Siemens SIMATIC ET 200SP IM 507 Modules: 6ES7507-0RA00-0AB0

Model: 6ES7507-0RA00-0AB0

Brand Siemens
Model 6ES7507-0RA00-0AB0
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens SIMATIC ET 200SP IM 507 Series Technical Notes

The Siemens SIMATIC ET 200SP IM 507 (Interface Module 507) is the central communication backbone of the ET 200SP distributed I/O system, one of the most widely deployed remote I/O platforms in global heavy industry. Installed across petrochemical complexes, nuclear power auxiliary systems, offshore platforms, and continuous-process refineries, the ET 200SP system — anchored by the IM 507 interface module — provides PROFINET-based distributed I/O connectivity to SIMATIC S7-1500 and S7-1500F controllers. Its compact rail-mount form factor, high channel density, and deterministic cycle times make it the reference architecture for process automation engineers specifying new DCS/PLC hybrid topologies. The IM 507 specifically enables the ET 200SP station to operate as a PROFINET IO device, supporting up to 32 I/O modules per station and providing integrated diagnostics, isochronous mode, and shared device functionality.

The Evolution of ET 200SP IM 507 Architecture

The ET 200SP platform was introduced by Siemens in 2012 as the successor to the ET 200S series, addressing the demand for higher packing density and reduced wiring complexity in distributed I/O applications. The IM 507 interface module family was developed specifically to serve as the PROFINET IO device head for ET 200SP stations connected to S7-1500 CPUs.

Early IM 507 variants (circa 2013–2015) supported standard PROFINET IO with RT (Real-Time) communication. Subsequent hardware revisions introduced IRT (Isochronous Real-Time) support, enabling sub-millisecond cycle synchronization required in motion-integrated process lines. The 6ES7507-0RA00-0AB0 variant supports PROFINET IO with RT and IRT, shared device operation (up to two IO controllers), and integrated web server diagnostics — features that were progressively added through firmware generations.

Compatibility considerations are critical for maintenance engineers: IM 507 modules require BaseUnit BU type A0 (6ES7193-6BP20-0DA0 or equivalent) and are not interchangeable with ET 200SP IM 155-6 PN modules without reconfiguration in TIA Portal. Firmware version alignment between the IM 507 and the S7-1500 CPU is mandatory; mismatched GSD file versions are a documented source of station startup failures in brownfield installations.

ET 200SP IM 507 Full Catalog & Functionalities (SKU List)

Interface Modules (IM 507 Family)

  • 6ES7507-0RA00-0AB0: IM 507 PROFINET IO device interface module, RT/IRT, shared device, max 32 I/O modules per station.
  • 6ES7155-6AU01-0BN0: IM 155-6 PN ST, standard PROFINET interface for ET 200SP, predecessor reference platform.
  • 6ES7155-6AU30-0BN0: IM 155-6 PN HF, high-feature PROFINET with MRP, MRPD, isochronous mode.
  • 6ES7155-6AU00-0BN0: IM 155-6 PN BA, basic PROFINET interface, reduced feature set for cost-sensitive applications.

Digital Input Modules (DI)

  • 6ES7131-6BF01-0BA0: DI 8x24VDC ST, 8-channel 24 V DC digital input, standard type, 3.0 ms input delay.
  • 6ES7131-6BH01-0BA0: DI 16x24VDC ST, 16-channel 24 V DC digital input, standard type.
  • 6ES7131-6BF00-0CA0: DI 8x24VDC HF, 8-channel high-feature with diagnostics and isochronous mode.
  • 6ES7131-6TF00-0BB1: DI 8x24VDC SRC BA, source-type input, basic, for PNP sensor wiring.

Digital Output Modules (DO)

  • 6ES7132-6BF01-0BA0: DQ 8x24VDC/0.5A ST, 8-channel 24 V DC digital output, 0.5 A per channel.
  • 6ES7132-6BH01-0BA0: DQ 16x24VDC/0.5A ST, 16-channel digital output, standard type.
  • 6ES7132-6BF00-0CA0: DQ 8x24VDC/0.5A HF, high-feature with diagnostics, substitute value, and isochronous mode.
  • 6ES7132-6HD01-0BB1: DQ 4x24VDC/2A HF, 4-channel high-current output, 2 A per channel, for actuator-heavy applications.

Analog Input Modules (AI)

  • 6ES7134-6GD01-0BA1: AI 4xU/I 2-wire ST, 4-channel analog input, voltage/current, 2-wire transmitter compatible.
  • 6ES7134-6HB00-0BA1: AI Energy Meter 400VAC ST, power measurement module for energy monitoring applications.
  • 6ES7134-6JF00-0CA1: AI 8xU/I HS, 8-channel high-speed analog input, 1 ms conversion time.

Analog Output Modules (AO)

  • 6ES7135-6GB00-0BA1: AQ 2xU/I ST, 2-channel analog output, ±10 V / 0–20 mA, standard type.
  • 6ES7135-6HD00-0BA1: AQ 4xU/I ST, 4-channel analog output, standard type.

Technology & Communication Modules

  • 6ES7138-6CG00-0BA0: CM PTP, point-to-point serial communication module, RS-232/RS-422/RS-485.
  • 6ES7138-6DB00-0BB0: CM IO-Link Master, 4-port IO-Link master module for sensor/actuator integration.

Power / BaseUnit Modules

  • 6ES7193-6BP20-0DA0: BaseUnit BU20-P0+A0+2B, light type, for modules without potential group change.
  • 6ES7193-6BP00-0DA0: BaseUnit BU15-P0+A0+2B, standard type, dark for potential group change.
  • 6ES7138-6AA01-0BA0: PM-E 24VDC ST, power module for load group supply, 24 V DC.

Quality Control for the ET 200SP IM 507 Range

ET 200SP IM 507 modules present specific test challenges due to their integrated PROFINET ASIC, backplane bus controller, and multi-channel diagnostic logic. DriveKNMS applies a structured verification protocol for all IM 507 units prior to dispatch:

  • PROFINET IO enumeration test: Module is connected to a live S7-1500 test rack and enumerated as a PROFINET IO device. Station startup, device name assignment, and IP parameter download are verified against the module's GSD file.
  • Backplane bus integrity check: All 32 I/O module slots are exercised using a standardized I/O module set to verify backplane communication integrity and slot addressing.
  • Firmware version verification: Firmware version is read via TIA Portal online diagnostics and documented. Modules with firmware below V2.0 are flagged for customer notification.
  • Shared device function test: For modules supporting shared device operation, dual-controller enumeration is tested to confirm correct AR (Application Relationship) handling.
  • Thermal cycling: Units are subjected to 0–55°C thermal cycling per IEC 61131-2 environmental class to screen for latent solder joint failures common in refurbished industrial electronics.
  • Visual and mechanical inspection: Backplane connector pins, locking lever, and labeling strip are inspected for wear, corrosion, or mechanical damage.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top