable, firmware revision is confirmed against known compatible versions for S7-300/S7-400 integration. Modules with unverifiable or corrupted firmware states are not released.
  • Step 4 – Functional Electrical Test: Analog input channels are tested under simulated load conditions to verify signal accuracy and channel isolation.
  • Step 5 – Final Documentation and Packaging: Each unit is logged with its test results, condition grade (New / Refurbished-Grade-A), and packaged in anti-static protection for transit.

Key Features for System Maintenance

Q: Can this module be used with TIA Portal?
A: The 6ES7134-4GB50-0AB0 is a STEP 7 Classic (v5.x) era module. It can be used in TIA Portal environments only when the ET 200S station is managed through a legacy STEP 7 hardware configuration. Direct TIA Portal ET 200SP migration is a separate engineering project.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top