Siemens SIMOVERT 6SE7090-0XX84-0FC0

Model: 6SE7090-0XX84-0FC0

Brand Siemens
Series Pending
Model 6SE7090-0XX84-0FC0
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens SIMOVERT Series Technical Notes

The Evolution of SIMOVERT Architecture

The SIMOVERT MASTERDRIVES platform (6SE70) was developed as a successor to the earlier SIMOVERT P and SIMOVERT F series. The initial 6SE70 generation used analog reference inputs and RS-485 serial communication. By the mid-1990s, Siemens introduced the CUVC board with full closed-loop vector control, enabling torque-regulated operation without encoder feedback. The subsequent CUMC variant added motion control functionality for positioning applications. Communication options expanded to include PROFIBUS-DP via the CBP2 adapter (6SE7090-0XX84-0FF5) and DeviceNet via the CBD board. The 6SE7090-0XX84-0FC0 is classified as an accessory/option board within this ecosystem — specifically a technology option or communication board depending on the firmware variant installed. Siemens officially discontinued active production of the core 6SE70 platform, transitioning customers toward the SINAMICS G150 and S150 series. However, the installed base remains extensive, and spare parts support is required through at least 2030 under extended lifecycle agreements at many facilities.

SIMOVERT Full Catalog & Functionalities (SKU List)

The following SKUs represent verified components within the Siemens SIMOVERT 6SE70 platform. Each entry is classified by functional category.

Control Units (CU)

  • 6SE7021-0EP50: CUVC control unit, closed-loop vector control, 3.0 kW frame size B
  • 6SE7023-4TC51: CUVC control unit, 18.5 kW, frame size C, USS/PROFIBUS ready
  • 6SE7031-5EF60: CUVC control unit, 132 kW, frame size F, encoder interface integrated
  • 6SE7032-6EG60: CUVC control unit, 160 kW, frame size G, dual encoder input
  • 6SE7035-1EK60: CUVC control unit, 250 kW, frame size K, high-performance torque control

Option & Accessory Boards

  • 6SE7090-0XX84-0FC0: Technology option board, SIMOVERT MASTERDRIVES accessory, firmware-dependent function expansion
  • 6SE7090-0XX84-0AB0: Operator panel interface adapter, local/remote parameter access
  • 6SE7090-0XX84-0FF5: CBP2 PROFIBUS-DP communication board, 12 Mbit/s, DPV1 support
  • 6SE7090-0XX84-0FE0: CBD DeviceNet communication board, 500 kbit/s, explicit messaging
  • 6SE7090-0XX84-0KA0: SCI1 serial interface board, RS-232/RS-485, USS protocol
  • 6SE7090-0XX84-0BC0: ADB analog/digital I/O expansion board, 4AI/4AO/8DI/4DO

Power Sections & Inverter Modules

  • 6SE7022-6EC61: Compact inverter, 11 kW, 400 V, frame size C, integrated rectifier
  • 6SE7026-0ED61: Compact inverter, 30 kW, 400 V, frame size D, IP20
  • 6SE7031-2EF60: Compact inverter, 55 kW, 400 V, frame size F, forced air cooling
  • 6SE7033-2EG60: Compact inverter, 160 kW, 400 V, frame size G, liquid cooling option
  • 6SE7036-0EK60: Compact inverter, 315 kW, 400 V, frame size K, cabinet installation

Rectifier / Active Front End

  • 6SE7031-2HF60: Active infeed converter, 55 kW, regenerative braking, low harmonic distortion
  • 6SE7033-7TG60: Active infeed converter, 200 kW, IGBT-based, unity power factor

Braking Modules

  • 6SE7023-2ES87-2DC0: Braking module, 15 kW continuous, 45 kW peak, external resistor required
  • 6SE7031-2ES87-2DC0: Braking module, 55 kW continuous, frame size F, integrated chopper

Sourcing Hard-to-Find & Obsolete SIMOVERT Parts

Q: How is condition confirmed before quotation?
A: Available condition, photos, test records and documentation are checked according to the requested model and sourcing channel before a formal RFQ response.

Quality Control for the SIMOVERT Range

Q: How are RFQ terms confirmed?
A: Quantity, required condition, documentation needs, destination and sourcing route are confirmed during RFQ review before quotation.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top