Siemens S30810-Q2224-X000-07: HiPath Station Line Module

Model: S30810-Q2224-X000-07

Brand Siemens
Series Pending
Model S30810-Q2224-X000-07
RFQ-ready model route Obsolete and surplus sourcing Export follow-up by model list

Product Overview

Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.

Datasheet Preview

Datasheet Preview

Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.

Request Full Manual

Commercial Path

Use This Page To Confirm The Model, Then Move To RFQ

Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.

Technical Dossier

Product Details And Specifications

Siemens S30810-Q2224-X Series Technical Notes

The Siemens S30810-Q2224-X series represents a family of station line interface modules deployed within the Siemens HiPath 4000 and OpenScape 4000 private branch exchange (PABX) platforms. These modules serve as the physical and logical interface between the central switching fabric and individual analog or digital subscriber endpoints. Installed across telecommunications infrastructure in chemical processing facilities, nuclear power stations, petroleum refineries, airport operations centers, and large-scale manufacturing campuses, the S30810-Q2224-X line modules are embedded in mission-critical voice communication backbones where system uptime is non-negotiable.

The HiPath 4000 platform, for which this module family was designed, has been deployed in over 60 countries and remains operational in thousands of enterprise and industrial sites. The S30810-Q2224-X000-07 specifically functions as a ZSYS station line module, providing subscriber loop connectivity with integrated line supervision, ringing injection, and codec processing. Its role within the HiPath shelf architecture is to terminate analog subscriber lines and present them to the system bus in a format compatible with the central call processing unit.

The Evolution of S30810-Q2224-X Architecture

The V3 and V4 platform generations (2005–2012) introduced enhanced firmware programmability, allowing line parameters such as loop current, ringing frequency, and impedance matching to be configured via the HiPath 4000 Manager software rather than hardware jumpers. The S30810-Q2224-X000-07 variant corresponds to this generation, identified by the hardware revision suffix -07, which denotes a specific PCB revision with updated line driver ICs and improved EMC shielding.

S30810-Q2224-X Full Catalog & Functionalities (SKU List)

The following SKUs represent verified part numbers within the Siemens S30810-Q2224-X and closely related station/trunk line module families for HiPath 4000 and OpenScape 4000 platforms. Each entry reflects a distinct hardware configuration or revision.

Analog Station Line Modules (SLMA/SLMO)

  • S30810-Q2224-X000-07: ZSYS 8-port analog station line module, HW revision 07, HiPath 4000 shelf-compatible.
  • S30810-Q2224-X100: ZSYS analog station line module, HW revision 100, updated line driver variant.
  • S30810-Q2224-X200: ZSYS analog station line module with extended temperature tolerance for industrial environments.
  • S30810-Q2225-X100: SLMA 8-port analog subscriber line module, standard loop current configuration.
  • S30810-Q2225-X200: SLMA analog line module, high-impedance variant for long subscriber loop distances.
  • S30810-Q2226-X100: SLMO 8-port analog line module with on-board message waiting indicator (MWI) support.
  • S30810-Q2226-X200: SLMO analog line module, revised codec chipset for improved voice quality metrics.

Digital Station Line Modules (SLMD/DIUT)

  • S30810-Q2913-X100: DIUT2 digital line module, ISDN BRI U-interface, 4-port configuration for HiPath 4000.
  • S30810-Q2913-X200: DIUT2 digital line module, revised firmware for OpenScape 4000 V6+ compatibility.
  • S30810-Q2943-X100: SLMD 8-port digital station line module, corDECT/DECT base station interface.
  • S30810-Q2943-X200: SLMD digital line module, updated FPGA logic for enhanced synchronization stability.

Trunk Line Modules (LTUC/STLS)

  • S30810-Q2935-X100: LTUC analog trunk line module, loop-start/ground-start configurable, 4-port.
  • S30810-Q2935-X200: LTUC trunk module with integrated call progress tone detection.
  • S30810-Q2936-X100: STLS E1/T1 digital trunk module, 30B+D channel capacity, HiPath 4000 shelf.
  • S30810-Q2936-X200: STLS E1 trunk module, revised line interface for improved jitter tolerance.

Power and Auxiliary Modules

  • S30810-Q2100-X100: Shelf power supply module, 48V DC output, HiPath 4000 standard shelf.
  • S30810-Q2101-X100: Redundant power supply module for HiPath 4000 high-availability shelf configurations.

Sourcing Hard-to-Find & Obsolete S30810-Q2224-X Parts

Customers requiring specific hardware revision levels (e.g., -07 suffix as in S30810-Q2224-X000-07) for firmware compatibility reasons can specify revision requirements at the time of inquiry. DriveKNMS will confirm revision availability prior to order confirmation.

Quality Control for the S30810-Q2224-X Range

Station line modules in the S30810-Q2224-X family present specific test challenges due to their integration of analog subscriber line interface circuits (SLICs), codec ASICs, and backplane bus transceivers on a single PCB. DriveKNMS applies the following test protocol to all S30810-series units prior to dispatch:

  • Backplane bus continuity verification: All edge connector pins are tested for continuity and correct impedance against reference values for the HiPath 4000 shelf bus specification.
  • SLIC functional test: Each subscriber line port is exercised through on-hook, off-hook, ringing, and loop-current measurement states using a calibrated line simulator.
  • Codec loopback test: Voice path integrity is confirmed via digital loopback at the codec level, verifying signal-to-noise ratio within Siemens-specified limits.
  • Firmware revision identification: Onboard EEPROM is read to confirm firmware version and hardware revision suffix, ensuring compatibility documentation accuracy.
  • Thermal stress screening: Units are operated at elevated ambient temperature (55°C) for a minimum of 2 hours to screen for latent component failures prior to shipment.
  • Visual and mechanical inspection: PCB surface, connector integrity, and component seating are inspected under magnification. Units with evidence of prior rework are documented and disclosed.

Continue The Model Path

Use system, brand and series routes to compare related published models.

Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.

WhatsApp Prefilled Inquiry Email sale@driveknms.com Phone +86 18359293191 Top Back To Top