Allen-Bradley 1746-IO12 Combination I/O Module – Obsolete SLC 500 Spare Part
Allen-Bradley 1746-IO12 is listed for SLC 500 RFQ review. Confirm quantity, condition and destination before quotation.
Model: 1734-IE2V
Product Overview
Commercial availability is handled through direct RFQ, model verification and export-oriented follow-up rather than public cart checkout.
Datasheet Preview
Use attached product manuals when available. If the manual is not public yet, request the full file directly through RFQ.
Commercial Path
Product pages on DRIVEKNMS are designed to verify model, brand and series first, then move the buyer into one clean quotation path.
Technical Dossier
RFQ support for obsolete parts: Send the model number, required quantity and destination so DriveKNMS can confirm sourcing options before quotation.
| Parameter | Value |
|---|---|
| Part Number | 1734-IE2V |
| Series | POINT I/O |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Module Type | 2-Channel Analog Voltage Input |
| Input Signal Range | ±10V DC (voltage mode) |
| Resolution | 16-bit |
| Communication | POINT I/O backplane (1734 series adapter required) |
| Power Consumption | Supplied via POINT I/O backplane |
| Compatibility | ControlLogix, CompactLogix, FlexLogix via 1734 adapter |
| Product Status | Discontinued / Obsolete – No longer manufactured by Rockwell Automation |
| Country of Origin | United States |
Note: Electrical parameters are provided based on published Rockwell Automation documentation. Parameters not confirmed by official documentation are intentionally omitted to preserve data integrity.
The Allen-Bradley 1734-IE2V was designed as part of the POINT I/O modular distributed I/O platform — a system architecture that became deeply embedded in process and discrete manufacturing environments throughout the 2000s and 2010s. Its 2-channel voltage input configuration made it a standard component in analog signal acquisition tasks: pressure transducer monitoring, flow measurement, temperature signal conditioning, and position feedback loops.
Rockwell Automation has since transitioned its product roadmap toward newer I/O platforms. The 1734-IE2V is no longer in active production. For facilities that built their control architecture around POINT I/O, this creates a structural maintenance problem: the installed base remains operational, but the supply chain for replacement components has contracted sharply.
For plant managers facing pressure to justify continued operation of legacy Allen-Bradley systems: the economic case for a targeted spare parts program is straightforward. The capital cost of maintaining a curated inventory of critical POINT I/O modules — including the 1734-IE2V — is measurably lower than the cost of an accelerated migration driven by an unplanned component failure.
Sourcing obsolete industrial components carries inherent risk. DriveKNMS applies a structured 5-step quality process to every 1734-IE2V unit before it is offered for sale:
Step 1 – Visual and Physical Inspection: Each unit is examined for housing cracks, connector damage, label integrity, and evidence of prior field modification or repair.
Step 2 – Electrolytic Capacitor Assessment: Aging electrolytic capacitors are a primary failure mode in modules that have been stored or lightly used over extended periods. Units showing capacitor bulge, leakage, or ESR deviation are quarantined.
Step 3 – Pin and Connector Integrity Check: Backplane connector pins are inspected under magnification for corrosion, deformation, and contamination. Corroded pins are a common cause of intermittent communication faults in POINT I/O systems.
Step 4 – Firmware Version Verification: Where accessible, firmware revision is documented and cross-referenced against known compatibility requirements for common ControlLogix and CompactLogix configurations.
Step 5 – Functional Verification: Units are powered and tested for basic communication and channel response prior to packaging.
Units that do not pass all five stages are not listed for sale. Condition grade (New Surplus, Refurbished, or Used-Tested) is disclosed at point of inquiry.
The 1734-IE2V is a direct drop-in replacement for any existing 1734-IE2V position within a POINT I/O rack. No hardware redesign is required. No PLC reprogramming is necessary — the module identity is recognized automatically by the existing I/O configuration in Studio 5000 or RSLogix 5000. No field wiring changes are needed beyond the standard module swap procedure.
Q: How do I know the unit is genuine and not counterfeit?
A: All units are sourced through established industrial surplus and distribution channels. Physical authenticity markers — including label format, housing construction, and connector specifications — are verified against known-good reference units. We do not source from unverified secondary markets.
Q: Can you source related POINT I/O components?
A: Yes. DriveKNMS actively sources the broader 1734 series, including adapters (1734-AENT, 1734-ADNX), power distribution modules, and terminal bases. Contact us with your full bill of materials for a consolidated sourcing inquiry.
Continue The Model Path
Move from this exact model into the matching system hub, brand archive, model-family archive or lifecycle sourcing route before sending a final RFQ list.